The vaccination threshold for SARS-CoV-2 depends on the indoor setting and room ventilation

被引:13
作者
Mikszewski, A. [1 ,2 ]
Stabile, L. [3 ]
Buonanno, G. [1 ,3 ]
Morawska, L. [1 ,4 ]
机构
[1] Queensland Univ Technol, Int Lab Air Qual & Hlth, 2 George St, Brisbane, Qld 4001, Australia
[2] CUNY, CIUS Bldg Performance Lab, New York, NY 10001 USA
[3] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Cassino, FR, Italy
[4] Univ Surrey, Global Ctr Clean Air Res GCARE, Dept Civil & Environm Engn, Fac Engn & Phys Sci, Guildford GU2 7XH, Surrey, England
关键词
SARS-CoV-2; Airborne transmission; Ventilation; Vaccination; DISTEMPER; DISEASE; SPREAD; RISK; AIR;
D O I
10.1186/s12879-021-06884-0
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Effective vaccines are now available for SARS-CoV-2 in the 2nd year of the COVID-19 pandemic, but there remains significant uncertainty surrounding the necessary vaccination rate to safely lift occupancy controls in public buildings and return to pre-pandemic norms. The aim of this paper is to estimate setting-specific vaccination thresholds for SARS-CoV-2 to prevent sustained community transmission using classical principles of airborne contagion modeling. We calculated the airborne infection risk in three settings, a classroom, prison cell block, and restaurant, at typical ventilation rates, and then the expected number of infections resulting from this risk at varying percentages of occupant immunity. Results We estimate the setting-specific immunity threshold for control of wild-type SARS-CoV-2 to range from a low of 40% for a mechanically ventilation classroom to a high of 85% for a naturally ventilated restaurant. Conclusions If vaccination rates are limited to a theoretical minimum of approximately two-thirds of the population, enhanced ventilation above minimum standards for acceptable air quality is needed to reduce the frequency and severity of SARS-CoV-2 superspreading events in high-risk indoor environments.
引用
收藏
页数:9
相关论文
共 43 条
[1]   Clustering and superspreading potential of SARS-CoV-2 infections in Hong Kong [J].
Adam, Dillon C. ;
Wu, Peng ;
Wong, Jessica Y. ;
Lau, Eric H. Y. ;
Tsang, Tim K. ;
Cauchemez, Simon ;
Leung, Gabriel M. ;
Cowling, Benjamin J. .
NATURE MEDICINE, 2020, 26 (11) :1714-+
[2]  
American Society of Heating Refrigerating and Air-Conditioning Engineers Inc. (ASHRAE), 2019, 6212019 ANSIASHRAE, P92
[3]  
ANDERSON R M, 1991
[4]  
[Anonymous], 2007, 152512007 INDOOR ENV
[5]   Aerosol emission and superemission during human speech increase with voice loudness [J].
Asadi, Sima ;
Wexler, Anthony S. ;
Cappa, Christopher D. ;
Barreda, Santiago ;
Bouvier, Nicole M. ;
Ristenpart, William D. .
SCIENTIFIC REPORTS, 2019, 9 (1)
[6]   Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications [J].
Buonanno, G. ;
Morawska, L. ;
Stabile, L. .
ENVIRONMENT INTERNATIONAL, 2020, 145
[7]  
California Department of Corrections and Rehabilitation, POP COVID 19 TRACK
[8]   Mobility network models of COVID-19 explain inequities and inform reopening [J].
Chang, Serina ;
Pierson, Emma ;
Koh, Pang Wei ;
Gerardin, Jaline ;
Redbird, Beth ;
Grusky, David ;
Leskovec, Jure .
NATURE, 2021, 589 (7840) :82-U54
[9]   Assessment of the impact of particulate dry deposition on soiling of indoor cultural heritage objects found in churches and museums/libraries [J].
Chatoutsidou, Sofia Eirini ;
Lazaridis, Mihalis .
JOURNAL OF CULTURAL HERITAGE, 2019, 39 :221-228
[10]   Heterogeneity in transmissibility and shedding SARS-CoV-2 via droplets and aerosols [J].
Chen, Paul Z. ;
Bobrovitz, Niklas ;
Premji, Zahra ;
Koopmans, Marion ;
Fisman, David N. ;
Gu, Frank X. .
ELIFE, 2021, 10