Plasma N-acetylaspartate: Development and validation of a quantitative assay based on HPLC-MS-MS and sample derivatization

被引:8
作者
Campi, Beatrice [1 ]
Codini, Simone [2 ]
Daniele, Giuseppe [2 ]
Marvelli, Antonella [3 ]
Ceccarini, Giovanni [2 ]
Santini, Ferruccio [2 ]
Zucchi, Riccardo [3 ]
Ferrannini, Ele [1 ]
Saba, Alessandro [3 ,4 ]
机构
[1] CNR, Inst Clin Physiol, Pisa, Italy
[2] Univ Pisa, Dept Clin & Expt Med, Pisa, Italy
[3] Univ Pisa, Dept Surg Med & Mol Pathol & Crit Care Med, Pisa, Italy
[4] St Chiara Univ Hosp, Lab Clin Pathol, Pisa, Italy
关键词
N-acetylaspartate; Plasma; Derivatization; Tandem mass spectrometry; Quantification; Validation; L-ASPARTIC ACID; ACETYL-ASPARTATE; ASPARTYLGLUTAMIC ACID; BRAIN; DISEASE; DIAGNOSIS; MATRIX; MS/MS;
D O I
10.1016/j.cca.2020.05.020
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
N-acetylaspartate is a human endogenous compound synthesized by neurons, which is involved in neuronal metabolism. It is used as a marker in brain magnetic resonance spectroscopy to investigate several neurological and metabolic disorders, that can be related to a variation of its concentration with respect to reference values. N-acetylaspartate is present also in biological fluids, such as plasma, urine, and cerebrospinal fluid, where it can be quantified. Here we describe the development and validation, in compliance with the EMA guidelines, of a novel assay method for the quantification of N-acetylaspartate in plasma based on tandem mass spectrometry coupled to liquid chromatography. Its peculiarity lies in the fact that sample preparation includes an esterification step, which significantly improves the chromatographic performances and, consequently, also the method sensitivity, reproducibility and accuracy. Instrumental LLOQ is 0.06 ng/mL, i.e. at least 300 times lower than the medium N-acetylaspartate concentration in samples, accuracy is in the range 98-103%, while precision lies between 1 and 3%. The method robustness was tested in about 1000 injections of plasma samples, 96 of which were used also to assess the reference ranges in control subjects (16.46-63.40 ng/mL). Controls were then compared to plasma samples from type 2 diabetic patients. Contrary to brain magnetic resonance spectroscopy, which demonstrated a decrease in the N-acetylaspartate levels in right frontal and parieto-temporal region of type 2 diabetic patients, plasma analysis showed no statistical difference with respect to controls. However, the method here described can be profitably used in studies concerning different disorders with CNS involvement, as confirmed by reports available in the literature.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 41 条
[1]  
Adalsteinsson E, 2003, AM J NEURORADIOL, V24, P1941
[2]   Quantification of N-acetylaspartic acid in urine by LC-MS/MS for the diagnosis of Canavan disease [J].
Al-Dirbashi, O. Y. ;
Rashed, M. S. ;
Al-Qahtani, K. ;
Al-Mokhadab, M. A. ;
Kurdi, W. ;
Al-Sayed, M. A. A. .
JOURNAL OF INHERITED METABOLIC DISEASE, 2007, 30 (04) :612-612
[3]   HIGH-RESOLUTION PROTON MAGNETIC-RESONANCE SPECTROSCOPY OF HUMAN-BRAIN AND LIVER [J].
BARANY, M ;
SPIGOS, DG ;
MOK, E ;
VENKATASUBRAMANIAN, PN ;
WILBUR, AC ;
LANGER, BG .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :393-398
[4]   N-ACETYL-L-ASPARTIC ACID - A LITERATURE-REVIEW OF A COMPOUND PROMINENT IN H-1-NMR SPECTROSCOPIC STUDIES OF BRAIN [J].
BIRKEN, DL ;
OLDENDORF, WH .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 1989, 13 (01) :23-31
[5]   N-Acetylaspartate Metabolism Outside the Brain: Lipogenesis, Histone Acetylation, and Cancer [J].
Bogner-Strauss, Juliane G. .
FRONTIERS IN ENDOCRINOLOGY, 2017, 8
[6]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[7]   Hydrophilic interaction liquid chromatography (HILIC)-a powerful separation technique [J].
Buszewski, Boguslaw ;
Noga, Sylwia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) :231-247
[8]   Quantification of D-mannose in plasma: Development and validation of a reliable and accurate HPLC-MS-MS method [J].
Campi, Beatrice ;
Codini, Simone ;
Bisoli, Niccolo ;
Baldi, Simona ;
Zucchi, Riccardo ;
Ferrannini, Ele ;
Saba, Alessandro .
CLINICA CHIMICA ACTA, 2019, 493 :31-35
[9]  
CHACE DH, 1993, CLIN CHEM, V39, P66
[10]  
Ciccimaro E, 2010, BIOANALYSIS, V2, P311, DOI [10.4155/bio.09.185, 10.4155/BIO.09.185]