Increasing the "region of interest" and "time of interest", both reduce the variability of blood flow measurements using laser speckle contrast imaging

被引:74
作者
Rousseau, Pascal [1 ,2 ,5 ]
Mahe, Guillaume [1 ,5 ]
Haj-Yassin, Firas [1 ,2 ]
Durand, Sylvain [3 ]
Humeau, Anne [4 ]
Leftheriotis, Georges [1 ,5 ]
Abraham, Pierre [1 ,5 ]
机构
[1] Univ Hosp Angers, Lab Vasc Invest, F-49933 Angers 9, France
[2] Univ Hosp Angers, Dept Plast Surg, F-49933 Angers 9, France
[3] Univ Le Mans, Fac Sport Sci, Lab Motricite Interact Performance EA 4334, Le Mans, France
[4] Univ Angers, LISA, F-49000 Angers, France
[5] Fac Med, Biol Neurovasc Integree BNVI, Unite Mixte UMR CNRS 6214, INSERM 771, Angers, France
关键词
REPRODUCIBILITY;
D O I
10.1016/j.mvr.2011.03.009
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Both spatial variability and temporal variability of skin blood flow are high. Laser speckle contrast imagers (LSCI) allow non-contact, real-time recording of cutaneous blood flow on large skin surfaces. Thereafter, the observer can define different sizes for the region of interest (ROI) in the images to decrease spatial variability and different durations over which the blood flow values are averaged (time of interest, TOI) to decrease temporal variability. We aimed to evaluate the impact of the choices of ROI and TOI on the analysis of rest blood flow and post occlusive reactive hyperemia (PORH). Methods: Cutaneous blood flow (CBF) was assessed at rest and during PORH. Three different sizes of ROI (1 mm(2), 10 mm(2) and 100 mm(2)), and three different TOI (CBF averaged over 1 s, 15s, and 30 s for rest, and over 1 s,5 s and 10 s for PORH peak) were evaluated. Inter-subjects and intra-subjects coefficient of variations (inter-CV and intra-CV) were studied. Results: The inter-subject variability of CBF is about 25% at rest and is moderately improved when the size of the ROI increases (inter-CV = 31%, for 1 s and 1 mm(2) versus inter-CV = 23%, for 15 s and 100 mm(2)). However, increasing the TOI does not improve the results. The variability of the PORH peak is lower with an inter-CV varying between 11.4% (10 s and 100 mm(2)) and 21.6% (5 s and 1 mm(2)). The lowest intra-CV for the CBF at rest was 7.3% (TOI of 15 s on a ROI of 100 mm(2)) and was 3.1% for the PORH peak (TOI of 10 s on a ROI of 100 mm(2)). Conclusion: We suggest that a size of ROI larger than 10 mm(2) and a TOI longer than 1 s are required to reduce the variability of CBF measurements both at rest and during PORH peak evaluations at the forearm level. Many technical aspects such as comparison of laser speckle contrast imaging and laser Doppler imaging or the effect of skin to head distance on recorded values with LCSI are required to improve future studies using this fascinating clinical tool. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:88 / 91
页数:4
相关论文
共 16 条
[1]  
Briers JD, 2007, OPT APPL, V37, P139
[2]   Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging [J].
Briers, JD .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (04) :R35-R66
[3]   Linear response range characterization and in vivo application of laser speckle imaging of blood flow dynamics [J].
Choi, Bernard ;
Ramirez-San-Juan, Julio C. ;
Lotfi, Justin ;
Nelson, J. Stuart .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
[4]   Methodological issues in the assessment of skin microvascular endothelial function in humans [J].
Cracowski, Jean-Luc ;
Minson, Christopher T. ;
Salvat-Melis, Muriel ;
Halliwill, John R. .
TRENDS IN PHARMACOLOGICAL SCIENCES, 2006, 27 (09) :503-508
[5]   Prostaglandins participate in the late phase of the vascular response to acetylcholine iontophoresis in humans [J].
Durand, S ;
Tartas, M ;
Bouyé, P ;
Koïtka, A ;
Saumet, JL ;
Abraham, P .
JOURNAL OF PHYSIOLOGY-LONDON, 2004, 561 (03) :811-819
[6]   Reproducibility of the flow-mediated dilation response to acute exercise in overweight men [J].
Harris, Ryan A. ;
Padilla, Jaume ;
Hanlon, Kevin P. ;
Rink, Lawrence D. ;
Wallace, Janet P. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (10) :1579-1585
[7]  
Holowatz LA, 2008, J APPL PHYSIOL, V105, P370, DOI 10.1152/japplphysiol.00858.2007
[8]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[9]   Characterization of the Non-Invasive Assessment of the Cutaneous Microcirculation by Laser Doppler Perfusion Scanner [J].
Keymel, Stefanie ;
Sichwardt, Julia ;
Balzer, Jan ;
Stegemann, Emilia ;
Rassaf, Tienush ;
Kleinbongard, Petra ;
Kelm, Malte ;
Heiss, Christian ;
Lauer, Thomas .
MICROCIRCULATION, 2010, 17 (05) :358-366
[10]   Human cutaneous reactive hyperaemia:: role of BKCa channels and sensory nerves [J].
Lorenzo, Santiago ;
Minson, Christopher T. .
JOURNAL OF PHYSIOLOGY-LONDON, 2007, 585 (01) :295-303