4D non-local means post-filtering for cardiac gated SPECT

被引:5
|
作者
Song, Chao [1 ]
Yang, Yongyi [1 ]
Pretorius, P. Hendrik [2 ]
King, Michael A. [2 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] Univ Massachusetts, Med Sch, Dept Radiol, Worcester, MA 01605 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
基金
美国国家卫生研究院;
关键词
cardiac-gated SPECT; non-local means filter; spatiotemporal processing; 4D reconstruction; MOTION ESTIMATION; RECONSTRUCTION; ALGORITHM; SCATTER; IMAGES;
D O I
10.1088/1361-6560/aaa44d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiac gated images often suffer from increased noise in single photon emission computed tomography (SPECT) due to reduced data counts compared to non-gated studies. We investigate a spatiotemporal post-processing approach based on a non-local means (NLM) filter for suppressing the noise in gated SPECT images. In this filter, the output at a voxel location is computed from a weighted average of voxels in its four-dimensional (4D) neighborhood, wherein the filter coefficients are adjusted according to the similarity level in the local image pattern of individual voxels with respect to the output voxel. This adaptive property allows the filter to achieve noise reduction while avoiding excessive blur of the heart wall. In the experiments, we first evaluated the accuracy of the proposed NLM filtering approach using simulated SPECT imaging data. We then demonstrated the approach on eight sets of clinical acquisitions. In addition, we also explored the robustness of the NLM filter with imaging dose reduced by 50% in these clinical acquisitions. The quantitative results show that 4D NLM filtering could effectively reduce the noise level in gated images, leading to more accurate reconstruction of the myocardium. Compared to spatial filtering alone, using temporal filtering in NLM could reduce the mean-squared-error of the myocardium by 55.63% and improve the left ventricle resolution by 19.92%. It could also improve the visibility of perfusion defects in gated images. Similar results are also observed on the clinical acquisitions both at standard dose and at 50% reduced dose. The 4D NLM results are also found to be comparable to that of a motion-compensated 4D reconstruction approach which is computationally more demanding.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Joint Bilateral Filtering based Non-local Means Image Denoising
    Jith, O. U. Nirmal
    Babu, R. Venkatesh
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS (SPCOM), 2014,
  • [32] A PULL-PUSH METHOD FOR FAST NON-LOCAL MEANS FILTERING
    Isidoro, John R.
    Milanfar, Peyman
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2016, : 1968 - 1972
  • [33] Adaptive Image Denoising Method Based On Non-local Means Filtering
    Wang, Jing
    Su, Jia
    Hou, Yan-li
    Hou, Wei-min
    2015 7TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION AND CONTROL (ICMIC), 2014, : 624 - 627
  • [34] Adaptive non-local means filtering based on local noise level for CT denoising
    Li, Zhoubo
    Yu, Lifeng
    Trzasko, Joshua D.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Manduca, Armando
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [35] MULTICYCLE NON-LOCAL MEANS DENOISING OF CARDIAC IMAGE SEQUENCES
    Batikian, John M.
    Liebling, Michael
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 1071 - 1074
  • [36] A Non-Local Means Post-Filter with Spatially Adaptive Filtering Strength for Whole-Body PET
    Qi, Wenyuan
    Xia, Ting
    Niu, Xiaofeng
    Ji, Changguo
    Winkler, Mark
    Asma, Evren
    Wang, Wenli
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [37] APPROXIMATE 4D RECONSTRUCTION OF CARDIAC-GATED SPECT IMAGES USING A RESIDUAL CONVOLUTIONAL NEURAL NETWORK
    Song, Chao
    Yang, Yongyi
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    2019 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2019, : 1262 - 1266
  • [38] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography:: validation using a dynamic cardiac phantom
    Debrun, D
    Thérain, F
    Nguyen, LD
    Léger, C
    Visser, J
    Busemann-Sokole, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 239 - 247
  • [39] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom
    Dominique Debrun
    Fabienne Thérain
    Long-Dang Nguyen
    Christophe P. Léger
    Jacco J. N. Visser
    The International Journal of Cardiovascular Imaging, 2005, 21 : 239 - 247
  • [40] 4D reconstruction of cardiac gated SPECT images using a content-adaptive deformable mesh model
    Marin, Thibault
    Wernick, Miles N.
    Yang, Yongyi
    Brankov, Jovan G.
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623