Percutaneous Driveline Fracture After Implantation of the HeartMate II Left Ventricular Assist Device: How Durable is Driveline Repair?

被引:10
作者
Stulak, John M. [1 ]
Schettle, Sarah [1 ]
Haglund, Nicholas [2 ]
Dunlay, Shannon [2 ]
Cowger, Jennifer [3 ]
Shah, Palak [4 ]
Aaronson, Keith D. [5 ]
Pagani, Francis D. [5 ]
Maltais, Simon [1 ]
机构
[1] Mayo Clin, Coll Med, 200 First St SW, Rochester, MN 55905 USA
[2] Vanderbilt Univ, Med Ctr, Vanderbilt Heart, Nashville, TN USA
[3] St Vincent Heart Inst, Indianapolis, IN USA
[4] Inova Heart & Vasc Inst, Falls Church, VA USA
[5] Univ Michigan, Sch Med, Ann Arbor, MI USA
关键词
Driveline; driveline fracture; mechanical circulatory support; FAILURE;
D O I
10.1097/MAT.0000000000000531
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Durability of the percutaneous driveline is critical for the optimal long-term support of patients after left ventricular assist device (LVAD) implantation. There are no data specifically examining the durability of major repair for driveline fracture or its effect on patient outcomes. Between May 2004 and August 2014, 560 patients underwent implantation with the HeartMate II LVAD at our respective institutions. Median age at LVAD implantation was 59 years (range 18-82 years) and 465 patients (83%) were male. The indication for LVAD implantation was bridge to transplant (BTT) in 296 patients (53%). Follow-up was available in all early survivors (n = 519) for a total of 940 patient-years of support (median 1.1 years, max. 10.4 years). Percutaneous driveline fracture was identified in 17 patients (3.2%), eight of whom were implanted as destination therapy. Median time from LVAD implantation to driveline fracture was 1.3 years (range, from 4 months to 3.8 years). Two of these patients underwent device exchange as primary treatment, while 15/17 (88%) underwent repair. Three of these 15 patients required a driveline reintervention, including device exchange (n = 1), rerepair (n = 1), and ungrounded cables (n = 1). Median time of support after driveline repair was 10 months (range from 3 months to 5.4 years). There were no late deaths after driveline repair during the follow-up period with 14/15 patients (93%) active on support and one having undergone transplant. The incidence of percutaneous driveline fracture after HeartMate II LVAD implantation is low (3.9%). The majority of driveline repairs for driveline fracture are durable with reintervention required in a minority of patients. There was no adverse effect of driveline fracture requiring repair on late outcome noted in this series with all patients either active on support or transplanted at last follow-up.
引用
收藏
页码:542 / 545
页数:4
相关论文
共 10 条
  • [1] A CASE OF INTRAOPERATIVE OUTER SHEATHING DAMAGE CAUSING LEAKING OF BLOOD INSIDE THE LEFT VENTRICULAR ASSIST DEVICE DRIVELINE
    Caminero, Margarita V. Perez
    Chaparro, Sandra
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A666 - A666
  • [2] EMERGENT RECONNECTION OF A TRANSECTED LEFT VENTRICULAR ASSIST DEVICE DRIVELINE
    Cubillo, Efrain Israel
    Weis, Ricardo A.
    Ramakrishna, Harish
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (05) : 546 - 551
  • [3] Urgent Exchange of a HeartMate II Left Ventricular Assist Device After Percutaneous Lead Fracture
    Jafar, Mehdi
    Gregoric, Igor D.
    Radovancevic, Rajko
    Cohn, William E.
    McGuire, Nichole
    Frazier, O. H.
    [J]. ASAIO JOURNAL, 2009, 55 (05) : 523 - 524
  • [4] Percutaneous Lead Dysfunction in the HeartMate II Left Ventricular Assist Device
    Kalavrouziotis, Dimitri
    Tong, Michael Z.
    Starling, Randall C.
    Massiello, Alex
    Soltesz, Edward
    Smedira, Nicholas G.
    Fryc, Robert
    Heatley, Gerald
    Farrar, David J.
    Moazami, Nader
    [J]. ANNALS OF THORACIC SURGERY, 2014, 97 (04) : 1373 - 1378
  • [5] Pump Replacement for Left Ventricular Assist Device Failure Can Be Done Safely and Is Associated With Low Mortality
    Moazami, Nader
    Milano, Carmelo A.
    John, Ranjit
    Sun, Benjamin
    Adamson, Robert M.
    Pagani, Francis D.
    Smedira, Nicholas
    Slaughter, Mark S.
    Farrar, David J.
    Frazier, O. Howard
    [J]. ANNALS OF THORACIC SURGERY, 2013, 95 (02) : 500 - 505
  • [6] Outcomes in Advanced Heart Failure Patients With Left Ventricular Assist Devices for Destination Therapy
    Park, Soon J.
    Milano, Carmelo A.
    Tatooles, Antone J.
    Rogers, Joseph G.
    Adamson, Robert M.
    Steidley, D. Eric
    Ewald, Gregory A.
    Sundareswaran, Kartik S.
    Farrar, David J.
    Slaughter, Mark S.
    [J]. CIRCULATION-HEART FAILURE, 2012, 5 (02) : 241 - 248
  • [7] Fracture of the total artificial heart pneumatic driveline after transition to the portable driver
    Shah, Keyur B.
    Volman, Regina A.
    Harton, Suzanne
    Tang, Daniel G.
    Kasirajan, Vigneshwar
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (10) : 1041 - 1043
  • [8] Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device
    Slaughter, Mark S.
    Rogers, Joseph G.
    Milano, Carmelo A.
    Russell, Stuart D.
    Conte, John V.
    Feldman, David
    Sun, Benjamin
    Tatooles, Antone J.
    Delgado, Reynolds M., III
    Long, James W.
    Wozniak, Thomas C.
    Ghumman, Waqas
    Farrar, David J.
    Frazier, O. Howard
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) : 2241 - 2251
  • [9] Repair of left ventricular driveline tear in a SynCardia-total artificial heart patient
    Spiliopoulos, Sotirios
    Tenderich, Magda
    Guersoy, Dilek
    Dogan, Guenes
    Koerfer, Reiner
    Tenderich, Gero
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [10] Low Bearing Wear in Explanted HeartMate II Left Ventricular Assist Devices After Chronic Clinical Support
    Sundareswaran, Kartik S.
    Reichenbach, Steven H.
    Masterson, Karen B.
    Butler, Kenneth C.
    Farrar, David J.
    [J]. ASAIO JOURNAL, 2013, 59 (01) : 41 - 45