Lung aerosol deposition in suckling infants

被引:18
作者
Amirav, Israel [1 ,2 ]
Luder, Anthony [1 ,2 ]
Chleechel, Aidah [1 ,2 ]
Newhouse, Michael T. [3 ]
Gorenberg, Miguel [4 ]
机构
[1] Bar Ilan Univ, Ziv Med Ctr, IL-13100 Safed, Israel
[2] Bar Ilan Univ, Fac Med, IL-13100 Safed, Israel
[3] McMaster Univ, St Josephs Hosp, Firestone Inst Resp Hlth, Hamilton, ON L8S 4L8, Canada
[4] Ziv Med Ctr, Dept Nucl Med, Safed, Israel
关键词
METERED-DOSE INHALER; CHILDREN; METAANALYSIS; RESISTANCE; NEBULIZER; THERAPY; MASK;
D O I
10.1136/archdischild-2011-301236
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Introduction Aerosol therapy in infants may be greatly compromised by face mask rejection due to squirming and crying. Lung aerosol deposition in crying infants may thereby be greatly reduced. Since 'suckling' on a pacifier calms infants, they should more readily accept a face mask that incorporates a pacifier. However, since infants must breathe nasally while suckling, lung aerosol deposition may be reduced due to impaction in the nose. The aim of the present pilot study was to compare lung aerosol deposition while suckling on a pacifier incorporated into a mask with that obtained while inhaling from a conventional mask. Methods Twelvte infants < 12 months old and who regularly used pacifiers participated as their own controls. Lung aerosol deposition was measured scintigraphically (technetium-(99m)DTPA-labelled normal saline aerosol, MMAD (Mass Median Aerodynamic Diameter) 3 um and GSD (Geometric Standard Deviation) of 2) via jet nebuliser using a conventional mask versus 'suckling' on their pacifier incorporated into a unique mask. Results Mean lung deposition (+/- SD) while suckling using a mask with attached pacifier (1.6 +/- 0.5% in the right lung) was similar to that with a conventional mask (1.7 +/- 0.9%, p=0.81). Conclusions Lung aerosol deposition during nasal breathing while suckling on a pacifier-equipped mask is similar to that in infants breathing quietly using a conventional mask, and results comparable with previous data in infants and in nasal breathing models of an infant's upper respiratory tract. Using a pacifier during aerosol treatment in infants may be as efficient as conventional treatment without a pacifier.
引用
收藏
页码:497 / 501
页数:5
相关论文
共 19 条
[1]   Nebuliser hood compared to mask in wheezy infants: aerosol therapy without tears! [J].
Amirav, I ;
Balanov, I ;
Gorenberg, M ;
Groshar, D ;
Luder, AS .
ARCHIVES OF DISEASE IN CHILDHOOD, 2003, 88 (08) :719-723
[2]   Review of optimal characteristics of face-masks for valved-holding chambers (VHCs) [J].
Amirav, Israel ;
Newhouse, Michael T. .
PEDIATRIC PULMONOLOGY, 2008, 43 (03) :268-274
[3]  
[Anonymous], COCHRANE DATABASE SY
[4]  
ATKINS HL, 1992, J NUCL MED, V33, P1717
[5]  
BECQUEMIN MH, 1991, EUR RESPIR J, V4, P694
[6]   Are infants really obligatory nasal breathers? [J].
Bergeson, PS ;
Shaw, JC .
CLINICAL PEDIATRICS, 2001, 40 (10) :567-569
[7]   THE INFLUENCE OF AGE ON AEROSOL DEPOSITION IN CHILDREN WITH CYSTIC-FIBROSIS [J].
CHUA, HL ;
COLLIS, GG ;
NEWBURY, AM ;
CHAN, K ;
BOWER, GD ;
SLY, PD ;
LESOUEF, PN .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (12) :2185-2191
[8]  
COCKCROFT DW, 1979, AM REV RESPIR DIS, V119, P921
[9]  
Eggli DF, 1991, CLIN PRACTICE NUCL M, P450
[10]  
Everard ML, 2000, ARCH DIS CHILD, V82, P428