Development of an HPLC/diode-array detector method for simultaneous determination of trigonelline, nicotinic acid, and caffeine in coffee

被引:31
|
作者
Casal, S [1 ]
Oliveira, MV [1 ]
Ferreira, MA [1 ]
机构
[1] Univ Porto, Fac Farm, CEQUP, Lab Bromatol, P-4050 Porto, Portugal
关键词
D O I
10.1080/10826079808001267
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an adequate procedure of reversed-phase HPLC/diode-array detector to be used in quality control to simultaneously quantify three nitrogen compounds: trigonelline, nicotinic acid, and caffeine, in coffee samples either in the green or roasted states. The chromatographic separation-was achieved using a reversed-phase column (Spherisorb ODS2) with gradient elution of 0.01M phosphate buffer pH 4.0 (A) and methanol (B). The effluent was monitored by a diode-array detector and the chromatograms were recorded at 265 nm. The sample preparation was quite simple involving only boiling water extraction and filtration. A linear relationship was found between peak area and concentration range of 0.15-450 mu g/mL, 0.10-500 mu g/mL, and 0.05-500 mu g/mL for trigonelline (at 268 nm), nicotinic acid (at 264 nm), and caffeine (at 276 nm), respectively. Extensive quality assurance of the proposed method was performed by the standard addition method in both green and roasted coffee. The precision in green coffee samples was better than 1.3, 5.8, and 1.1% and for roasted coffee, better than 0.5, 2.4, and 1.2% for trigonelline, nicotinic acid, and caffeine, respectively. Also, for green coffee, the mean recovery values were 98 +/- 1%, 84 +/- 5%, and 99 +/- 1% and for roasted coffee, these were 101 +/- 1%, 98 +/- 1%, and 99 +/- 1% for trigonelline, nicotinic acid, and caffeine, respectively. The proposed method appears to be an adequate method for quality control in the coffee industry.
引用
收藏
页码:3187 / 3195
页数:9
相关论文
共 50 条
  • [31] Simultaneous Determination of Trigonelline, Caffeine, Chlorogenic Acid and Their Related Compounds in Instant Coffee Samples by HPLC Using an Acidic Mobile Phase Containing Octanesulfonate
    Arai, Kana
    Terashima, Hiroyuki
    Aizawa, Sen-ichi
    Taga, Atsushi
    Yamamoto, Atsushi
    Tsutsumiuchi, Kaname
    Kodama, Shuji
    ANALYTICAL SCIENCES, 2015, 31 (08) : 831 - 835
  • [32] MULTIRESIDUE ANALYSIS OF PHENYLUREA HERBICIDES IN CROPS BY HPLC WITH DIODE-ARRAY DETECTOR
    LAGANA, A
    MARINO, A
    FAGO, G
    MARTINEZ, BP
    ANALUSIS, 1994, 22 (02) : 63 - 69
  • [33] Determination of alkyl methylphosphonates and methylphosphonic acid by capillary electrophoresis with a diode-array spectrophotometric detector
    Aleksenko, S. S.
    Tret'yakova, S. V.
    Mandych, V. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (04) : 421 - 424
  • [34] Determination of alkyl methylphosphonates and methylphosphonic acid by capillary electrophoresis with a diode-array spectrophotometric detector
    S. S. Aleksenko
    S. V. Tret’yakova
    V. G. Mandych
    Journal of Analytical Chemistry, 2011, 66
  • [35] Determination of gatifloxacin in semen by HPLC with diode-array and fluorescence detection
    Salazar-Cavazos, M. L.
    Gonzalez, L. Y. Colunga
    de Lerma, G. Gallegos
    de Torres, N. Waksman
    CHROMATOGRAPHIA, 2006, 63 (11-12) : 605 - 608
  • [36] Determination of Gatifloxacin in Semen by HPLC with Diode-Array and Fluorescence Detection
    M. L. Salazar Cavazos
    L. Y. Colunga González
    G. Gallegos de Lerma
    N. Waksman de Torres
    Chromatographia, 2006, 63 : 605 - 608
  • [37] Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection
    Pavlovic, Dragana Mutavdzic
    Asperger, Danijela
    Tolic, Dijana
    Babic, Sandra
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (18) : 3042 - 3049
  • [38] Determination of furosine in hydrolyzate of processed milk by HPLC using a narrow bore column and diode-array detector
    Nicoletti, I
    Cogliandro, E
    Corradini, C
    Corradini, D
    Pizzoferrato, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (05) : 717 - 726
  • [39] POTENTIALS OF HPLC WITH A MULTICHANNEL DIODE-ARRAY SPECTROPHOTOMETRIC DETECTOR IN SYSTEMATIC TOXICOLOGICAL ANALYSIS
    DEZEEUW, RA
    FRANKE, JP
    BOGUSZ, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 76 - ANYL
  • [40] Rapid and sensitive HPLC method for the simultaneous determination of dorzolamide hydrochloride and timolol maleate in eye drops with diode-array and UV detection
    Erk, N
    PHARMAZIE, 2003, 58 (07): : 491 - 493