New technique for application of fibrin sealant: Rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes

被引:39
作者
Nakajima, S
Fukuda, T
Hasue, M
Sengoku, Y
Haraoka, J
Uchida, T
机构
[1] Hachioji Med Ctr, Dept Neurosurg, Tokyo, Japan
[2] Tokyo Med Univ, Dept Neurosurg, Tokyo, Japan
[3] Chemo Sero Therapeut Res Inst, Kumamoto, Japan
关键词
cerebrospinal fluid leakage; expanded polytetrafluoroethylene surgical membrane; fibrin sealant;
D O I
10.1097/00006123-200107000-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The effectiveness of a strong, pressure-tight method for fibrin sealant application was experimentally and clinically evaluated, using expanded polytetrafluoroethylene (ePTFE) surgical membranes. METHODS: Two application methods were examined in two groups. For Group 1, 1 ml each of Solutions A and B was simply sprayed over the surface (spray method). For Group 2, a small amount of Solution A was rubbed into the sutured site and then Solutions A and B were sprayed over the surface (rubbing method). In the experimental study, a moment pressure elevation test and a continuous stepwise pressure elevation test were performed for both groups. The clinical study was conducted using 350 patients undergoing craniotomies. The ePTFE surgical membrane was used for 180 patients but not the other 170 patients. RESULTS: In the experimental study, the bursting pressures were 51.4 +/- 13.0 cm H2O for Group 1 and 129 +/- 35.0 cm H2O for Group 2 in the moment pressure elevation test and 27.0 +/- 6.7 cm H2O and 100 +/- 31.9 cm H2O, respectively, in the continuous stepwise pressure elevation test. The sealing effect was significantly greater for Group 2 than for Group 1 in both tests (P < 0.001). In the clinical study using ePTFE surgical membranes, the rubbing method significantly reduced the incidence of postoperative cerebrospinal fluid leakage (1.4%), compared with the spray method (18.3%), when external decompression was not concomitantly used (P < 0.01). CONCLUSION: The sealing effect of fibrin sealant on cerebrospinal fluid leakage was significantly greater with the rubbing method than with the spray method. The strong sealing effect obtained with the rubbing method is thought to result from firm linkage between the ePTFE surgical membrane and the fibrin sealant and also from fibrin being formed even in needle holes and spaces in the sutured site.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 12 条
  • [1] GORTLER M, 1991, NEUROCHIRURGIA, V34, P103
  • [2] HATANAKA M, 1992, RES NEW MED DEV, V1, P183
  • [3] Treatment of postoperative subgaleal cerebrospinal fluid fistulas by using fibrin sealant
    Menovsky, T
    de Vries, J
    Bloss, HG
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (06) : 1143 - 1145
  • [4] Nagata K, 1999, NEUROL MED-CHIR, V39, P316, DOI 10.2176/nmc.39.316
  • [5] NISHIHIRA S, 1988, LARYNGOSCOPE, V98, P625
  • [6] Evaluation of application techniques of fibrin sealant to prevent cerebrospinal fluid leakage: A new device for the application of aerosolized fibrin clue
    Sawamura, Y
    Asaoka, K
    Terasaka, S
    Tada, M
    Uchida, T
    [J]. NEUROSURGERY, 1999, 44 (02) : 332 - 337
  • [7] NEUROSURGICAL APPLICATIONS OF FIBRIN GLUE - AUGMENTATION OF DURAL CLOSURE IN 134 PATIENTS
    SHAFFREY, CI
    SPOTNITZ, WD
    SHAFFREY, ME
    JANE, JA
    [J]. NEUROSURGERY, 1990, 26 (02) : 207 - 210
  • [8] SIERRA DH, 1990, LARYNGOSCOPE, V100, P360
  • [9] CEREBROSPINAL-FLUID RHINORRHEA FOLLOWING ACOUSTIC NEURINOMA SURGERY - TECHNICAL NOTE
    SYMON, L
    PELL, MF
    [J]. JOURNAL OF NEUROSURGERY, 1991, 74 (01) : 152 - 153
  • [10] FIBRIN TISSUE ADHESIVE SEALANT FOR THE PREVENTION OF CSF LEAKAGE FOLLOWING TRANSSPHENOIDAL MICROSURGERY
    VANVELTHOVEN, V
    CLARICI, G
    AUER, LM
    [J]. ACTA NEUROCHIRURGICA, 1991, 109 (1-2) : 26 - 29