Fast determination of anthocyanins in red grape musts by Fourier transform mid-infrared spectroscopy and partial least squares regression

被引:16
作者
Rasines-Perea, Z. [1 ]
Prieto-Perea, N. [1 ]
Romera-Fernandez, M. [1 ]
Berrueta, L. A. [1 ]
Gallo, B. [1 ]
机构
[1] Univ Basque Country, Fac Ciencia & Tecnol, Dept Quim Analit, Bilbao 48080, Spain
关键词
Grape musts; Anthocyanins; Wine color; FT-IR; HPLC-DAD; PLS; FT-IR SPECTROSCOPY; INFRARED-SPECTROSCOPY; MULTIVARIATE-ANALYSIS; PHENOLIC-COMPOUNDS; WINE ANALYSIS; COPIGMENTATION; CLASSIFICATION; SPECTROMETRY; COLOR; REFLECTANCE;
D O I
10.1007/s00217-014-2394-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The viability of using the Fourier transform mid-infrared spectroscopy matched with partial least squares regression (PLS-R) for the determination of 12 anthocyanins (five non-acylated, three acetylated, three p-coumaroylated and one caffeoylated 3-O-glucosides) in red grapes musts has been studied. Four different PLS regression models were built using 257 samples of grape musts of three harvests, and the prediction of the anthocyanin concentrations using these models was evaluated by internal and external validation sample sets. Cross-validation errors between 9.4 and 30.6 % were attained for major anthocyanins. The major one, malvidin-3-O-glucoside (range of concentrations between 58.78 and 202.76 mg/L), showed standard errors of calibration between 9.01 and 21.12 mg/L. Standard prediction errors for an external validation set including must samples of a new harvest were quite high (between 9.55 and 56.16 %), but somewhat lower (14.91-40.75 %) when considering the regression model including musts of the three harvest. However, good efficiency was observed when using predicted values to order the different musts according to increasing anthocyanin concentration. A correction of FT-IR predicted values should be introduced in order to have more exact absolute values. The proposed method is quick and simple and can be easily implemented for routine winery control of musts and to be used as a quality parameter of harvested grape in terms of their potential contribution to wine color.
引用
收藏
页码:897 / 908
页数:12
相关论文
共 36 条
[21]  
Macho S., 2002, THESIS U ROVIRA VIRG
[22]   THE MECHANISM OF COPIGMENTATION OF ANTHOCYANINS IN AQUEOUS-SOLUTIONS [J].
MAZZA, G ;
BROUILLARD, R .
PHYTOCHEMISTRY, 1990, 29 (04) :1097-1102
[23]  
Moreira J.L., 2002, Ciencia Tec. Vitiv. N.˚17, P27
[24]   Spectroscopic interferences in fourier transform infrared wine analysis [J].
Moreira, JL ;
Santos, L .
ANALYTICA CHIMICA ACTA, 2004, 513 (01) :263-268
[25]  
Naes T. E. A., 2004, Interpreting PCR and PLS solutions. A UserFriendly Guide to Multivariate Calibration and Classification
[26]   Principal component analysis applied to Fourier transform infrared spectroscopy for the design of calibration sets for glycerol prediction models in wine and for the detection and classification of outlier samples [J].
Nieuwoudt, HH ;
Prior, BA ;
Pretorius, IS ;
Manley, M ;
Bauer, FF .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (12) :3726-3735
[27]   Application of FT-IR spectroscopy to the characterisation and classification of wines, brandies and other distilled drinks [J].
Palma, M ;
Barroso, CG .
TALANTA, 2002, 58 (02) :265-271
[28]   Application of FT-MIR spectrometry in wine analysis [J].
Patz, CD ;
Blieke, A ;
Ristow, R ;
Dietrich, H .
ANALYTICA CHIMICA ACTA, 2004, 513 (01) :81-89
[29]   Direct determination of organic acids in wine and wine-derived products by Fourier transform infrared (FT-IR) spectroscopy and chemometric techniques [J].
Regmi, U. ;
Palma, M. ;
Barroso, C. G. .
ANALYTICA CHIMICA ACTA, 2012, 732 :137-144
[30]   Feasibility study of FT-MIR spectroscopy and PLS-R for the fast determination of anthocyanins in wine [J].
Romera-Fernandez, M. ;
Berrueta, L. A. ;
Garmon-Lobato, S. ;
Gallo, B. ;
Vicente, F. ;
Moreda, J. M. .
TALANTA, 2012, 88 :303-310