Absolute quantitation of left ventricular wall and cavity parameters using ECG-gated PET

被引:15
作者
Freiberg, J
Hove, JD
Kofoed, KF
Fritz-Hansen, T
Holm, S
Larsson, HB
Kelbæk, H
机构
[1] Univ Copenhagen, Rigshosp, Ctr Heart, Dept Med B,Cardiovasc PET Res Unit,Sect 9201, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Hvidovre Hosp, Danish Res Ctr Magnet Resonance, Copenhagen, Denmark
关键词
positron emission tomography; fluorodeoxyglucose; electrocardiographic gating; left ventricular cardiac volumes; wall motion; wall thickening;
D O I
10.1016/j.nuclcard.2003.09.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Electrocardiography (ECG)-gated scintigraphy demonstrates promising results for the simultaneous assessment of myocardial glucose metabolism and contractile function. In this study a method was evaluated for absolute quantitation of left ventricular wall and cavity parameters with the use of fluorine 18 fluorodeoxyglucose (FDG) ECG-gated positron emission tomography (PET). Methods and Results. A previously developed 2-dimensional mathematical model was implemented for computer-automated identification of endocardial and pericardial borders. The accuracy and precision were tested in a heart phantom and in healthy subjects. Twelve healthy men aged 64 +/- 8 years were studied by use of cine magnetic resonance imaging (MRI) and ECG-gated FDG-PET during euglycemic glucose-insulin clamp. At increasing image noise levels, the estimated cavity volume of the heart phantom was within 2 mL of the actual volume, and no significant difference was found between actual and estimated wall thicknesses. Endocardial wall motion as assessed by ECG-gated PET in the healthy subjects was systematically underestimated compared with MRI. This underestimation correlated linearly with endocardial excursion during PET end diastole as measured by MRI. Myocardial end-diastolic wall thickness was systematically overestimated by PET, whereas end-systolic thickness deviated less than 1 mm from MRI. Cavity volumes measured by PET correlated linearly with. MRI, with a tendency toward an underestimation of end-diastolic cavity volumes by PET. Conclusions. Absolute measures of cardiac structure and function may be obtained with a reasonable degree of accuracy by use of ECG-gated PET imaging. However, a high ECG-gating frequency appears to be required to obtain measurements comparable to what may be achieved by MRI.
引用
收藏
页码:38 / 46
页数:9
相关论文
共 27 条
[1]   Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values [J].
Bavelaar-Croon, CDL ;
Kayser, HWM ;
van der Wall, EE ;
de Roos, A ;
Dibbets-Schneider, P ;
Pauwels, EKJ ;
Germano, G ;
Atsma, DE .
RADIOLOGY, 2000, 217 (02) :572-575
[2]   Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy [J].
Bax, JJ ;
Lamb, H ;
Dibbets, P ;
Pelikan, H ;
Boersma, E ;
Viergever, EP ;
Germano, G ;
Vliegen, HW ;
de Roos, A ;
Pauwels, EKJ ;
Van der Wall, EE .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (12) :1299-1305
[3]   A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Bogaert J, 2001, AM J PHYSIOL-HEART C, V280, pH610
[6]  
COOKE CD, 1994, J NUCL MED, V35, P1185
[7]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[8]  
DEGRADO TR, 1994, J NUCL MED, V35, P1398
[9]  
FABER TL, 1991, J NUCL MED, V32, P2311
[10]  
Gambhir S S, 1990, THESIS U CALIFORNIA