A ten-year follow-up of the Reflection cementless acetabular component

被引:15
作者
Civinini, R. [1 ]
D'Arienzo, M. [1 ]
Innocenti, M. [1 ]
机构
[1] Univ Florence, Orthopaed Clin 2, I-50139 Florence, Italy
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 05期
关键词
D O I
10.1302/0301-620X.90B5.20116
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a revision, minor osteolytic lesions of the pelvis were seen in six (5.9%). Kaplan-Meier survival analysis for the total cohort of 118 hips revealed a 96.4% survival at both ten (95% confidence interval 90 to 98) and 12 years (95% confidence interval 86 to 98).
引用
收藏
页码:570 / 573
页数:4
相关论文
共 32 条
[1]  
BOBYN JD, 1994, CLIN ORTHOP RELAT R, P27
[2]  
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[3]   Second-generation porous-coated cementless total hip arthroplasties have high survival [J].
Chen, Christopher J. ;
Xenos, John S. ;
McAuley, James P. ;
Young, Anthony ;
Engh, Charles A., Sr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :121-127
[4]  
CHEN PC, 1995, CLIN ORTHOP RELAT R, P44
[5]  
CHMELL MJ, 1995, CLIN ORTHOP RELAT R, P77
[6]   Pattern of osteolysis around two different cementless metal-backed cups - Retrospective, radiographic analysis at minimum 10-year follow-up [J].
Claus, AM ;
Sychterz, CJ ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :177-182
[7]   Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[8]   Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old - Results at nine to fourteen years [J].
Crowther, JD ;
Lachiewicz, PF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (05) :729-735
[9]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]   Backside wear is low in retrieved modern, modular, and nonmodular acetabular liners [J].
Della Valle, AG ;
Rana, A ;
Furman, B ;
Sculco, TP ;
Salvati, EA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :184-191