Potentiometric flow injection system for determination of reductants using a polymeric membrane permanganate ion-selective electrode based on current-controlled reagent delivery

被引:7
作者
Song, Wenjing [1 ,2 ]
Ding, Jiawang [1 ]
Liang, Rongning [1 ]
Qin, Wei [1 ]
机构
[1] Chinese Acad Sci, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res, Yantai 264003, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Potentiometry; Flow injection analysis; Ion-selective electrodes; Reductants; Current-controlled release; L-ASCORBIC-ACID; AMINO-ACIDS; COPPER WIRE; FIA SYSTEM; DETECTOR; DOPAMINE; ANIONS;
D O I
10.1016/j.aca.2011.08.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polymeric membrane permanganate-selective electrode has been developed as a current-controlled reagent release system for potentiometric detection of reductants in flow injection analysis. By applying an external current, diffusion of permanganate ions across the polymeric membrane can be controlled precisely. The permanganate ions released at the sample-membrane interface from the inner filling solution of the electrode are consumed by reaction with a reductant in the sample solution thus changing the measured membrane potential, by which the reductant can be sensed potentiometrically. Ascotbate, dopamine and norepinephrine have been employed as the model reductants. Under the optimized conditions, the potential peak heights are proportional to the reductant concentrations in the ranges of 1.0 x 10(-5) to 2.5 x 10(-7) M for ascorbate, of 1.0 x 10(-5) to 5.0 x 10(-7) M for dopamine, and of 1.0 x 10(-5) to 5.0 x 10(-7) M for norepinephrine, respectively with the corresponding detection limits of 7.8 x 10(-8), 1.0 x 10(-7) and 1.0 x 10(-7) M. The proposed system has been successfully applied to the determination of reductants in pharmaceutical preparations and vegetables, and the results agree well with those of iodimetric analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 35 条
[1]   CONTINUOUS-FLOW POTENTIOMETRIC MONITORING OF ALPHA-AMINO-ACIDS WITH COPPER WIRE AND TUBULAR ELECTRODES [J].
ALEXANDER, PW ;
MAITRA, C .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1590-1594
[2]   APPLICATION OF A COPPER TUBULAR ELECTRODE AS A POTENTIOMETRIC DETECTOR IN THE DETERMINATION OF AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALEXANDER, PW ;
HADDAD, PR ;
LOW, GKC ;
MAITRA, C .
JOURNAL OF CHROMATOGRAPHY, 1981, 209 (01) :29-39
[3]   POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF COPPER COMPLEXING INORGANIC ANIONS WITH A COPPER WIRE INDICATOR ELECTRODE [J].
ALEXANDER, PW ;
HADDAD, PR ;
TROJANOWICZ, M .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2417-2422
[4]   INDIRECT POTENTIOMETRIC DETERMINATION OF METAL-IONS BY FLOW-INJECTION ANALYSIS WITH A COPPER ELECTRODE [J].
ALEXANDER, PW ;
TROJANOWICZ, M ;
HADDAD, PR .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (04) :309-320
[5]   Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection - Epinephrine determination in pharmaceutical products [J].
Amorim, C. G. ;
Araujo, A. N. ;
Montenegro, M. C. B. S. M. .
TALANTA, 2007, 72 (04) :1255-1260
[6]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[7]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[8]   Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes [J].
Bakker, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :20-25
[9]   NEW TITRIMETRIC METHOD FOR DETERMINATION OF VITAMIN-C [J].
BARAKAT, MZ ;
SHEHAB, SK ;
DARWISH, N ;
ELZOHEIR.A .
ANALYTICAL BIOCHEMISTRY, 1973, 53 (01) :245-251
[10]   Ion-selective electrode for measuring low Ca2+ concentrations in the presence of high K+, Na+ and Mg2+ background [J].
Bedlechowicz-Sliwakowska, Iwona ;
Lingenfelter, Peter ;
Sokalski, Tomasz ;
Lewenstam, Andrzej ;
Maj-Zurawska, Magdalena .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) :1477-1482