High-Throughput Method for the Quantification of Lacosamide in Serum Using Ultrafast SPE-MS/MS

被引:9
|
作者
Korman, Eric [1 ]
Langman, Loralie J. [1 ,2 ]
Jannetto, Paul J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, Toxicol & Drug Monitoring Lab, Rochester, MN USA
[2] Mayo Clin, Dept Lab Med & Pathol, Div Clin Biochem & Immunol, Rochester, MN USA
关键词
LC-MS/MS; SPE-MS/MS; lacosamide; antiepileptic; TANDEM MASS-SPECTROMETRY; ANTIEPILEPTIC DRUGS; EPILEPSY; PLASMA;
D O I
10.1097/FTD.0000000000000115
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Lacosamide is an anticonvulsant drug approved for adjunctive therapy of partial-onset seizures in adults. Monitoring serum lacosamide concentrations may be useful in assessing compliance and optimizing therapy. The clinical need for faster turn-aroundtimes and increased testing volumes has led to the desire to develop faster methods of analysis for higher throughput of samples. Methods: Fifty microliters of calibration standards, quality controls, and patient samples were precipitated with methanol containing deuterated internal standard. The supernatant was then diluted with aqueous mobile phase and injected on an ultrafast solid-phase extraction-mass spectrometry with a cycle time of <10 seconds per sample. Results: The analytic linear range for the assay was 0.5-50.0 mcg/mL with a limit of detection of 0.05 mcg/mL. The assay showed interassay and intraassay precision coefficient of variations <7%, with no significant carryover after a sample twice the upper limit of quantitation, and no interference from the top 24 prescribed drugs, other anticonvulsants, or common drugs of abuse. Analytical accuracy was determined by comparing 26 results (19 patients, 7 standards and quality control) with a reference laboratory using liquid chromatography-mass spectrometry in addition to 11 proficiency samples from the LGC Standards Proficiency Testing survey. The results were compared using a standard linear regression with the equation of the line being y = 1.093x - 0.166, with an r(2) = 0.99, and a y intercept 95% confidence interval that included zero. Conclusions: Herein, the authors present a method for the quantification of lacosamide in serum with ultrafast solid-phase extraction-mass spectrometry that uses 50 mu L of sample, is linear from 0.5 to 50 mcg/mL, has interassay and intraassay coefficient of variations of <7%, and has much faster sample cycle times with similar analytic results compared with traditional liquid chromatography-mass spectrometry.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [1] High-Throughput Validated Method for the Quantification of Lacosamide in Serum Using Ultra Fast SPE-MS/MS
    Korman, E.
    Bjergum, M.
    Danso, D.
    Erbsen, J.
    Enger, R.
    Langman, L.
    Jannetto, P.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 675 - 675
  • [2] High-Throughput Validated Method for the Quantitation of Busulfan in Plasma Using Ultrafast SPE-MS/MS
    Danso, Darlington
    Jannetto, Paul J.
    Enger, Robert
    Langman, Loralie J.
    THERAPEUTIC DRUG MONITORING, 2015, 37 (03) : 319 - 324
  • [3] High-Throughput Validated Method for the Quantitaion of Busulfan in Plasma Using Ultra-fast SPE-MS/MS
    Danso, Darlington
    Bjergum, Matthew
    Enger, Robert
    Jannetto, Paul
    Langman, Loralie
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 678 - 679
  • [4] Ultrafast Online SPE-MS/MS Method for Quantification of 3 Tyrosine Kinase Inhibitors in Human Plasma
    Vrobel, Ivo
    Janeckova, Hana
    Faber, Edgar
    Bouchalova, Katerina
    Micova, Katerina
    Friedecky, David
    Adam, Tomas
    THERAPEUTIC DRUG MONITORING, 2016, 38 (04) : 516 - 524
  • [5] High-throughput Quantification of Cotinine in Urine, Serum and Meconium by UPLC-MS-MS With Automated SPE
    Langlois, Eric
    Bisson, David
    Lefebvre, Michel
    Simard, Yves
    THERAPEUTIC DRUG MONITORING, 2009, 31 (05) : 628 - 628
  • [6] ULTRAFAST PLASMA PROTEIN BINDING ANALYSIS USING A HIGH-THROUGHPUT SPE/TOF-MS SYSTEM
    Schlicht, Kari E.
    Miller, Vaughn P.
    LaMarr, William A.
    Ozbal, Can
    DRUG METABOLISM REVIEWS, 2014, 45 : 158 - 158
  • [7] High-Throughput and Selective Forensic Drug Screening in Urine Using a SPE/MS/MS System
    Romm, M.
    Schlicht, K.
    Parikh, N.
    Youssef, M.
    Miller, V
    LaMarr, W.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 682 - 682
  • [8] Stability and Validation of a High-Throughput LC-MS/MS Method for the Quantification of Cefepime, Meropenem, and Piperacillin and Tazobactam in Serum
    Bjergum, Matthew W.
    Barreto, Erin F.
    Scheetz, Marc H.
    Rule, Andrew D.
    Jannetto, Paul J.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (05): : 1202 - 1212
  • [9] ULTRA-FAST ONLINE SPE-MS/MS METHOD FOR QUANTIFICATION OF FOUR TYROSINE KINASE INHIBITORS IN HUMAN PLASMA
    Vrobel, Ivo
    Micova, Katerina
    Friedecky, David
    Faber, Edgar
    Adam, Tomas
    CECE 2014: 11TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2014, : 464 - 465
  • [10] Rapid, high-throughput method for the quantification of thyroid hormones in rat blood serum using isotope-dilution LC-MS/MS
    Powley, Charles R.
    Dong, Jinlan
    Hannas, Bethany R.
    Shen, Zhihua Amanda
    BIOANALYSIS, 2020, 12 (23) : 1689 - 1698