Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry

被引:41
作者
Zhou, Hui [1 ]
Wang, Yuesong [1 ]
Gatcombe, Matthew [1 ]
Farris, Jacob [1 ]
Botelho, Julianne C. [1 ]
Caudill, Samuel P. [1 ]
Vesper, Hubert W. [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Sci Lab, Clin Chem Branch, 4770 Buford Hwy NE, Atlanta, GA 30341 USA
关键词
CDC HoSt; Estradiol; Testosterone; Hormone; Serum; LC-MS/MS; SOCIETY POSITION STATEMENT; LC-MS/MS; SIMULTANEOUS QUANTITATION; BIOLOGICAL VARIATION; HUMAN PLASMA; ASSAY; MEN; RECOMMENDATIONS; HORMONES; ESTRONE;
D O I
10.1007/s00216-017-0529-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.
引用
收藏
页码:5943 / 5954
页数:12
相关论文
共 49 条
[41]   USE OF CYCLODEXTRINS FOR PREPURIFICATION OF PROGESTERONE AND TESTOSTERONE FROM HUMAN SERUM PRIOR TO DETERMINATION WITH ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
THIENPONT, LM ;
DEBRABANDERE, VI ;
STOCKL, D ;
DELEENHEER, AP .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4116-4119
[42]   High variability in serum estradiol measurements in men and women [J].
Vesper, Hubert W. ;
Botelho, Julianne C. ;
Vidal, Meghan L. ;
Rahmani, Yasamin ;
Thienpont, Linda M. ;
Caudill, Samuel P. .
STEROIDS, 2014, 82 :7-13
[43]   Standardization of testosterone measurements in humans [J].
Vesper, Hubert W. ;
Botelho, Julianne Cook .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) :513-519
[44]   Interlaboratory comparison study of serum total testoserone measurements performed by mass spectrometry methods [J].
Vesper, Hubert W. ;
Bhasin, Shalender ;
Wang, Christina ;
Tai, Susan S. ;
Dodge, Larry A. ;
Singh, Ravinder J. ;
Nelson, Judie ;
Ohorodnik, Susan ;
Clarke, Nigel J. ;
Salameh, Wael A. ;
Parker, C. Richard, Jr. ;
Razdan, Raj ;
Monsell, Elizabeth A. ;
Myers, Gary L. .
STEROIDS, 2009, 74 (06) :498-503
[45]   Development and validation of LC-MS/MS method for quantification of bisphenol A and estrogens in human plasma and seminal fluid [J].
Vitku, Jana ;
Chlupacova, Tereza ;
Sosvorova, Lucie ;
Hampl, Richard ;
Hill, Martin ;
Heracek, Jiri ;
Bicikova, Marie ;
Starka, Luboslav .
TALANTA, 2015, 140 :62-67
[46]   Measurement of total serum testosterone in adult men:: Comparison of current laboratory methods versus liquid chromatography-tandem mass spectrometry [J].
Wang, C ;
Catlin, DH ;
Demers, LM ;
Starcevic, B ;
Swerdloff, RS .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (02) :534-543
[47]   Total testosterone quantitative measurement in serum by LC-MS/MS [J].
Wang, Yuesong ;
Gay, Gabrielle D. ;
Botelho, Julianne Cook ;
Caudill, Samuel P. ;
Vesper, Hubert W. .
CLINICA CHIMICA ACTA, 2014, 436 :263-267
[48]   Performance Criteria for Testosterone Measurements Based on Biological Variation in Adult Males: Recommendations from the Partnership for the Accurate Testing of Hormones [J].
Yun, Yeo-Min ;
Botelho, Julianne Cook ;
Chandler, Donald W. ;
Katayev, Alex ;
Roberts, William L. ;
Stanczyk, Frank Z. ;
Vesper, Hubert W. ;
Nakamoto, Jon M. ;
Garibaldi, Luigi ;
Clarke, Nigel J. ;
Fitzgerald, Robert L. .
CLINICAL CHEMISTRY, 2012, 58 (12) :1703-1710
[49]   Simultaneous quantitation of endogenous estrone, 17β-estradiol, and estriol in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry for clinical laboratory applications [J].
Zhang, Qiaoxuan ;
Han, Liqiao ;
Wang, Jianbing ;
Lin, Haibiao ;
Ke, Peifeng ;
Zhuang, Junhua ;
Huang, Xianzhang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (10) :2627-2638