Amperometric detection in TMB/HRP-based assays

被引:118
作者
Fanjul-Bolado, P [1 ]
González-Garía, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
horseradish peroxidase; 3,3 ' 5,5 '-tetramethylbenzidine; screen-printed carbon electrode; flow injection analysis; ELISA;
D O I
10.1007/s00216-005-3084-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
3,3', 5,5'- Tetramethylbenzidine (TMB) is the most commonly used chromogen for horseradish peroxidase (HRP) and so its performance as an electrochemical substrate was evaluated. Measurements of HRP activity in solution were carried out by using an amperometric detector coupled to a flow injection analysis (FIA) system. The enzymatic product was easily detected at a potential of +0.1 V ( vs. Ag-pseudoreference electrode) at a bare screen-printed electrode placed in a homemade electrochemical. ow cell. A high. ow rate (4.3 mL min(-1)) of 0.5 M H2SO4 was used to obtain repeatable signals and a short analysis time. The detection limit achieved after 15 min of incubation was 2 mu 10(-14) M of HRP. The applicability of the amperometric detector to ELISAs was demonstrated by using a commercially available kit for the quanti. cation of interleukin- 6 (IL- 6) without modifying the kit manufacturer's protocol or the reagents for this test.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 25 条
[1]   Enzymatic determination of phenols using peanut peroxidase [J].
Bagirova, NA ;
Shekhovtsova, TN ;
van Huystee, RB .
TALANTA, 2001, 55 (06) :1151-1164
[2]  
BARD AJ, 1969, ELECTROCHEMISTRY SOL
[3]   VOLTAMMETRIC DETERMINATION OF BENZIDINE AND ITS DERIVATIVES, AT A GLASSY-CARBON ELECTRODE [J].
BAREK, J ;
BERKA, A ;
TOCKSTEINOVA, Z ;
ZIMA, J .
TALANTA, 1986, 33 (10) :811-815
[4]  
Bos E S, 1981, J Immunoassay, V2, P187, DOI 10.1080/15321818108056977
[5]   A new electrochemical enzyme-linked immunosorbent assay for the screening of macrolide antibiotic residues in bovine meat [J].
Draisci, R ;
delli Quadri, F ;
Achene, L ;
Volpe, G ;
Palleschi, L ;
Palleschi, G .
ANALYST, 2001, 126 (11) :1942-1946
[6]  
Eichorn G.L., 1973, INORGANIC BIOCH, V2
[7]   Voltammetric determination of alkaline phosphatase and horseradish peroxidase activity using 3-indoxyl phosphate as substrate -: Application to enzyme immunoassay [J].
Fanjul-Bolado, P ;
González-García, MB ;
Costa-García, A .
TALANTA, 2004, 64 (02) :452-457
[8]   A stable and highly sensitive 3,3′,5,5′-tetramethylbenzidine-based substrate reagent for enzyme-linked immunosorbent assays [J].
Frey, A ;
Meckelein, B ;
Externest, D ;
Schmidt, MA .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 233 (1-2) :47-56
[9]  
GALLATI H, 1985, J CLIN CHEM CLIN BIO, V23, P453
[10]   A MEMS based amperometric detector for E-Coli bacteria using self-assembled monolayers [J].
Gau, JJ ;
Lan, EH ;
Dunn, B ;
Ho, CM ;
Woo, JCS .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :745-755