Intra- and inter-rater reliability of neutral head position and target head position tests in patients with and without neck pain

被引:51
|
作者
Alahmari, Khalid [1 ]
Reddy, Ravi Shankar [1 ]
Silvian, Paul [1 ]
Ahmad, Irshad [1 ]
Nagaraj, Venkat [1 ]
Mahtab, Mohammad [1 ]
机构
[1] King Khalid Univ, Coll Appl Med Sci, Dept Phys Therapy, Abha, Saudi Arabia
关键词
Cervical spine; Physical therapy; Assessment tools; Joint position sense; CERVICOCEPHALIC KINESTHETIC SENSIBILITY; WHIPLASH-ASSOCIATED DISORDERS; MEASUREMENT TOOLS; RELOCATION TEST; CERVICAL RANGE; SENSE; MOTION; INDIVIDUALS; REPRODUCIBILITY; ASSOCIATION;
D O I
10.1016/j.bjpt.2017.05.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cervical proprioception is a common term used in neck rehabilitation, and it is examined using neutral head position (NHP) and target head position (THP) tests. Objective: To investigate intra- and inter-rater reliability of the NHP and THP tests in patients with neck pain and in healthy controls. Methods: The intra-rater (between-day) and inter-rater (within-day) reliability of the NHP and THP tests were assessed in 36 patients with neck pain and 33 healthy subjects. NHP testing was evaluated in cervical extension, while THP testing was evaluated in six directions of cervical motion: cervical flexion, extension, side bending right, side bending left, rotation right, and rotation left. Results: The intra-rater reliability for the NHP tests had intraclass correlation coefficient (ICC) values of 0.74-0.78 and a standard error of measurement (SEM) of 1.78-1.88; the THP tests had ICC values of 0.70-0.83 and SEM of 1.45-2.45. Likewise, inter-rater reliability for NHP had ICC values of 0.74-0.79 and SEM of 1.79-1.87. For the THP test, the inter-rater reliability had ICC values of 0.62-0.84 and SEM of 1.50-2.23. Conclusion: Intra- and inter-rater reliability ranged from good to very good agreement both for NHP and for THP tests of cervical proprioception. (C) 2017 Associacao Brasileira de Pesquisa e Pos-Graduacao em Fisioterapia. Published by Elsevier Editora Ltda. All rights reserved.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 42 条
  • [21] Test-retest, intra- and inter-rater reliability of the reactive balance test in healthy recreational athletes
    Tassignon, Bruno
    Verschueren, Jo
    De Wachter, Jonas
    Maricot, Alexandre
    De Pauw, Kevin
    Verhagen, Evert
    Meeusen, Romain
    PHYSICAL THERAPY IN SPORT, 2020, 46 : 47 - 53
  • [22] Cervical joint position sense: an intra- and inter-examiner reliability study
    Strimpakos, N
    Sakellari, V
    Gioftsos, G
    Kapreli, E
    Oldham, J
    GAIT & POSTURE, 2006, 23 (01) : 22 - 31
  • [23] Quantitative measurements of forward head in college-aged students: A conformational study of intra-rater and inter-rater reliability of a novel Posture Measuring Device
    Gray, Kurt
    Dalal, Rajiv
    Weaver, Jullet Davis
    Randolph, Saungaylia
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2021, 26 : 233 - 237
  • [24] Intra- and inter-rater reliability of 3D passive intervertebral motion in subjects with non-specific neck pain assessed by physical therapy students: A pilot study
    Rossettini, Giacomo
    Rondoni, Angie
    Lovato, Tommaso
    Strobe, Marco
    Verze, Elisa
    Vicentini, Marco
    Testa, Marco
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2017, 30 (01) : 85 - 99
  • [25] Vibration sensibility of the median nerve in a population with chronic whiplash associated disorder: Intra- and inter-rater reliability study
    Tyros, I.
    Soundy, A.
    Heneghan, N. R.
    MANUAL THERAPY, 2016, 25 : 81 - 86
  • [26] Mechanical Properties of Muscles around the Shoulder in Breast Cancer Patients: Intra-rater and Inter-rater Reliability of the MyotonPRO
    Yeo, Seung Mi
    Kang, Hyojeong
    An, Soyeon
    Cheong, Inyae
    Kim, Yoon
    Hwang, Ji Hye
    PM&R, 2020, 12 (04) : 374 - 381
  • [27] Head-Eye movement control tests in patients with chronic neck pain; Inter-observer reliability and discriminative validity
    Eveline Della Casa
    Jutta Affolter Helbling
    André Meichtry
    Hannu Luomajoki
    Jan Kool
    BMC Musculoskeletal Disorders, 15
  • [28] Intra- and inter-rater reliability for the measurement of the cross-sectional area of ankle tendons assessed by magnetic resonance imaging
    Mansur, Henrique
    Estanislau, Guilherme
    de Noronha, Marcos
    Marqueti, Rita de Cassia
    Fachin-Martins, Emerson
    Quagliotti Durigan, Joao Luiz
    ACTA RADIOLOGICA, 2022, 63 (04) : 481 - 488
  • [29] Intra- and inter-rater reliability of the rate of force development of hip abductor muscles measured by hand-held dynamometer
    Takeda, Kazuya
    Tanabe, Shigeo
    Koyama, Soichiro
    Nagai, Tomoko
    Sakurai, Hiroaki
    Kanada, Yoshikiyo
    Shomoto, Koji
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2018, 22 (01) : 19 - 24
  • [30] Position accuracy and electromyographic responses during head reposition in young adults with chronic neck pain
    Cheng, Chih-Hsiu
    Wang, Jaw-Lin
    Lin, Jiu-Jenq
    Wang, Shwu-Fen
    Lin, Kwan-Hwa
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (05) : 1014 - 1020