Irreversible hydrocolloid and gypsum interactions

被引:0
|
作者
Reisbick, MH
Johnston, WM
Rashid, RG
机构
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the compatibility of nine popular gypsum products with three more recently developed irreversible hydrocolloid impression materials, some of which were disinfected before pouring. A test die and evaluation procedure conforming to ANSI/ADA specification no. 18 standards were used to evaluate detail reproduction of the impression materials and detail transfer and roughness of the resultant die. Statistical evaluation of the data revealed that there continue to be deleterious surface interactions between specific irreversible hydrocolloid materials and gypsum products. Analysis also confirmed that the phenolic disinfectant used in this study did not influence the surface interaction between materials nor alter the resultant dimensional properties of the gypsums used.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [1] The Effect of Disinfection on Irreversible Hydrocolloid and Type III Gypsum Casts
    Hussain, Syed Mohammed Aun
    Tredwin, Christopher J.
    Nesbit, Michael
    Moles, David R.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2006, 14 (02): : 50 - 54
  • [2] EFFECT OF DISINFECTION ON IRREVERSIBLE HYDROCOLLOID AND ALTERNATIVE IMPRESSION MATERIALS AND THE RESULTANT GYPSUM CASTS
    Suprono, Montry S.
    Kattadiyil, Mathew T.
    Goodacre, Charles J.
    Winer, Myron S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (04): : 250 - 258
  • [3] EFFECTS OF DISINFECTING IRREVERSIBLE HYDROCOLLOID IMPRESSIONS ON THE RESULTANT GYPSUM CASTS - .2. DIMENSIONAL CHANGES
    TAN, HK
    HOOPER, PM
    BUTTAR, IA
    WOLFAARDT, JF
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (06): : 532 - 537
  • [4] EFFECTS OF DISINFECTING IRREVERSIBLE HYDROCOLLOID IMPRESSIONS ON THE RESULTANT GYPSUM CASTS .1. SURFACE QUALITY
    TAN, HK
    WOLFAARDT, JF
    HOOPER, PM
    BUSBY, B
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (03): : 250 - 257
  • [5] Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts
    Taylor, RL
    Wright, PS
    Maryan, C
    DENTAL MATERIALS, 2002, 18 (02) : 103 - 110
  • [6] BOXING IMPRESSIONS WITH IRREVERSIBLE HYDROCOLLOID
    STIPHO, HD
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (05): : 740 - 741
  • [7] THE EFFECT OF POWDER WATER RATIO OF IRREVERSIBLE HYDROCOLLOID ON THE BOND STRENGTH OF IRREVERSIBLE HYDROCOLLOID AND AGAR COMBINATIONS
    LEWINSTEIN, I
    CRAIG, RG
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04): : 412 - 416
  • [8] THE COMBINED REVERSIBLE HYDROCOLLOID-IRREVERSIBLE HYDROCOLLOID IMPRESSION SYSTEM
    APPLEBY, DC
    PAMEIJER, CH
    BOFFA, J
    JOURNAL OF PROSTHETIC DENTISTRY, 1980, 44 (01): : 27 - 35
  • [9] A BOXING TECHNIQUE FOR IRREVERSIBLE HYDROCOLLOID IMPRESSIONS
    MACHNEE, CH
    LONEY, RW
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (05): : 610 - 612
  • [10] QUICK BOXING OF IMPRESSIONS WITH IRREVERSIBLE HYDROCOLLOID
    HAMADA, MO
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (06): : 743 - 745