Electrical performance and radiation sensitivity of stacked PMOS dosimeters under bulkbias control

被引:26
作者
O'Connell, B [1 ]
Conneely, C
Mc Carthy, C
Doyle, J
Lane, W
Adams, L
机构
[1] Natl Univ Ireland Univ Coll Cork, NMRC, Cork, Ireland
[2] European Space Agcy, ESTEC, Noordwijk, Netherlands
关键词
D O I
10.1109/23.736516
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new method for biasing stacked PMOS dosimeters has shown the potential for increased radiation dose range. This method involves control of the output voltage of stacked depletion mode RADFETs by an appropriate bulkbias. Radiation sensitivity measurement has shown impressive results where 84mV/rad sensitivity has been demonstrated. The possibility of a Zero Temperature Coefficient (ZTC) bulkbias may also prove attractive. Simulation and measurement are in close agreement indicating that proposed device geometry changes should further reduce the output voltage while maintaining milli-rad radiation sensitivity capability. Simulation shows that radiation sensitivity of up to 120mV/rad can be achieved with proposed Width/Length (W/L) device geometry changes.
引用
收藏
页码:2689 / 2694
页数:6
相关论文
共 9 条
[1]  
CONNEELY C, 1997, THESIS NATL U IRELAN
[2]  
CONNEELY C, 1997, C P RADESCS97 CANN
[3]   SPACE-CHARGE DOSIMETER - GENERAL PRINCIPLES OF A NEW METHOD OF RADIATION DETECTION [J].
HOLMESSI.A .
NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01) :169-179
[4]  
HOLMESSIEDLE A, 1986, RADIAT PHYS CHEM, V28, P235
[5]  
MCCARTHY C, 1998, THESIS NATL U IRELAN
[6]   Stacked RADFETs for increased radiation sensitivity. [J].
OConnell, B ;
Kelleher, A ;
Lane, W ;
Adams, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :985-990
[7]  
OCONNELL B, 1995, THESIS NATL U IRELAN
[8]  
RISTIC G, 1996, SENSOR ACTUAT A-PHYS, P51
[9]   ELECTRICAL-PROPERTIES OF MOS RADIATION DOSIMETERS [J].
SARRABAYROUSE, G ;
BELLAOUAR, A ;
ROSSEL, P .
REVUE DE PHYSIQUE APPLIQUEE, 1986, 21 (04) :283-287