Spot-scanning beam delivery with laterally-and longitudinally-mixed spot size pencil beams in heavy ion radiotherapy

被引:8
作者
Yan, Yuan-Lin [1 ,2 ,3 ,4 ]
Liu, Xin-Guo [1 ,2 ,3 ]
Dai, Zhong-Ying [1 ,2 ,3 ]
Ma, Yuan-Yuan [1 ,2 ,3 ,4 ]
He, Peng-Bo [1 ,2 ,3 ]
Shen, Guo-Sheng [1 ,2 ,3 ,4 ]
Ji, Teng-Fei [1 ,2 ,3 ,4 ]
Zhang, Hui [1 ,2 ,3 ,4 ]
Li, Qiang [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Key Lab Heavy Ion Radiat Biol & Med, Lanzhou 730000, Gansu, Peoples R China
[3] Key Lab Basic Res Heavy Ion Radiat Applicat Med, Lanzhou 730000, Gansu, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
heavy ion radiotherapy; spot-scanning; beam spot size; mini spread-out Bragg peak (mini-SOBP); mini ridge filter (mini-RF); PROTON RADIOTHERAPY; IRRADIATION SYSTEM; PARTICLE THERAPY; RIDGE FILTER; OPTIMIZATION; DESIGN; EXTRACTION;
D O I
10.1088/1674-1137/41/9/098201
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The three-dimensional (3D) spot-scanning method is one of the most commonly used irradiation methods in charged particle beam radiotherapy. Generally, spot-scanning beam delivery utilizes the same size pencil beam to irradiate the tumor targets. Here we propose a spot-scanning beam delivery method with laterally- and longitudinally mixed size pencil beams for heavy ion radiotherapy. This uses pencil beams with a bigger spot size in the lateral direction and wider mini spread-out Bragg peak (mini-SOBP) to irradiate the inner part of a target volume, and pencil beams with a smaller spot size in the lateral direction and narrower mini-SOBP to irradiate the peripheral part of the target volume. Instead of being controlled by the accelerator, the lateral size of the pencil beam was adjusted by inserting Ta scatterers in the beam delivery line. The longitudinal size of the pencil beam (i.e. the width of the mini-SOBP) was adjusted by tilting mini ridge filters along the beam direction. The new spot-scanning beam delivery using carbon ions was investigated theoretically and compared with traditional spot-scanning beam delivery. Our results show that the new spot-scanning beam delivery has smaller lateral penumbra, steeper distal dose fall-off and the dose homogeneity (1-standard deviation/mean) in the target volume is better than 95%.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] Bassler N., 2014, J PHYS C SERIES
  • [2] Bassler N., 2016, SHIELD HIT12A USERS
  • [3] Quantification of interplay effects of scanned particle beams and moving targets
    Bert, Christoph
    Groezinger, Sven O.
    Rietzel, Eike
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) : 2253 - 2265
  • [4] Active spot-scanning test with heavy ions at HIRFL-CSR
    Dai Zhong-Ying
    Li Qiang
    Liu Xin-Guo
    Jin Xiao-Dong
    Huang Qi-Yan
    Xiao Guo-Qing
    [J]. CHINESE PHYSICS C, 2012, 36 (08) : 784 - 791
  • [5] Reduction of the number of stacking layers in proton uniform scanning
    Fujitaka, Shinichiro
    Takayanagi, Taisuke
    Fujimoto, Rintaro
    Fujii, Yusuke
    Nishiuchi, Hideaki
    Ebina, Futaro
    Okazaki, Takashi
    Hiramoto, Kazuo
    Sakae, Takeji
    Terunuma, Toshiyuki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3101 - 3111
  • [6] Characteristics of fast beam switching for spot scanning
    Furukawa, T
    Noda, K
    Urakabe, E
    Muramatsu, M
    Kanazawa, M
    Maeda, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 503 (03) : 485 - 495
  • [7] Fast beam cut-off method in RF-knockout extraction for spot-scanning
    Furukawa, T
    Noda, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3) : 59 - 67
  • [8] MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY
    HABERER, T
    BECHER, W
    SCHARDT, D
    KRAFT, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) : 296 - 305
  • [9] Recent improvements in the SHIELD-HIT code
    Hansen, David C.
    Luhr, Armin
    Herrmann, Rochus
    Sobolevsky, Nikolai
    Bassler, Niels
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2012, 88 (1-2) : 195 - 199
  • [10] Spreading of a heavy ion beam with the dual-ring double scattering method
    Himukai, T.
    Furukawa, T.
    Takeshita, E.
    Inaniwa, T.
    Mizushima, K.
    Katagiri, K.
    Takada, Y.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24) : 2891 - 2894