Ex Vivo Stability Loss of Irradiated and Melted Ultra-High Molecular Weight Polyethylene

被引:69
作者
Muratoglu, Orhun K. [1 ]
Wannomae, Keith K. [1 ]
Rowell, Shannon L. [1 ]
Micheli, Brad R. [1 ]
Malchau, Henrik [1 ]
机构
[1] Massachusetts Gen Hosp, Harris Orthopaed Lab, Boston, MA 02114 USA
关键词
CROSS-LINKED POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; IN-VIVO; ACETABULAR COMPONENTS; CLINICAL-PERFORMANCE; GAMMA-STERILIZATION; FREE-RADICALS; UHMWPE; OXIDATION; WEAR;
D O I
10.2106/JBJS.I.01017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Radiation crosslinking reduces wear of ultra-high molecular weight polyethylene (UHMWPE), and subsequent annealing or melting increases oxidative stability Little is known about the oxidative stability of polyethylene total joint components after in vivo service and subsequent shelf storage in air Methods We analyzed thirty-four surgically retrieved, radiation crosslinked acetabular liners to determine their oxidative stability after in vivo service (range, 0 5 to 84 0 months) Oxidation was determined at the time of explantation After shelf storage in air (range, 7 0 to 72 0 months), oxidation, crosslink density, and thermal properties were determined Oxidation of one control liner that was shelf-aged in air (for eighty four months) was also determined Results At the time of explantation, all components showed minimal oxidation, however, oxidation levels increased during shelf storage, with a concomitant decrease in crosslink density and increase in crystallinity Increasing oxidation, increasing crystallinity, and decreasing crosslink density correlated with the duration of ex vivo storage The shelf-aged control liner showed no detectable oxidation Conclusions The oxidation and loss of crosslink density of the irradiated and melted UHMWPE was surprising Two potential mechanisms that might alter the oxidative stability of UHMWPE in vivo are cyclic loading and absorption of lipids Both of these mechanisms can generate new free radicals in UHMWPE and can initiate and propagate its oxidation Clinical Relevance It is not known if the ex vivo instability reported here will occur in vivo in the long term and, therefore, further investigation of surgical explants is warranted
引用
收藏
页码:2809 / 2816
页数:8
相关论文
共 22 条
  • [1] BISTOLFI A, 2005, UHMWPE T 51 ANN M OR, P240
  • [2] Reduction of osteolysis with use of Marathon cross-linked polyethylene - A concise follow-up, at a minimum of five years, of a previous report
    Bitsch, Rudi G.
    Loidolt, Travis
    Heisel, Christian
    Ball, Scott
    Schmalzried, Thomas P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) : 1487 - 1491
  • [3] Impact of gamma sterilization on clinical performance of polyethylene in the knee
    Collier, JP
    Sperling, DK
    Currier, JH
    Sutula, LC
    Saum, KA
    Mayor, MB
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (04) : 377 - 389
  • [4] Analysis of products diffused into UHMWPE prosthetic components in vivo
    Costa, L
    Bracco, P
    del Prever, EB
    Luda, MP
    Trossarelli, L
    [J]. BIOMATERIALS, 2001, 22 (04) : 307 - 315
  • [5] Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups
    Currier, Barbara H.
    Currier, John H.
    Mayor, Michael B.
    Lyford, Kimberly A.
    Collier, John P.
    Van Citters, Douglas W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) : 2023 - 2029
  • [6] 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis
    Digas, Georgios
    Karrholm, Johan
    Thanner, Jonas
    Herberts, Peter
    [J]. ACTA ORTHOPAEDICA, 2007, 78 (06) : 746 - 754
  • [7] CHOLESTEROL BIOSYNTHESIS - STUDIES RELATED TO THE METABOLIC ROLE OF SQUALENE
    EIDINOFF, ML
    KNOLL, JE
    MARANO, BJ
    KVAMME, E
    ROSENFELD, RS
    HELLMAN, L
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1958, 37 (05) : 655 - 659
  • [8] A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners
    Engh, C. Anderson, Jr.
    Stepniewski, Adam S.
    Ginn, Stuart D.
    Beykirch, Sarah E.
    Sychterz-Terefenko, Christi J.
    Hopper, Robert H., Jr.
    Engh, Charles A.
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (06) : 17 - 25
  • [9] IMAEDA K, 1983, BUNSEKI KAGAKU, V32, P406
  • [10] COMBINED CHEMICAL AND MECHANICAL EFFECTS ON FREE-RADICALS IN UHMWPE JOINTS DURING IMPLANTATION
    JAHAN, MS
    WANG, C
    SCHWARTZ, G
    DAVIDSON, JA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (08): : 1005 - 1017