Utilizing the diffusion-to-noise ratio to optimize magnetic resonance diffusion tensor acquisition strategies for improving measurements of diffusion anisotropy

被引:34
作者
Armitage, PA
Bastin, ME
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[2] Univ Edinburgh, Western Gen Hosp, Dept Med Phys & Med Engn, Edinburgh, Midlothian, Scotland
关键词
magnetic resonance imaging; diffusion tensor imaging; diffusion anisotropy; diffusion-to-noise ratio; optimized acquisition;
D O I
10.1002/mrm.1140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is well known that quantitative anisotropy measurements derived from the diffusion tenser are extremely sensitive to noise contamination, The level of noise in the diffusion tenser imaging (DTI) experiment is usually measured from some estimate of the signal-to-noise ratio (SNR) in the component diffusion-weighted (DW) images. This measure is, however, highly dependent on experimental parameters, such as the diffusion attenuation b-value and the diffusion coefficient of the subject. Conversely the diffusion-to-noise ratio (DNR), defined as the SNR of the calculated diffusion tenser trace map, provides a reliable estimate of noise contamination, which is largely independent of such parameters. In this work it is demonstrated how reliable anisotropy measurements can be obtained using an image acquisition strategy that optimizes the DNR of the DTI experiment, This acquisition scheme is shown to provide noise-independent measurements of typical diffusion anisotropy values found in the human brain. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:1056 / 1065
页数:10
相关论文
共 28 条
[1]   Diffusion anisotropy measurements in ischaemic stroke of the human brain [J].
Armitage, P. A. ;
Bastin, M. E. ;
Marshall, I. ;
Wardlaw, J. M. ;
Cannon, J. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1998, 6 (01) :28-36
[2]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[3]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[4]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[5]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[6]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[7]   A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging [J].
Bastin, ME ;
Armitage, PA ;
Marshall, I .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :773-785
[8]   MRI white matter diffusion anisotropy and PET metabolic rate in schizophrenia [J].
Buchsbaum, MS ;
Tang, CY ;
Peled, S ;
Gudbjartsson, H ;
Lu, DF ;
Hazlett, EA ;
Downhill, J ;
Haznedar, M ;
Fallon, JH ;
Atlas, SW .
NEUROREPORT, 1998, 9 (03) :425-430
[9]   NAVIGATED DIFFUSION IMAGING OF NORMAL AND ISCHEMIC HUMAN BRAIN [J].
DECRESPIGNY, AJ ;
MARKS, MP ;
ENZMANN, DR ;
MOSELEY, ME .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :720-728
[10]   MAGNETIC-RESONANCE-IMAGING OF THERMAL-CONVECTION [J].
GIBBS, SJ ;
CARPENTER, TA ;
HALL, LD .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (02) :209-214