Development of an HPLC/diode-array detector method for simultaneous determination of trigonelline, nicotinic acid, and caffeine in coffee

被引:31
|
作者
Casal, S [1 ]
Oliveira, MV [1 ]
Ferreira, MA [1 ]
机构
[1] Univ Porto, Fac Farm, CEQUP, Lab Bromatol, P-4050 Porto, Portugal
关键词
D O I
10.1080/10826079808001267
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an adequate procedure of reversed-phase HPLC/diode-array detector to be used in quality control to simultaneously quantify three nitrogen compounds: trigonelline, nicotinic acid, and caffeine, in coffee samples either in the green or roasted states. The chromatographic separation-was achieved using a reversed-phase column (Spherisorb ODS2) with gradient elution of 0.01M phosphate buffer pH 4.0 (A) and methanol (B). The effluent was monitored by a diode-array detector and the chromatograms were recorded at 265 nm. The sample preparation was quite simple involving only boiling water extraction and filtration. A linear relationship was found between peak area and concentration range of 0.15-450 mu g/mL, 0.10-500 mu g/mL, and 0.05-500 mu g/mL for trigonelline (at 268 nm), nicotinic acid (at 264 nm), and caffeine (at 276 nm), respectively. Extensive quality assurance of the proposed method was performed by the standard addition method in both green and roasted coffee. The precision in green coffee samples was better than 1.3, 5.8, and 1.1% and for roasted coffee, better than 0.5, 2.4, and 1.2% for trigonelline, nicotinic acid, and caffeine, respectively. Also, for green coffee, the mean recovery values were 98 +/- 1%, 84 +/- 5%, and 99 +/- 1% and for roasted coffee, these were 101 +/- 1%, 98 +/- 1%, and 99 +/- 1% for trigonelline, nicotinic acid, and caffeine, respectively. The proposed method appears to be an adequate method for quality control in the coffee industry.
引用
收藏
页码:3187 / 3195
页数:9
相关论文
共 50 条
  • [21] Determination of organophosphorus pesticides in biological samples of acute poisoning by HPLC with diode-array detector
    Cho, Y
    Matsuoka, N
    Kamiya, A
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1997, 45 (04) : 737 - 740
  • [22] Effective separation and simultaneous determination of seven fluoroquinolones by capillary electrophoresis with diode-array detector
    Sun, Han-wen
    He, Pan
    Lv, Yun-kai
    Liang, Shu-xuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 145 - 151
  • [23] HPLC with diode-array detection for determination of leflunomide in tablets
    Miron, DS
    Soldattelli, C
    Schapoval, EES
    CHROMATOGRAPHIA, 2006, 63 (5-6) : 283 - 287
  • [24] HPLC with Diode-Array Detection for Determination of Leflunomide in Tablets
    D. S. Miron
    C. Soldattelli
    E. E. S. Schapoval
    Chromatographia, 2006, 63 : 283 - 287
  • [25] MEASUREMENT OF CAFFEINE METABOLITES IN URINE USING DIODE-ARRAY DETECTION HPLC
    MICELI, JN
    CHAPMAN, W
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (11): : 2239 - 2251
  • [26] Development of an HPLC diode array detector method for the determination of human plasma adenosine concentrations
    Guieu, R
    Sampieri, F
    Bechis, G
    Halimi, G
    Dussol, B
    Berland, Y
    Sampol, J
    Rochat, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (12) : 1829 - 1841
  • [27] QuEChERS sample preparation in the simultaneous determination of residual amounts of quinolones, sulfanilamides, and amphenicols in food using HPLC with a diode-array detector
    V. G. Amelin
    N. M. Volkova
    A. A. Timofeev
    A. V. Tret’yakov
    Journal of Analytical Chemistry, 2015, 70 : 1076 - 1084
  • [28] QuEChERS Sample Preparation in the Simultaneous Determination of Residual Amounts of Quinolones, Sulfanilamides, and Amphenicols in Food Using HPLC with a Diode-Array Detector
    Amelin, V. G.
    Volkova, N. M.
    Timofeev, A. A.
    Tret'yakov, A. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (09) : 1076 - 1084
  • [29] DETERMINATION OF FURAZOLIDONE RESIDUES IN EGGS BY HPLC FOLLOWED BY CONFIRMATION WITH A DIODE-ARRAY UV VIS DETECTOR
    BEEK, WMJ
    AERTS, MML
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1985, 180 (03): : 211 - 214
  • [30] Simultaneous Determination of Trigonelline, Caffeine, Chlorogenic Acid and Their Related Compounds in Instant Coffee Samples by HPLC Using an Acidic Mobile Phase Containing Octanesulfonate
    Kana Arai
    Hiroyuki Terashima
    Sen-ichi Aizawa
    Atsushi Taga
    Atsushi Yamamoto
    Kaname Tsutsumiuchi
    Shuji Kodama
    Analytical Sciences, 2015, 31 : 831 - 835