Hollow silica microspheres as the stationary phase for thin layer chromatographic separation of a model mixture

被引:2
作者
Qin, Lulu [1 ]
Wang, Haixia [1 ]
Liu, Shiquan [1 ]
机构
[1] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Shandong, Peoples R China
基金
美国国家科学基金会;
关键词
Thin layer chromatography; Hollow silica microspheres; Organic mixture; Nanopores; Shell thickness; TLC;
D O I
10.1016/j.arabjc.2014.02.018
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Hollow silica microspheres (HSMs) with different structures have been synthesized using sacrificed hard template route combined with multiple sol-gel silica shell coating steps. The synthesized HSMs were characterized by SEM and N-2 sorption measurements and employed as the stationary phase in thin layer chromatography. Thin layers of HSMs were coated on glass slides and used to separate a model mixture of methyl red and dimethyl yellow. The conditions to achieve the best chromatographic separation efficiency of the synthesized HSMs were optimized. The results show that the organic mixture could be well-separated using the mixture of cyclohexane/toluene/ethanol as the mobile phase. Distilled water was the best mixing agent for the preparation of the thin layer plates. Activation of the plates at 105 degrees C for 1 h improved the separation efficiency. Under the optimized conditions, the effect of the microstructures of HSMs on the separation efficiency was analyzed. It is shown that the separation efficiency mainly depends on the thickness of the silica shells and the pore size gradient of the nanopores inside the shells. A comparison test shows that HSMs as a stationary phase are advantageous over commercial silica gel in an easy preparation of homogeneous TLC thin plates. (C) 2014 King Saud University. Production and hosting by Elsevier B.V.
引用
收藏
页码:S3515 / S3522
页数:8
相关论文
共 21 条
[1]   Development of efficient SPE-TLC method and evaluation of biological interactions of contraceptives with progesterone receptors [J].
Ali, Imran ;
Hussain, Iqbal ;
Saleem, Kishwar ;
Aboul-Enein, Hassan Y. .
ARABIAN JOURNAL OF CHEMISTRY, 2012, 5 (02) :235-240
[2]  
Anthony J. P., 1990, J POLYM SCI A, V28, P2485
[3]   Spectrophotometric and TLC-densitometric methods for the simultaneous determination of Ezetimibe and Atorvastatin calcium [J].
Baghdady, Yehia Z. ;
Al-Ghobashy, Medhat A. ;
Abdel-Aleem, Abdel-Aziz E. ;
Weshahy, Soheir A. .
JOURNAL OF ADVANCED RESEARCH, 2013, 4 (01) :51-59
[4]  
BRENNER M, 1967, METHOD ENZYMOL, V11, P39
[5]   Development and validation of a stability indicating RP-TLC/densitometric method for determination of Loratadine in bulk and in tablets [J].
Chavhan, Manish L. ;
Shirkhedkar, Atul A. ;
Surana, Sanjay J. .
ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 :S825-S830
[6]  
Fried B., 1999, THIN LAYER CHROMATOG
[7]   Stability indicating method for the determination of paracetamol in its pharmaceutical preparations by TLC densitometric method [J].
Mostafa, Nadia M. .
JOURNAL OF SAUDI CHEMICAL SOCIETY, 2010, 14 (04) :341-344
[8]   Waste glass as absorbent for thin layer chromatography (TLC) [J].
Pant, Deepak .
WASTE MANAGEMENT, 2009, 29 (07) :2040-2041
[9]   Direct ToF-SIMS analysis of organic halides and amines on TLC plates [J].
Parent, Alexander A. ;
Anderson, Thomas M. ;
Michaelis, David J. ;
Jiang, Guilin ;
Savage, Paul B. ;
Linford, Matthew R. .
APPLIED SURFACE SCIENCE, 2006, 252 (19) :6746-6749
[10]   The reaction between phosphatidylethanolamines and HOCl investigated by TLC:: Fading of the dye primuline is induced by dichloramines [J].
Richter, Grit ;
Schober, Celestina ;
Suess, Rosmarie ;
Fuchs, Beate ;
Mueller, Matthias ;
Schiller, Juergen .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (02) :233-237