Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation

被引:135
作者
Lee, C. K. [1 ]
机构
[1] City Univ Hong Kong, Kowloon, Hong Kong, Peoples R China
关键词
Ground-source heat pump; Ground heat exchanger; Borehole; Thermal response test; SYSTEM;
D O I
10.1016/j.apenergy.2011.05.023
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A modified three-dimensional finite difference model for the borehole ground heat exchangers of a ground-source heat pump (GSHP) system was developed which accounted for multiple ground layers with different thermal properties in the borefield at no groundwater flow. The present model was used to investigate the impact of ignoring ground layers in the thermal response test (TRT) analysis and the subsequent system simulation. It was found that the adoption of an effective ground thermal conductivity and an effective ground volumetric heat capacity for a multi-layer ground determined from a TRT analysis led to very little error in the simulated long term system performance under various ground compositions investigated. The maximum difference occurred for a 3 x 3 borefield in a dual-layer ground which measured 0.5 degrees C or 3.9% in the rise of the borefield fluid leaving temperature with a cooling-dominated loading profile for 10 years. With the same borefield and ground composition, a dynamic simulation of the complete GSHP system was performed using the TRNSYS simulation software. It was found that the overall system performance based on the present and the old models differed very little. It was concluded that the assumption of a homogeneous ground in a TRT analysis and subsequent system simulation was appropriate and impact of ignoring ground layers was small. A single-ground-layer model, including the analytical models, was sufficient even for a multi-layer ground. This could reduce the computation time significantly, especially when simulating a large borefield. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4405 / 4410
页数:6
相关论文
共 27 条
[1]  
*ASHRAE, 2003, ASHRAE HDB HVAC APPL, pCH32
[2]  
Austin W., 2000, ASHRAE T, V106, P365
[3]   Applications of ground source heat pump systems in different temperature zones in China [J].
Bi, Y. ;
Wang, X. ;
Liu, Y. ;
Tian, R. ;
Chen, L. ;
Wu, C. .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2009, 30 (02) :63-72
[4]  
Carslaw H.S., 1986, Conduction of Heat In Solids, V2nde
[5]   Generation of a typical meteorological year for Hong Kong [J].
Chan, ALS ;
Chow, TT ;
Fong, SKF ;
Lin, JZ .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) :87-96
[6]   Modeling a ground-coupled heat pump system by a support vector machine [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Sengur, Abdulkadir ;
Esen, Mehmet .
RENEWABLE ENERGY, 2008, 33 (08) :1814-1823
[7]   Modelling a ground-coupled heat pump system using adaptive neuro-fuzzy inference systems [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Sengur, Abdulkadir ;
Esen, Mehmet .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (01) :65-74
[8]   Numerical and experimental analysis of a horizontal ground-coupled heat pump system [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet .
BUILDING AND ENVIRONMENT, 2007, 42 (03) :1126-1134
[9]  
Eskilson P., 1987, Ph.D. Thesis, P264
[10]   Comparative study of different solar cooling systems for buildings in subtropical city [J].
Fong, K. F. ;
Chow, T. T. ;
Lee, C. K. ;
Lin, Z. ;
Chan, L. S. .
SOLAR ENERGY, 2010, 84 (02) :227-244