Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry

被引:41
作者
Zhou, Hui [1 ]
Wang, Yuesong [1 ]
Gatcombe, Matthew [1 ]
Farris, Jacob [1 ]
Botelho, Julianne C. [1 ]
Caudill, Samuel P. [1 ]
Vesper, Hubert W. [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Sci Lab, Clin Chem Branch, 4770 Buford Hwy NE, Atlanta, GA 30341 USA
关键词
CDC HoSt; Estradiol; Testosterone; Hormone; Serum; LC-MS/MS; SOCIETY POSITION STATEMENT; LC-MS/MS; SIMULTANEOUS QUANTITATION; BIOLOGICAL VARIATION; HUMAN PLASMA; ASSAY; MEN; RECOMMENDATIONS; HORMONES; ESTRONE;
D O I
10.1007/s00216-017-0529-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.
引用
收藏
页码:5943 / 5954
页数:12
相关论文
共 49 条
[1]  
[Anonymous], 2012, EP17A2 CLSI
[2]  
Becker D, 1992, NIST Special Publication, V829
[3]   Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS) [J].
Boggs, Ashley S. P. ;
Bowden, John A. ;
Galligan, Thomas M. ;
Guillette, Louis J., Jr. ;
Kucklick, John R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (15) :4179-4190
[4]   Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum [J].
Botelho, Julianne Cook ;
Ribera, Ashley ;
Cooper, Hans C. ;
Vesper, Hubert W. .
ANALYTICAL CHEMISTRY, 2016, 88 (22) :11123-11129
[5]   Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry Candidate Reference Method for Total Testosterone in Human Serum [J].
Botelho, Julianne Cook ;
Shacklady, Christopher ;
Cooper, Hans C. ;
Tai, Susan S. -C. ;
Van Uytfanghe, Katleen ;
Thienpont, Linda M. ;
Vesper, Hubert W. .
CLINICAL CHEMISTRY, 2013, 59 (02) :372-380
[6]   Multi-rule quality control for the age-related eye disease study [J].
Caudill, Salntlel P. ;
Schleicher, Rosemary L. ;
Pirkle, James L. .
STATISTICS IN MEDICINE, 2008, 27 (20) :4094-4106
[7]   Estrogen and bone health in men and women [J].
Cauley, Jane A. .
STEROIDS, 2015, 99 :11-15
[8]   Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: Validation of a method for routine clinical practice [J].
Cawood, ML ;
Field, HP ;
Ford, CG ;
Gillingwater, S ;
Kicman, A ;
Cowan, D ;
Barth, JH .
CLINICAL CHEMISTRY, 2005, 51 (08) :1472-1479
[9]  
CLSI, 2014, EP5A3 CLSI
[10]  
CLSI, 2014, C62A CLSI