Breast Cancer Screening with Digital Breast Tomosynthesis: Are Initial Benefits Sustained?

被引:26
作者
Bahl, Manisha [1 ]
Mercaldo, Sarah [2 ]
Dang, Pragya A. [1 ,4 ]
Mccarthy, Anne Marie [3 ,5 ]
Lowry, Kathryn P. [1 ,6 ]
Lehman, Constance D. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St,WAC 240, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Inst Technol Assessment, 55 Fruit St,WAC 240, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Dept Med, 55 Fruit St,WAC 240, Boston, MA 02114 USA
[4] Newton Wellesley Hosp, Dept Radiol, Newton, MA USA
[5] Univ Penn, Dept Biostat Epidemiol & Informat, Philadelphia, PA 19104 USA
[6] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
MAMMOGRAPHY; 2D-MAMMOGRAPHY; IMPLEMENTATION; COMBINATION; OUTCOMES;
D O I
10.1148/radiol.2020191030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Performance metrics with digital breast tomosynthesis (DBT) are based on early experiences. There is limited research on whether the benefits of DBT are sustained. Purpose: To determine whether improved screening performance metrics with DBT are sustained over time at the population level and after the first screening round at the individual level. Materials and Methods: A retrospective review was conducted of screening mammograms that had been obtained before DBT implementation(March 2008 to February 2011, two-dimensional digital mammography [DM] group) and for 5 years after implementation(January 2013 to December 2017, DBT1-DBT5 groups, respectively). Patients who underwent DBT were also categorized according to the number of previous DBT examinations they had undergone. Performance metrics were compared between DM and DBT groups and between patients with no previous DBT examinations and those with at least one prior DBT examination by using multivariable logistic regression models. Results: The DM group consisted of 99 582 DM examinations in 55 086 women (mean age, 57.3 years +/- 11.6 [standard deviation]). The DBT group consisted of 205 048 examinations in 76 276 women (mean age, 58.2 years +/- 11.2). There were no differences in the cancer detection rate (CDR) between DM and DBT groups (4.6-5.8 per 1000 examinations, P =.08 to P =.95). The highest CDR was observed with a woman's first DBT examination (6.1 per 1000 examinations vs 4.4-5.7 per 1000 examinations with atleast one prior DBT examination, P =.001 to P =.054). Compared with the DM group, the DBT1 group had a lower abnormal interpretation rate (AIR) (adjusted odds ratio [AOR], 0.85; P < .001), which remained reduced in the DBT2, DBT3, and DBT5 groups (P < .001 to P =.02). The reduction in AIR was also sustained after the first examination (P < .001 to P =.002).Compared with the DM group, the DBT1 group had a higher specificity (AOR, 1.20; P < .001), which remained increased inDBT2, DBT3, and DBT5 groups (P < .001 to P =.004). The increase in specificity was also sustained after the first examination(P < .001 to P =.01). Conclusion: The benefits of reduced false-positive examinations and higher specificity with screening tomosynthesis were sustained after the first screening round at the individual level. (C) RSNA, 2020
引用
收藏
页码:529 / 539
页数:11
相关论文
共 29 条
[1]   A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial [J].
Aase, Hildegunn S. ;
Holen, Asne S. ;
Pedersen, Kristin ;
Houssami, Nehmat ;
Haldorsen, Ingfrid S. ;
Sebuodegard, Sofie ;
Hanestad, Berit ;
Hofvind, Solveig .
EUROPEAN RADIOLOGY, 2019, 29 (03) :1175-1186
[2]   Digital 2D versus Tomosynthesis Screening Mammography among Women Aged 65 and Older in the United States [J].
Bahl, Manisha ;
Pinnamaneni, Niveditha ;
Mercaldo, Sarah ;
McCarthy, Anne Marie ;
Lehman, Constance D. .
RADIOLOGY, 2019, 291 (03) :582-590
[3]   Breast Cancer Characteristics Associated with 2D Digital Mammography versus Digital Breast Tomosynthesis for Screening-detected and Interval Cancers [J].
Bahl, Manisha ;
Gaffney, Shannon ;
McCarthy, Anne Marie ;
Lowry, Kathryn P. ;
Dang, Pragya A. ;
Lehman, Constance D. .
RADIOLOGY, 2018, 287 (01) :49-57
[4]   Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time [J].
Bernardi, D. ;
Ciatto, S. ;
Pellegrini, M. ;
Anesi, V. ;
Burlon, S. ;
Cauli, E. ;
Depaoli, M. ;
Larentis, L. ;
Malesani, V. ;
Targa, L. ;
Baldo, P. ;
Houssami, N. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) :E1174-E1178
[5]   Effect of integrating 3D-mammography (digital breast tomosynthesis) with 2D-mammography on radiologists' true-positive and false-positive detection in a population breast screening trial [J].
Bernardi, Daniela ;
Caumo, Francesca ;
Macaskill, Petra ;
Ciatto, Stefano ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Houssami, Nehmat .
EUROPEAN JOURNAL OF CANCER, 2014, 50 (07) :1232-1238
[6]   Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program [J].
Caumo, Francesca ;
Zorzi, Manuel ;
Brunelli, Silvia ;
Romanucci, Giovanna ;
Rella, Rossella ;
Cugola, Loredana ;
Bricolo, Paola ;
Fedato, Chiara ;
Montemezzi, Stefania ;
Houssami, Nehmat .
RADIOLOGY, 2018, 287 (01) :37-46
[7]   Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: Increased breast cancer detection evident for screening centres in a population-based trial [J].
Caumo, Francesca ;
Bernardi, Daniela ;
Ciatto, Stefano ;
Macaskill, Petra ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Houssami, Nehmat .
BREAST, 2014, 23 (01) :76-80
[8]   Association of Digital Breast Tomosynthesis vs Digital Mammography With Cancer Detection and Recall Rates by Age and Breast Density [J].
Conant, Emily F. ;
Barlow, William E. ;
Herschorn, Sally D. ;
Weaver, Donald L. ;
Beaber, Elisabeth F. ;
Tosteson, Anna N. A. ;
Haas, Jennifer S. ;
Lowry, Kathryn P. ;
Stout, Natasha K. ;
Trentham-Dietz, Amy ;
diFlorio-Alexander, Roberta M. ;
Li, Christopher I. ;
Schnall, Mitchell D. ;
Onega, Tracy ;
Sprague, Brian L. ;
Haas, Jennifer S. ;
Onega, Tracy ;
Tosteson, Anna N. A. ;
Birdwell, Robyn ;
Khorasani, Ramin ;
Lacson, Ronilda ;
Ozanne, Elissa ;
Tosteson, Tor D. ;
Bronson, Mackenzie ;
Chen, Jane ;
Goodrich, Martha ;
Harris, Kimberly A. ;
St Hubert, Stella ;
Pearson, Loretta ;
Andrews, Steven ;
Anton, Kristen ;
Batcho, Katrine ;
Brawarsky, Phyllis ;
Cook, Charles ;
Das, Amar ;
Dougher, Ryan ;
Eliassen, Scottie ;
Farr, Scott ;
Felone, Carol ;
Frazee, Tracy ;
Gerlach, Scott ;
Getty, George ;
Gilman, John ;
Hanson, Dick ;
Johnson, Dennis ;
Joseph, Brenda ;
Laam, Leslie A. ;
Levin, Brian ;
Pyle, Steven ;
Sims-Larabee, Laura .
JAMA ONCOLOGY, 2019, 5 (05) :635-642
[9]   Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium [J].
Conant, Emily F. ;
Beaber, Elisabeth F. ;
Sprague, Brian L. ;
Herschorn, Sally D. ;
Weaver, Donald L. ;
Onega, Tracy ;
Tosteson, Anna N. A. ;
McCarthy, Anne Marie ;
Poplack, Steven P. ;
Haas, Jennifer S. ;
Armstrong, Katrina ;
Schnall, Mitchell D. ;
Barlow, William E. .
BREAST CANCER RESEARCH AND TREATMENT, 2016, 156 (01) :109-116
[10]   Addition of Tomosynthesis to Conventional Digital Mammography: Effect on Image Interpretation Time of Screening Examinations [J].
Dang, Pragya A. ;
Freer, Phoebe E. ;
Humphrey, Kathryn L. ;
Halpern, Elkan F. ;
Rafferty, Elizabeth A. .
RADIOLOGY, 2014, 270 (01) :49-56