Cardiac gated images often suffer from increased noise in single photon emission computed tomography (SPECT) due to reduced data counts compared to non-gated studies. We investigate a spatiotemporal post-processing approach based on a non-local means (NLM) filter for suppressing the noise in gated SPECT images. In this filter, the output at a voxel location is computed from a weighted average of voxels in its four-dimensional (4D) neighborhood, wherein the filter coefficients are adjusted according to the similarity level in the local image pattern of individual voxels with respect to the output voxel. This adaptive property allows the filter to achieve noise reduction while avoiding excessive blur of the heart wall. In the experiments, we first evaluated the accuracy of the proposed NLM filtering approach using simulated SPECT imaging data. We then demonstrated the approach on eight sets of clinical acquisitions. In addition, we also explored the robustness of the NLM filter with imaging dose reduced by 50% in these clinical acquisitions. The quantitative results show that 4D NLM filtering could effectively reduce the noise level in gated images, leading to more accurate reconstruction of the myocardium. Compared to spatial filtering alone, using temporal filtering in NLM could reduce the mean-squared-error of the myocardium by 55.63% and improve the left ventricle resolution by 19.92%. It could also improve the visibility of perfusion defects in gated images. Similar results are also observed on the clinical acquisitions both at standard dose and at 50% reduced dose. The 4D NLM results are also found to be comparable to that of a motion-compensated 4D reconstruction approach which is computationally more demanding.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Non-local Means Resolution Enhancement of Lung 4D-CT Data
    Zhang, Yu
    Wu, Guorong
    Yap, Pew-Thian
    Feng, Qianjin
    Lian, Jun
    Chen, Wufan
    Shen, Dinggang
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 214 - 222
  • [42] Non-local means image denoising with multi-stage residual filtering
    Sun W.
    Dai Y.
    Sun, Weifeng (swf0217@163.com), 1999, Science Press (38): : 1999 - 2006
  • [43] SAR Tomography with Improved Non-Local Means Filtering Based on Adaptive Window
    Shenglei Wang
    Zhiyang Chen
    Yuanhao Li
    Cheng Hu
    Journal of Beijing Institute of Technology, 2023, 32 (06) : 670 - 684
  • [44] VIRTUAL VIEW SYNTHESIS BY NON-LOCAL MEANS FILTERING USING TEMPORAL DATA
    Krishnamurthy, Suraj
    Ramakrishnan, Kalpathi R.
    2014 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO (3DTV-CON), 2014,
  • [45] Two-stage non-local means filtering with adaptive smoothing parameter
    Zhu, Shujin
    Li, Yuehua
    Li, Yuanjiang
    OPTIK, 2014, 125 (23): : 7040 - 7044
  • [46] Image-based Material Restyling With Fast Non-local Means Filtering
    Sheng, Bin
    Li, Ping
    Sun, Hanqiu
    PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON IMAGE AND GRAPHICS (ICIG 2009), 2009, : 841 - 846
  • [47] Depth Image Inpainting Algorithm Based on Improved Non-Local Means Filtering
    Chen, Jian
    Zhang, Jianfeng
    2024 5TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND APPLICATION, ICCEA 2024, 2024, : 964 - 967
  • [48] Motion-compensated 4D processing of gated SPECT perfusion studies
    Brankov, JG
    Yang, YY
    Narayanan, MV
    Wernick, MN
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1380 - 1384
  • [49] Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT
    Lalush, DS
    Tsui, BMW
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 875 - 886