High-Throughput Method for the Quantification of Lacosamide in Serum Using Ultrafast SPE-MS/MS

被引:9
|
作者
Korman, Eric [1 ]
Langman, Loralie J. [1 ,2 ]
Jannetto, Paul J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, Toxicol & Drug Monitoring Lab, Rochester, MN USA
[2] Mayo Clin, Dept Lab Med & Pathol, Div Clin Biochem & Immunol, Rochester, MN USA
关键词
LC-MS/MS; SPE-MS/MS; lacosamide; antiepileptic; TANDEM MASS-SPECTROMETRY; ANTIEPILEPTIC DRUGS; EPILEPSY; PLASMA;
D O I
10.1097/FTD.0000000000000115
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Lacosamide is an anticonvulsant drug approved for adjunctive therapy of partial-onset seizures in adults. Monitoring serum lacosamide concentrations may be useful in assessing compliance and optimizing therapy. The clinical need for faster turn-aroundtimes and increased testing volumes has led to the desire to develop faster methods of analysis for higher throughput of samples. Methods: Fifty microliters of calibration standards, quality controls, and patient samples were precipitated with methanol containing deuterated internal standard. The supernatant was then diluted with aqueous mobile phase and injected on an ultrafast solid-phase extraction-mass spectrometry with a cycle time of <10 seconds per sample. Results: The analytic linear range for the assay was 0.5-50.0 mcg/mL with a limit of detection of 0.05 mcg/mL. The assay showed interassay and intraassay precision coefficient of variations <7%, with no significant carryover after a sample twice the upper limit of quantitation, and no interference from the top 24 prescribed drugs, other anticonvulsants, or common drugs of abuse. Analytical accuracy was determined by comparing 26 results (19 patients, 7 standards and quality control) with a reference laboratory using liquid chromatography-mass spectrometry in addition to 11 proficiency samples from the LGC Standards Proficiency Testing survey. The results were compared using a standard linear regression with the equation of the line being y = 1.093x - 0.166, with an r(2) = 0.99, and a y intercept 95% confidence interval that included zero. Conclusions: Herein, the authors present a method for the quantification of lacosamide in serum with ultrafast solid-phase extraction-mass spectrometry that uses 50 mu L of sample, is linear from 0.5 to 50 mcg/mL, has interassay and intraassay coefficient of variations of <7%, and has much faster sample cycle times with similar analytic results compared with traditional liquid chromatography-mass spectrometry.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [21] Fast and straightforward simultaneous quantification of multiple apolipoproteins in human serum on a high-throughput LC-MS/MS platform
    Kim, Hyojin
    Yang, Won Suk
    An, Dongheui
    Lee, Sang-Guk
    Baek, Je-Hyun
    PROTEOMICS CLINICAL APPLICATIONS, 2022,
  • [22] Ultrafast Quantitative Analysis of Small Molecules in Serum and Urine Using an Online SPE/MS/MS System
    Youssef, M.
    Miller, V
    LaMarr, W.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 698 - 698
  • [23] High-throughput quantification of 8 antihypertensive drugs and active metabolites in human plasma using UPLC MS/MS
    van der Nagel, Bart C. H.
    Versmissen, Jorie
    Bahmany, Soma
    van Gelder, Teun
    Koch, Birgit C. P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 367 - 373
  • [24] Quantification of the anti-influenza drug zanamivir in plasma using high-throughput HILIC-MS/MS
    Lindegardh, Niklas
    Hanpithakpong, Warunee
    Kamanikom, Benjamas
    Farrar, Jeremy
    Tran Tinh Hien
    Singhasivanon, Pratap
    White, Nicholas J.
    Day, Nicholas P. J.
    BIOANALYSIS, 2011, 3 (02) : 157 - 165
  • [25] A high-throughput LC-MS/MS method for the quantification of four immunosu- ppressants drugs in whole blood
    Gong, Zi-Shan
    Wu, Zhong-Hao
    Xu, Shu-Xin
    Han, Wen-Nian
    Jiang, Xiao-Mei
    Liu, Hai -Pei
    Yan-Li
    Wei-Hu
    Yan-Wang
    CLINICA CHIMICA ACTA, 2019, 498 : 21 - 26
  • [26] MALDI-MS/MS-BASED HIGH-THROUGHPUT BIOMARKER PROTEIN QUANTIFICATION WITH A NEW INTERNAL STANDARD METHOD
    Yoneyama, Toshihiro
    Ohtsuki, Sumio
    Uchida, Yasuo
    Tachikawa, Masanori
    Terasaki, Tetsuya
    DRUG METABOLISM REVIEWS, 2015, 47 : 159 - 159
  • [27] High-Throughput LC-MS/MS Method for Direct Quantification of Glucuronidated, Sulfated, and Free Enterolactone in Human Plasma
    Norskov, Natalja P.
    Kyro, Cecilie
    Olsen, Anja
    Tjonneland, Anne
    Knudsen, Knud Erik Bach
    JOURNAL OF PROTEOME RESEARCH, 2016, 15 (03) : 1051 - 1058
  • [28] High-throughput quantification of drugs and their metabolites in biosamples by LC-MS/MS and CE-MS/MS: Possibilities and limitations
    Hopfgartner, G
    Husser, C
    Zell, M
    THERAPEUTIC DRUG MONITORING, 2002, 24 (01) : 134 - 143
  • [29] High-throughput DART-MS/MS for quantification of carboxymethyl lysine and carboxyethyl lysine in beef
    Luo, Bangping
    Zhang, Liangyu
    Zhang, Cong
    Chen, Wuzhi
    Mo, Jingjing
    Li, Weili
    Wu, Tao
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 136
  • [30] Metaxalone estimation in biological matrix using high-throughput LC-MS/MS bioanalytical method
    Goswami, Dipanjan
    Saha, Arabinda
    Gurule, Sanjay
    Khuroo, Arshad
    Monif, Tausif
    Vats, Poonam
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 132 - 136