Non-invasive in vivo assessment of changes in peripheral arterial properties with estimation of arterial volume compliance

被引:13
作者
Zheng, Dingchang [1 ]
Allen, John [1 ]
Murray, Alan [1 ]
机构
[1] Univ Newcastle Upon Tyne, Freeman Hosp, Dept Med Phys, Cardiovas Phys & Engn Res Grp, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
关键词
arterial compliance; ectopic beat; photoplethysmography (PPG); pre-ejection time; pulse propagation time;
D O I
10.1088/0967-3334/28/10/015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arterial volume compliance reduces with age and with arterial disease and its easy non-invasive measurement will be of significant clinical value in monitoring the development of cardiovascular disease or evaluating therapy. However, the relationship between arterial volume compliance and pressure is not fully understood. To enable us to examine changing arterial characteristics, we studied the effect of naturally occurring pressure change, and in this pilot study investigated the effect of ectopic beats. Twenty-five subjects were studied. The electrocardiogram and the peripheral pulses, detected optically at the right ear and right finger, were recorded for subsequent analysis. The difference in pulse transit times between the finger and ear allowed the arm pulse propagation time to be determined, as the effect of ventricular ejection time was common to both measurements and hence removed. Finally, the relative arterial volume compliance changes were estimated based on the Moens-Korteweg equation. The arm pulse propagation time for sinus beats was 58 +/- 11 ms (mean +/- SD). Ectopic beats induced a significant increase of 7.2 +/- 6.9 ms (p < 0.001), those ectopic beats with short coupling intervals to the previous sinus beats a significant increase of 11.4 +/- 10.2 ms (p < 0.001) and post-ectopic sinus beats a significant fall of 3.4 +/- 4.6 ms (p = 0.001), all relative to the initial sinus beats. Ectopic beats induced a mean 14% increase in the arm pulse propagation time, equivalent to a 31% increase in relative arterial volume compliance. In conclusion, we have demonstrated that dynamic changes in arterial characteristics can be detected at a beat-to-beat level by the measurement of the arm pulse propagation time.
引用
收藏
页码:1317 / 1327
页数:11
相关论文
共 33 条
[1]   Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics [J].
Allen, J ;
Oates, CP ;
Lees, TA ;
Murray, A .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :811-821
[2]   Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes [J].
Allen, J ;
Murray, A .
JOURNAL OF HUMAN HYPERTENSION, 2002, 16 (10) :711-717
[3]   Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes [J].
Allen, J ;
Murray, A .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (06) :403-407
[4]  
AMETT DK, 2000, AM J HYPERTENS, V13, P317
[5]   ASSESSMENT OF ARTERIAL DISTENSIBILITY BY AUTOMATIC PULSE-WAVE VELOCITY-MEASUREMENT - VALIDATION AND CLINICAL-APPLICATION STUDIES [J].
ASMAR, R ;
BENETOS, A ;
TOPOUCHIAN, J ;
LAURENT, P ;
PANNIER, B ;
BRISAC, AM ;
TARGET, R ;
LEVY, BI .
HYPERTENSION, 1995, 26 (03) :485-490
[6]   Influence of age, risk factors, and cardiovascular and renal disease on arterial stiffness: Clinical applications [J].
Benetos, A ;
Waeber, B ;
Izzo, O ;
Mitchell, G ;
Resnick, L ;
Asmar, R ;
Safar, M .
AMERICAN JOURNAL OF HYPERTENSION, 2002, 15 (12) :1101-1108
[7]  
BENNETT DH, 1997, CARDIAC ARRHYTHMIAS
[8]   Relation of heart rate and blood pressure turbulence following premature ventricular complexes to baroreflex sensitivity in chronic congestive heart failure [J].
Davies, LC ;
Francis, DP ;
Ponikowski, P ;
Piepoli, MF ;
Coats, AJS .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (06) :737-742
[9]   Relation between heart rate and pulse transit time during paced respiration [J].
Drinnan, MJ ;
Allen, J ;
Murray, A .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (03) :425-432
[10]   Evaluation of blood pressure changes using vascular transit time [J].
Foo, Jong Yong Abdiel ;
Lim, Chu Sing ;
Wang, Ping .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (08) :685-694