Effect of heat loads and furniture on the thermal comfort of an isolated family house under a naturally ventilated environment

被引:9
作者
Hawendi, Sherzad [1 ,2 ]
Gao, Shian [1 ]
Ahmed, Ahmed Qasim [3 ]
机构
[1] Univ Leicester, Dept Engn, Leicester LE1 7RH, Leics, England
[2] Univ Sulaimani, Engn Coll, Sulaimani, Kurdistan Regio, Iraq
[3] Middle Tech Univ, Engn Tech Coll, Baghdad, Iraq
关键词
Natural ventilation; CFD; heat load; furniture; thermal comfort; INDOOR AIR-QUALITY; CROSS-VENTILATION; CFD SIMULATION; WIND-DRIVEN; PMV MODEL; BUILDINGS; DESIGN; LOCATIONS; FLOWS; OPTIMIZATION;
D O I
10.1080/14733315.2019.1600815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is the most energy-efficient method by which to passively cool a building, reducing the energy consumption, and improving the thermal comfort and indoor air quality. However, designing buildings using cross-ventilation is far more complicated than mere mechanical design due to the indoor and outdoor parameters in addition to the building configurations. The authors have previously reported that the indoor thermal comfort in an isolated family house is affected significantly by the outdoor conditions; the current study, however, focusses on the impact of heat loads and furniture on the indoor thermal comfort. In this work, The Computational Fluid Dynamics (CFD) approach was employed with a coupled indoor-outdoor simulation. The results showed that the heat dissipated from electrical appliances found in daily life only have a small effect on the thermal comfort indices at both the seated and standing levels because they use only relatively small amounts of energy, whereas these indices are increased remarkably at these two levels when an additional heat source was operated in conjunction with these appliances. In addition, no significant differences between the empty building and the furniture-filled building were observed at the two levels when comparing the air velocity, temperature and thermal comfort indices.
引用
收藏
页码:163 / 188
页数:26
相关论文
共 59 条
[1]  
Abiodun O. E., 2014, AM J ENG RES, V3, P63
[2]   Energy saving and indoor thermal comfort evaluation using a novel local exhaust ventilation system for office rooms [J].
Ahmed, Ahmed Qasim ;
Gao, Shian ;
Kareem, Ali Khaleel .
APPLIED THERMAL ENGINEERING, 2017, 110 :821-834
[3]   A numerical study on the effects of exhaust locations on energy consumption and thermal environment in an office room served by displacement ventilation [J].
Ahmed, Ahmed Qasim ;
Gao, Shian ;
Kareem, Ali Khaleel .
ENERGY CONVERSION AND MANAGEMENT, 2016, 117 :74-85
[4]   Design for thermal sensation and comfort states in vehicles cabins [J].
Alahmer, Ali ;
Abdelhamid, Mahmoud ;
Omar, Mohammed .
APPLIED THERMAL ENGINEERING, 2012, 36 :126-140
[5]   PMV-PPD and acceptability in naturally ventilated schools [J].
Alfano, Francesca Romana d'Ambrosio ;
Ianniello, Elvira ;
Palella, Boris Igor .
BUILDING AND ENVIRONMENT, 2013, 67 :129-137
[6]   Design analysis of single-sided natural ventilation [J].
Allocca, C ;
Chen, QY ;
Glicksman, LR .
ENERGY AND BUILDINGS, 2003, 35 (08) :785-795
[7]  
Angelopoulos C, 2017, RES NET 15 C INT
[8]  
Ashrae A. S., 2013, 552013 THERM ENV CON
[9]  
Awbi H., 2003, Ventilation of buildings, DOI 10.4324/9780203634479/ventilation-buildings-awbi
[10]   Envelope Design Optimization by Thermal Modelling of a Building in a Warm Climate [J].
Baglivo, Cristina ;
Congedo, Paolo Maria ;
Di Cataldo, Matteo ;
Coluccia, Luigi Damiano ;
D'Agostino, Delia .
ENERGIES, 2017, 10 (11)