Contactless measurement of physiological parameters

被引:0
|
作者
Ciattaglia, Gianluca [1 ]
Senigagliesi, Linda [1 ]
De Santis, Adelmo [1 ]
Ricciuti, Manola [1 ]
机构
[1] Polytech Univ Marche, Dept Informat Engn, Ancona, Italy
关键词
contactless sensors; mmWave radar; heart rate; respiration rate;
D O I
10.1109/icce-berlin47944.2019.8966140
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The possibility of remote measurement of vital parameters makes it possible to implement telemedicine systems. However these systems are of particular interest for subjects who, due to age or pathologies, are weak and fragile. For these subjects, the management of devices for measuring vital parameters that must be appropriately positioned in contact with the skin, in fixed positions, is difficult. For this reason, in this paper two technologies are shown for the non-contact measurement of two physiological parameters, heart rate and respiratory rate, based on the acquisition and processing of video signals and radar signals. The techniques presented are based on the use of commercial devices. The use of these technologies simplifies the acquisition of vital parameters compared to traditional technologies. The reliability of the measured values was evaluated by comparing the values obtained with a pulse oximeter and an app on a smartphone.
引用
收藏
页码:22 / 26
页数:5
相关论文
共 50 条
  • [11] MEASUREMENT OF PHYSIOLOGICAL PARAMETERS WITH AID OF A COMPUTER
    KALINOVS.AP
    ENVIRONMENTAL SPACE SCIENCES-USSR, 1969, 3 (02): : 148 - &
  • [12] Network approach for physiological parameters measurement
    Rahman, F
    Kumar, A
    Nagendra, G
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 901 - 905
  • [13] Contactless measurement
    不详
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2012, 108 (08) : 404 - 405
  • [14] Contactless area measurement (contactless planimeter)
    Ricny, Vaclav
    Stancik, Petr
    RADIOENGINEERING, 2008, 17 (02) : 115 - 118
  • [15] CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
    Kuznetsov, V. I.
    Tarakanov, S. A.
    Ryzhakov, N. I.
    BYULLETEN SIBIRSKOY MEDITSINY, 2013, 12 (03): : 117 - 120
  • [16] CONTACTLESS MEASUREMENT OF POSITION-TIME-PARAMETERS DURING LOCOMOTOR BEHAVIOR
    MULLER, R
    RUDIGER, W
    ZEITSCHRIFT FUR VERSUCHSTIERKUNDE, 1987, 29 (1-2): : 1 - 7
  • [17] CONTACTLESS RESISTANCE MEASUREMENT
    GUNDERSO.DE
    ISA JOURNAL, 1965, 12 (06): : 84 - &
  • [18] CONTACTLESS MEASUREMENT OF VIBRATIONS
    ZHAROV, EA
    SMYSLOV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (04): : 844 - &
  • [19] Contactless angle measurement
    Rev Sci Instrum, 4 (2175):
  • [20] Privacy-Protected Contactless Sleep Parameters Measurement Using a Defocused Camera
    Zhu, Yingen
    Hong, Hong
    Wang, Wenjin
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (08) : 4660 - 4673