Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods

被引:28
|
作者
Galstyan, Gennady [1 ]
Bychinin, Mychaylo [1 ]
Alexanyan, Mikael [1 ]
Gorodetsky, Vladimir [1 ]
机构
[1] Natl Hematol Res Ctr, Dept Intens Care, Moscow, Russia
关键词
Cardiac output; Blood volumes; Transpulmonary thermodilution; Ultrasound dilution; HEMODIALYSIS; VALIDATION; SURGERY; BIAS;
D O I
10.1007/s00134-010-2003-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To compare cardiac output (CO) and blood volumes measured by COstatus(A (R)) (Transonic Systems Inc., NY, USA) versus PiCCO (Philips IntelliVue MP40 with PiCCO-technology module M3012A#10, Netherlands) in adult ICU patients. This was a prospective single-center study. Each of the 30 patients studied received a 5-Fr Pulsiocath femoral arterial and a standard central venous catheter. Twenty ml of iced 5% dextrose solution was injected for PiCCO measurements. For COstatus measurements, an extracorporeal arteriovenous loop, with two sensors placed on it, was connected between the Pulsiocath femoral arterial and central venous catheters. Blood was circulated through this loop at 12 ml/min for 5-8 min using a pump. Twenty ml of warm saline was injected into the venous side for measurements. For each method, three injections were averaged for comparison. A good agreement for measured CO (range 3.65-16.3 l/min) with a percentage error of 20% was observed, with r = 0.95, bias = -0.037 l/min. PiCCO's global end-diastolic volume (GEDV) was 2.5 times larger than the analogous COstatus's total end-diastolic volume (TEDV) [TEDV = 0.28 x GEDV + 176 ml]. PiCCO's intrathoracic blood volume (ITBV) was larger than the analogous COstatus's central blood volume (CBV) [CBV = 0.73 x (ITBV) +78 ml]. CO measured by COstatus was found to be equivalent and hence interchangeable with PiCCO in this study population. COstatus blood volumes were found to be within the expected physiological range whilst PiCCO blood volumes were significantly higher, which was also observed in other studies. Future studies using 3D echo/MRI are required to validate these blood volumes.
引用
收藏
页码:2140 / 2144
页数:5
相关论文
共 50 条
  • [1] Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods
    Gennady Galstyan
    Mychaylo Bychinin
    Mikael Alexanyan
    Vladimir Gorodetsky
    Intensive Care Medicine, 2010, 36 : 2140 - 2144
  • [2] COMPARISON OF CARDIAC OUTPUT (CO) MEASURED BY ULTRASOUND DILUTION (UD) AND TRANSPULMONARY THERMODILUTION (TPD) METHODS IN A PEDIATRIC ANIMAL MODEL.
    Darling, E.
    Searles, B.
    Thuramalla, N.
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A56 - A56
  • [3] COMPARISON OF CARDIAC OUTPUT (CO) MEASURED BY NEW ULTRASOUND DILUTION METHOD (UD) VERSUS TRANSPULMONARY THERMODILUTION (TT) METHOD.
    Galstyan, Gennady
    Alexanyan, Michail
    Gorodetsky, Vladimir
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A57 - A57
  • [4] Cardiac output measured by lithium dilution and transpulmonary thermodilution in adult intensive care patients
    Smith, J
    Kirwan, C
    Lei, K
    Beale, R
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A56 - A56
  • [5] Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
    R. A. Linton
    M. M. Jonas
    S. M. Tibby
    I. A. Murdoch
    T. K. O'Brien
    N. W. F. Linton
    D. M. Band
    Intensive Care Medicine, 2000, 26 : 1507 - 1511
  • [6] Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
    Linton, RA
    Jonas, MM
    Tibby, SM
    Murdoch, IA
    O'Brien, TK
    Linton, NWF
    Band, DM
    INTENSIVE CARE MEDICINE, 2000, 26 (10) : 1507 - 1511
  • [7] Pulmonary blood volume measured by contrast enhanced ultrasound: a comparison with transpulmonary thermodilution
    Herold, I. H. F.
    Hamad, M. A. Soliman
    van Assen, H. C.
    Bouwman, R. A.
    Korsten, H. H. M.
    Mischi, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (01) : 53 - 60
  • [8] Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology
    Breukers, RBGE
    Jansen, JRC
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (05) : 658 - 661
  • [9] DISCRAPENCY BETWEEN VOLUME PARAMETERS MEASURED BY NEW ULTRASOUND DILUTION (UD) AND TRANSPULMONARY THERMODILUTION (TT) METHODS.
    Galstyan, Gennady
    Alexanyan, Michail
    Gorodetsky, Vladimir
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A58 - A58
  • [10] Measurement of intrathoracic blood volume by lithium dilution: comparison with thermodilution
    H Roberts
    A Saayman
    L Ala
    G Findlay
    Critical Care, 11 (Suppl 2):