Influence analysis of building types and climate zones on energetic, economic and environmental performances of BCHP systems

被引:104
作者
Wang, Jiangjiang [1 ]
Zhai, Zhiqiang [2 ]
Jing, Youyin [1 ]
Zhang, Chunfa [1 ]
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding 071003, Hebei, Peoples R China
[2] Univ Colorado, Dept Civil Environm & Architectural Engn, Boulder, CO 80309 USA
关键词
Building cooling heating and power (BCHP) system; Building type; Climate zone; Energy; Economy; Environment; PARTICLE SWARM OPTIMIZATION; OPTIMAL OPERATION; OPTIMAL-DESIGN; TRIGENERATION SYSTEMS; COGENERATION SYSTEMS; GENERATION SYSTEMS; PROGRAMMING-MODEL; POWER; CCHP; EVOLUTIONARY;
D O I
10.1016/j.apenergy.2011.03.016
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of building cooling heating and power (BCHP) system is obviously dependent upon the seasonal atmospheric conditions and the building types. This paper presents the energy flow analysis and the evaluation criteria of the redundant BCHP system and describes the optimal design method. The BCHP systems for four building categories (Hotel, Office, Hospital and School) in five climate zones (Severe Cold Zone, Cold Zone, Hot Summer and Cold Winter Zone, Mild Zone and Hot Summer and Warm Winter Zone) in China are compared and evaluated from energetic, economic and environmental aspects. The comparison results show that the BCHP system is generally suitable for the building, which operates for long time over the entire year, in the climate zone where buildings require more heat for space heating. Moreover, the influence analysis on BCHP capacity and operation strategy indicates that the capacity of power generation unit (PGU) is the most sensitive design parameter to influence the integrated performance of the BCHP system. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3097 / 3112
页数:16
相关论文
共 59 条
[1]  
[Anonymous], BASE LINE INVESTIGAT
[2]  
[Anonymous], COOP FIN SERV SUST R
[3]  
[Anonymous], INNOV SWARM INTELL
[4]  
[Anonymous], EPA GREEN BUILD STRA
[5]  
[Anonymous], 2006, BUILDING ENV SYSTEM
[6]   A mixed integer programming model for optimal design of trigeneration in a hospital complex [J].
Arcuri, P. ;
Florio, G. ;
Fragiacomo, P. .
ENERGY, 2007, 32 (08) :1430-1447
[7]   Optimal operation of industrial cogeneration for load management [J].
Ashok, S ;
Banerjee, R .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) :931-937
[8]   A multi-objective chaotic particle swarm optimization for environmental/economic dispatch [J].
Cai, Jiejin ;
Ma, Xiaoqian ;
Li, Qiong ;
Li, Lixiang ;
Peng, Haipeng .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) :1318-1325
[9]   China building energy consumption: Situation, challenges and corresponding measures [J].
Cai, W. G. ;
Wu, Y. ;
Zhong, Y. ;
Ren, H. .
ENERGY POLICY, 2009, 37 (06) :2054-2059
[10]   Evaluation of retrofitting gas-fired cooling and heating systems into BCHP using design optimization [J].
Cao, Jiacong .
ENERGY POLICY, 2009, 37 (06) :2368-2374