The effects of orifice nozzle number and nozzle made of polyamide plastic and aluminum with different inlet pressures on heating and cooling performance of counter flow Ranque-Hilsch vortex tubes: An experimental investigation

被引:42
作者
Cebeci, Ismail [1 ]
Kirmaci, Volkan [2 ]
Topcuoglu, Umit [3 ]
机构
[1] Turkish Land Forces Noncommissioned Officer Vocat, Balikesir, Turkey
[2] Bartin Univ, Fac Engn Mech Engn, TR-74100 Bartin, Turkey
[3] Bartin Univ, Inst Sci, Mech Engn, TR-74100 Bartin, Turkey
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2016年 / 72卷
关键词
Ranque-Hilsch vortex tube; Energy separation; Cooling; Heating; ENERGY SEPARATION; EXERGY ANALYSIS;
D O I
10.1016/j.ijrefrig.2016.07.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the effects of the orifice nozzle number and the inlet pressure on heating and cooling performance of a counter flow Ranque-Hilsch type vortex tube (RHVT) (L/D ration is 10) are investigated by using air and oxygen as a fluid via an experimental method. Five orifices with two, three, four, five and six nozzles are made from the polyamide plastic and aluminum. The object of this research is to observe thermal behavior of air and oxygen, which are passing through an RHVT. Using two different fluids for each one of the orifices (nozzle numbers), inlet pressure is varied between 150 kPa and 700 kPa by increasing 50 kPa for each step and comparison is made between these two fluids by holding the cold mass fraction constant at 0.36. We show that the temperature gradient between the cold and hot fluid decreases whenever the orifice nozzle number increases. (C) 2016 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:140 / 146
页数:7
相关论文
共 21 条
[1]   The effects of nozzle aspect ratio and nozzle number on the performance of the Ranque-Hilsch vortex tube [J].
Avci, Mete .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :302-308
[2]   A new vortex generator geometry for a counter-flow Ranque-Hilsch vortex tube [J].
Aydin, Orhan ;
Markal, Burak ;
Avci, Mete .
APPLIED THERMAL ENGINEERING, 2010, 30 (16) :2505-2511
[3]   Experimental investigation and exergy analysis of the performance of a counter flow Ranque-Hilsch vortex tube with regard to nozzle cross-section areas [J].
Dincer, K. ;
Avci, A. ;
Baskaya, S. ;
Berber, A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (05) :954-962
[4]   Experimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubes [J].
Dincer, Kevser .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (06) :1366-1371
[5]   Experimental investigation on energy separation in a counter-flow Ranque-Hilsch vortex tube: Effect of cooling a hot tube [J].
Eiamsa-ard, S. ;
Wongcharee, K. ;
Promvonge, P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (02) :156-162
[6]  
Hamdy A. K., 2015, ENERGY, V84, P207
[7]   The influence of working gas characteristics on energy separation of vortex tube [J].
Han, X. ;
Li, N. ;
Wu, K. ;
Wang, Z. ;
Tang, L. ;
Chen, G. ;
Xu, X. .
APPLIED THERMAL ENGINEERING, 2013, 61 (02) :171-177
[8]   Effects of geometric parameters on the separated air flow temperature of a vortex tube for design optimization [J].
Im, S. Y. ;
Yu, S. S. .
ENERGY, 2012, 37 (01) :154-160
[9]   Exergy analysis and performance of a counter flow Ranque-Hilsch vortex tube having various nozzle numbers at different inlet pressures of oxygen and air [J].
Kirmaci, Volkan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07) :1626-1633
[10]   Investigation of the energy separation effect and flow mechanism inside a vortex tube [J].
Liu, Xingwei ;
Liu, Zhongliang .
APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) :494-506