Forward light scatter and contrast sensitivity in keratoconic patients

被引:30
作者
Jinabhai, Amit [1 ]
O'Donnell, Clare [1 ]
Radhakrishnan, Hema [1 ]
Nourrit, Vincent [1 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
关键词
Keratoconus; Light-scattering; Straylight; Glare; HIGHER-ORDER ABERRATIONS; INTRAOCULAR STRAY LIGHT; CONTACT-LENS CORRECTION; PENETRATING KERATOPLASTY; VISUAL FUNCTION; LONGITUDINAL EVALUATION; CONFOCAL MICROSCOPY; RETINAL STRAYLIGHT; CATARACT PATIENTS; CORNEAS;
D O I
10.1016/j.clae.2011.07.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to obtain intraocular forward light scatter (FLS) data in keratoconus patients and to explore possible relationships with contrast sensitivity. Method: Intraocular straylight was assessed in the right eye of 10 visually-normal subjects (31 +/- 5 years) and 5 keratoconus patients (34 +/- 9 years) using the van den Berg straylight meter. Contrast sensitivity was also measured in both groups, with and without a glare source provided by the Brightness Acuity Tester (BAT), using a Pelli-Robson chart. Inclusion criteria for the keratoconic patients were chosen to avoid natural causes of increased scatter and to limit the influence of factors that could affect the straylight measurements. Results: Intraocular light scatter was significantly greater in the keratoconic patients than in normal subjects for each of the three eccentricities tested (Mann-Whitney U test (2-tailed): Z <= -2.2, p <= 0.027). Baseline Pelli-Robson contrast sensitivity was also found to be lower in the keratoconus group than in the normal subjects (Mann-Whitney U test: Z = -2.2, p = 0.023). Under glare conditions contrast loss was significantly greater in the keratoconic patients than in the normal subjects (Mann-Whitney U test: Z = -2.5, p = 0.013). High levels of negative correlation were found between the magnitudes of intraocular straylight and baseline contrast sensitivity in the keratoconus group (Spearman's correlation coefficient (R-S) <= -0.87, p <= 0.027). Conclusion: The high values of straylight measured in the keratoconic patients cannot be explained by age or scarring and could be related to the structural degradation of the cornea. Further investigation of intraocular scatter in keratoconus is warranted to improve our current understanding of the visual deficits associated with this pathology. (C) 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 78 条
[1]  
BARR J.T., 1991, INT CONT LENS CLIN, V22, P173
[2]  
Barrett B, 1996, OPHTHAL PHYSL OPT, V16, P255
[3]   Straylight values 1 month after laser in situ keratomileusis and photorefractive keratectomy [J].
Beerthuizen, Jeroen J. G. ;
Franssen, Luuk ;
Landesz, Monika ;
van den Berg, Thomas J. T. P. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :779-783
[4]   Visual function after penetrating keratoplasty for keratoconus: a prospective longitudinal evaluation [J].
Brahma, A ;
Ennis, F ;
Harper, R ;
Ridgway, A ;
Tullo, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (01) :60-66
[5]   Defining subclinical keratoconus using corneal first-surface higher-order aberrations [J].
Buehren, Jens ;
Kuehne, Christoph ;
Kohnen, Thomas .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :381-389
[6]   Diffraction haloes resulting from corneal oedema and epithelial cell size [J].
Caldicott, A ;
Charman, WN .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (03) :209-213
[7]  
CARNEY LG, 1982, ARCH OPHTHALMOL-CHIC, V100, P1282
[8]  
CARNEY LG, 1982, ACTA OPHTHALMOL, V60, P795
[9]   VISUAL LOSSES AFTER MYOPIC EPIKERATOPLASTY [J].
CARNEY, LG ;
KELLEY, CG .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (04) :499-502
[10]  
Carney LG, 1991, EYE CONT LENS, V17, P52