Metal ion levels in patients with a lumbar metal-on-metal total disc replacement SHOULD WE BE CONCERNED?

被引:21
|
作者
Bisseling, P. [1 ]
Zeilstra, D. J. [1 ]
Hol, A. M. [1 ]
van Susante, J. L. C. [1 ]
机构
[1] Rijnstate Hosp, Dept Orthopaed, NL-6800 TA Arnhem, Netherlands
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2011年 / 93B卷 / 07期
关键词
SERUM FOLLOWING IMPLANTATION; TOTAL HIP-REPLACEMENT; CHROMIUM IONS; ARTHROPLASTY; BEARINGS; RELEASE; COBALT; PSEUDOTUMORS; COMPONENT; WEAR;
D O I
10.1302/0301-620X.93B7.26392
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR). Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR. Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p < 0.001). Both chromium levels were also significantly lower after TDR versus hip resurfacing (p < 0.001), whereas compared with THR this difference was only significant for serum levels (p = 0.008). All metal ion levels in the THR and resurfacing groups were significantly higher than in the control group (p < 0.001). In the TDR group only cobalt in whole blood appeared to be significantly higher (p < 0.001). The median range of movement of the TDR was 15.5 degrees (10 degrees to 22 degrees). These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 50 条
  • [1] Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty
    Gornet, Matthew F.
    Burkus, J. K.
    Harper, M. L.
    Chan, F. W.
    Skipor, A. K.
    Jacobs, J. J.
    EUROPEAN SPINE JOURNAL, 2013, 22 (04) : 741 - 746
  • [2] Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty
    Matthew F. Gornet
    J. K. Burkus
    M. L. Harper
    F. W. Chan
    A. K. Skipor
    J. J. Jacobs
    European Spine Journal, 2013, 22 : 741 - 746
  • [3] Prospective, randomized trial of metal-on-metal artificial lumbar disc replacement
    Sasso, Rick C.
    Foulk, David M.
    Hahn, Michael
    SPINE, 2008, 33 (02) : 123 - 131
  • [4] Metal-on-Metal Lumbar Total Disc Arthroplasty: Ready for Prime Time?
    Wang, Michael Y.
    WORLD NEUROSURGERY, 2012, 78 (3-4) : 247 - 247
  • [5] Delayed hypersensitivity reaction caused by metal-on-metal total disc replacement
    Zairi, Fahed
    Remacle, Jean Michel
    Allaoui, Mohamed
    Assaker, Richard
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (03) : 389 - 391
  • [6] Metal-on-metal total hip replacement
    Silva, M
    Heisel, C
    Schmalzried, TP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 53 - 61
  • [7] The effect of obesity on blood metal ion levels after hip resurfacing and metal-on-metal total hip replacement
    Sawalha, Seif
    Ravikumar, Raveena
    Chowdhury, Emyr A.
    Massraf, Araz
    HIP INTERNATIONAL, 2012, 22 (01) : 107 - 112
  • [8] Wear in metal-on-metal total disc arthroplasty
    Shepherd, D.E.T. (d.e.shepherd@bham.ac.uk), 1600, SAGE Publications Ltd (227):
  • [9] Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients
    Matharu, Gulraj S.
    Berryman, Fiona
    Brash, Lesley
    Pynsent, Paul B.
    Treacy, Ronan B.
    Dunlop, David J.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1803 - 1811
  • [10] Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients
    Gulraj S. Matharu
    Fiona Berryman
    Lesley Brash
    Paul B. Pynsent
    Ronan B. Treacy
    David J. Dunlop
    International Orthopaedics, 2015, 39 : 1803 - 1811