Temporal pulsed x-ray response of CdZnTe: In detector

被引:3
|
作者
Guo, Rong-Rong [1 ,2 ]
Xu, Ya-Dong [2 ]
Zha, Gang-Qiang [2 ]
Wang, Tao [2 ]
Jie, Wan-Qi [2 ]
机构
[1] Xiamen Univ Technol, Sch Optoelect & Commun Engn, Xiamen 361024, Peoples R China
[2] Northwestern Polytech Univ, State Key Lab Solidificat Proc, Xian 710072, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
CdZnTe; ultrafast-pulsed x-rays; transient current; charge carrier; CDTE; PERFORMANCE; TELLURIDE;
D O I
10.1088/1674-1056/27/12/127202
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The temporal response of cadmium-zinc-telluride (CZT) crystals is evaluated at room temperature by using an ultrafast-pulsed x-ray source. The dynamics of carrier relaxation in a CZT single crystal is modeled at a microscopic level based on a multi-trapping effect. The effects of the irradiation flux and bias voltage on the amplitude and full width at half maximum (FWHM) of the transient currents are investigated. It is demonstrated that the temporal response process is affected by defect level occupation fraction. A fast photon current can be achieved under intense pulsed x-ray irradiation to be up to 2.78x10(9) photons mm(-2) s(-1). Meanwhile, it is found that high bias voltage could enhance carrier detrapping by suppressing the capture of structure defects and thus improve the temporal response of CZT detectors.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Some diagnostic X-ray spectra and exposure measured using CdZnTe detector
    Matsumoto, M
    Miyajima, S
    Yamamoto, A
    Yamazaki, T
    Kubota, H
    Kanamori, H
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2513 - 2516
  • [22] Linear X-ray detector array made on bulk CdZnTe for 30 similar to 100 keV energy
    Yoo, SS
    Jennings, G
    Montano, PA
    JOURNAL OF ELECTRONIC MATERIALS, 1997, 26 (06) : 750 - 755
  • [23] Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator
    Park, Beomjun
    Ko, Juyoung
    Byun, Jangwon
    Park, Byungdo
    Lee, Man-Jong
    Kim, Jeongho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (08) : 2797 - 2801
  • [24] γ-ray energy spectrum response tailing in CdZnTe detector
    Li, Linxiang
    Huang, Guangwei
    Xi, Shanxue
    Zhang, Siyuan
    Zhou, Chunzhi
    Liu, Dahai
    Wang, Zungang
    Zeng, Guoqiang
    Yang, Xiaofeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1037
  • [25] Schottky-type polycrystalline CdZnTe X-ray detectors
    Kim, KiHyun
    Cho, ShinHang
    Suh, JongHee
    Won, JaeHo
    Hong, JinKi
    Kim, SunUng
    CURRENT APPLIED PHYSICS, 2009, 9 (02) : 306 - 310
  • [26] The effect of low energy high-dose X-ray irradiation on the performance of CdZnTe detector
    Liu, Hongguang
    Yu, Haiwen
    Jia, Ningbo
    Chen, Jianquan
    Yang, Mei
    Sun, Zhengyi
    Yu, Gang
    Li, Yudong
    Xi, Shouzhi
    Yang, Fan
    Wang, Tao
    Jie, Wanqi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1071
  • [27] Control of the interface shape in vertical Bridgman grown CdZnTe crystals for X-ray detector applications
    Zappettini, Andrea
    Zha, Mingzheng
    Marchini, Laura
    Calestani, Davide
    CRYSTENGCOMM, 2012, 14 (18): : 5992 - 5995
  • [28] Boron Oxide Encapsulated Vertical Bridgman Grown CdZnTe Crystals as X-ray Detector Material
    Zappettini, Andrea
    Zha, Mingzheng
    Marchini, Laura
    Calestani, Davide
    Mosca, Roberto
    Gombia, Enos
    Zanotti, Lucio
    Zanichelli, Massimiliano
    Pavesi, Maura
    Auricchio, Natalia
    Caroli, Ezio
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4925 - +
  • [29] Hard x-ray response of CdZnTe detectors in the swift burst alert telescope
    Suzuki, M
    Tashiro, M
    Sato, G
    Watanabe, S
    Nakazawa, K
    Takahashi, T
    Okada, Y
    Takahashi, H
    Parsons, A
    Barthelmy, S
    Cummings, J
    Gehrels, N
    Hullinger, D
    Krimm, H
    Tueller, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1033 - 1035
  • [30] Hard X-ray response of CdZnTe detectors in the swift burst alert telescope
    Suzuki, M
    Tashiro, M
    Sato, G
    Watanabe, S
    Takahashi, T
    Okada, Y
    Takahashi, F
    Parsons, A
    Barthelmy, S
    Cummings, J
    Gehrels, N
    Hullinger, D
    Krimm, HF
    Tueller, J
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3550 - 3554