Multiscale optimization of the probe placement for radiofrequency ablation

被引:33
作者
Altrogge, Inga [1 ]
Preusser, Tobias
Kroeger, Tim
Bueskens, Christof
Pereira, Philippe L.
Schmidt, Diethard
Peitgen, Heinz-Otto
机构
[1] Univ Bremen, Ctr Complex Syst & Visualizat, D-2800 Bremen 33, Germany
[2] Univ Bremen, Ctr Ind Math, D-2800 Bremen, Germany
[3] Univ Tubingen, Dept Diagnost Radiol, D-72074 Tubingen, Germany
关键词
D O I
10.1016/j.acra.2007.07.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We present a model for the optimal placement of mono- and bipolar probes in radiofrequency (RF) ablation. The model is based on a system of partial differential equations that describe the electric potential of the probe and the steady state of the induced heat distribution. Materials and Methods. To optimize the probe placement we minimize a temperature-based objective function under the constraining system of partial differential equations. Further, the extension of the resulting optimality system for the use of multiple coupled RF probes is discussed. We choose a multiscale gradient descent approach to solve the optimality system. Results. This article describes the discretization and implementation of the approach with finite elements on three-dimensional hexahedral grids. Conclusion. Applications of the optimization to artificial test scenarios as well as a comparison to a real RF ablation show the usefulness of the approach.
引用
收藏
页码:1310 / 1324
页数:15
相关论文
共 50 条
[1]   Towards optimization of probe placement for radio-frequency ablation [J].
Altrogge, Inga ;
Kroeger, Tim ;
Preusser, Tobias ;
Bueskens, Christof ;
Pereira, Philippe L. ;
Schmidt, Diethard ;
Weihusen, Andreas ;
Peitgen, Heinz-Otto .
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 :486-493
[2]   Probe ablation for renal tumors: Comparison of cryoablation and radiofrequency ablation [J].
Hegarty, NJ ;
Kaouk, JH ;
Remer, E ;
O'Malley, CM ;
Desai, MM ;
Gill, LS ;
Novick, AC .
JOURNAL OF UROLOGY, 2006, 175 (04) :26-26
[3]   Optimization of an Endoscopic Radiofrequency Ablation Electrode [J].
Hanks, Bradley ;
Frecker, Mary ;
Moyer, Matthew .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2018, 12 (03)
[4]   Ablation of Bull Prostate Using Novel Bipolar Radiofrequency Ablation Probe [J].
Richstone, Lee ;
Ziegelbaum, Matt ;
Okeke, Zeph ;
Faure, Andre ;
Kaye, Jonathan D. ;
Sette, Marcelo J. ;
Reggio, Ernesto ;
Ost, Michael ;
Kavoussi, Louis R. ;
Lee, Benjamin R. .
JOURNAL OF ENDOUROLOGY, 2009, 23 (01) :11-16
[5]   Optimizing needle placement in treatment planning of radiofrequency ablation [J].
Chen, Chun-Cheng R. ;
Miga, Michael I. ;
Galloway, Robert L. .
MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
[6]   Support adapter for radiofrequency ablation probe: Experimental study [J].
Ishikawa, S ;
Oki, S ;
Muraoka, M ;
Kashiwabara, K ;
Morishita, Y .
ANZ JOURNAL OF SURGERY, 2005, 75 (03) :157-159
[7]   Radiofrequency tumor ablation system with a wireless or implantable probe [J].
Moore, Julian ;
Xu, Sheng ;
Wood, Bradford J. ;
Ren, Hongliang ;
Tse, Zion Tsz Ho .
WIRELESS POWER TRANSFER, 2020, 7 (02) :95-105
[8]   Ablation of bull prostates using novel bipolar radiofrequency ablation (RFA) probe [J].
Kaye, Jonathan ;
Richstone ;
Okeke, Zeph ;
Reggio, Ernesto ;
Ziegelbaum, Matt ;
Ost, Michael ;
Kavoussi, Louis ;
Lee, Benjamin .
JOURNAL OF ENDOUROLOGY, 2007, 21 :A100-A101
[9]   Effects of Needle Placement Inaccuracies in Hepatic Radiofrequency Tumor Ablation [J].
Khlebnikov, Rostislav ;
Muehl, Judith .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :716-721
[10]   Layout Optimization of Electrodes for Radiofrequency Ablation Instrument [J].
Grepl, J. ;
Penhaker, M. ;
Hlavackova, M. ;
Vavra, P. ;
Prokop, L. ;
Sikora, T. ;
Horyl, P. .
IEEE 11TH INTERNATIONAL SYMPOSIUM ON APPLIED MACHINE INTELLIGENCE AND INFORMATICS (SAMI 2013), 2013, :165-168