Pleth Variability Index to Predict Fluid Responsiveness in Colorectal Surgery

被引:77
作者
Hood, Julian A. [1 ]
Wilson, R. Jonathan T. [1 ]
机构
[1] York Hosp, Dept Anesthesia, York YO31 8HE, N Yorkshire, England
关键词
RISK SURGICAL-PATIENTS; PLETHYSMOGRAPHIC WAVE-FORM; ARTERIAL PULSE PRESSURE; STROKE VOLUME VARIATION; ESOPHAGEAL DOPPLER; HOSPITAL STAY; RESPIRATORY VARIATIONS; CARDIAC-OUTPUT; MANAGEMENT; MONITOR;
D O I
10.1213/ANE.0b013e31822c10cd
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Goal-directed fluid therapy during major abdominal surgery may reduce postoperative morbidity. The Pleth Variability Index (PVI), derived from the pulse oximeter waveform, has been shown to be able to predict fluid responsiveness in a number of surgical circumstances. In the present study, we sought to determine whether PVI could predict fluid responsiveness in low-risk colorectal surgery patients who had fluid therapy guided by esophageal Doppler stroke volume measurements. METHODS: Twenty-five low-risk patients undergoing colorectal resection under general anesthesia were studied. Baseline values for esophageal Doppler stroke volume and PVI taken from finger and ear probes were compared with final values after (a) a 500-mL fluid bolus immediately after induction (steady state) and tracheal intubation before the start of the surgery, and (b) 250-mL boluses given in response to a decrease in stroke volume of 10% during surgery as measured by esophageal Doppler (dynamic). Patients were classified into responders and nonresponders based on a stroke volume increase of >10%. RESULTS: Baseline PVI at the finger was significantly higher in responders in both steady-state and intraoperative conditions. In steady state, PVI at both finger and earlobe had significant predictive ability of an increase in stroke volume: area under the curve for finger 0.96 (95% confidence interval [CI], 0.88-1.00; P = 0.011) and for earlobe 0.98 (95% CI, 0.93-1.00; P = 0.008). In dynamic intraoperative conditions, PVI at the finger predicted increases in stroke volume, area under the curve 0.71 (95% CI, 0.57-0.85; P = 0.006), but PVI at the earlobe had no predictive value. CONCLUSIONS: PVI measured at the finger may be able to predict fluid responsiveness during surgery in ventilated patients. (Anesth Analg 2011;113:1058-63)
引用
收藏
页码:1058 / 1063
页数:6
相关论文
共 28 条
[1]   Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery [J].
Abbas, S. M. ;
Hill, A. G. .
ANAESTHESIA, 2008, 63 (01) :44-51
[2]   Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study [J].
Benes, Jan ;
Chytra, Ivan ;
Altmann, Pavel ;
Hluchy, Marek ;
Kasal, Eduard ;
Svitak, Roman ;
Pradl, Richard ;
Stepan, Martin .
CRITICAL CARE, 2010, 14 (03)
[3]   Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation [J].
Biais, M. ;
Nouette-Gaulain, K. ;
Cottenceau, V. ;
Revel, P. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) :761-768
[4]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[5]   Does the pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? [J].
Cannesson, Maxime ;
Delannoy, Bertrand ;
Morand, Antoine ;
Rosamel, Pascal ;
Attof, Yassin ;
Bastien, Olivier ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1189-1194
[6]   The ability of a novel algorithm for automatic estimation of the respiratory variations, in arterial pulse pressure to monitor fluid responsiveness in the operating room [J].
Cannesson, Maxime ;
Slieker, Juliette ;
Desebbe, Olivier ;
Bauer, Christian ;
Chiari, Pascal ;
Henaine, Roland ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1195-1200
[7]   Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery [J].
Conway, DH ;
Mayall, R ;
Abdul-Latif, MS ;
Gilligan, S ;
Tackaberry, C .
ANAESTHESIA, 2002, 57 (09) :845-849
[8]   Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery [J].
Derichard, A. ;
Robin, E. ;
Tavernier, B. ;
Costecalde, M. ;
Fleyfel, M. ;
Onimus, J. ;
Lebuffe, G. ;
Chambon, J. -P. ;
Vallet, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) :678-684
[9]   Goal-Directed Fluid Management Based on the Pulse Oximeter-Derived Pleth Variability Index Reduces Lactate Levels and Improves Fluid Management [J].
Forget, Patrice ;
Lois, Fernande ;
de Kock, Marc .
ANESTHESIA AND ANALGESIA, 2010, 111 (04) :910-914
[10]   Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery [J].
Gan, TJ ;
Soppitt, A ;
Maroof, M ;
El-Moalem, H ;
Robertson, KM ;
Moretti, E ;
Dwane, P ;
Glass, PSA .
ANESTHESIOLOGY, 2002, 97 (04) :820-826