Best surgical technique and outcomes for large macular holes: retrospective multicentre study in Japan

被引:62
作者
Yamashita, Toshifumi [1 ]
Sakamoto, Taiji [1 ]
Terasaki, Hiroto [1 ]
Iwasaki, Masanori [2 ]
Ogushi, Yoko [3 ]
Okamoto, Fumiki [4 ]
Takeuchi, Masaru [5 ]
Yasukawa, Tsutomu [6 ]
Takamura, Yoshihiro [7 ]
Ogata, Nahoko [8 ]
Nakamura, Yumiko [9 ]
机构
[1] Kagoshima Univ, Grad Sch Med & Dent Sci, Dept Ophthalmol, 8-35-1 Sakuragaoka, Kagoshima 8908520, Japan
[2] Sapporo City Gen Hosp, Dept Ophthalmol, Sapporo, Hokkaido, Japan
[3] Univ Tokushima, Grad Sch, Inst Hlth Biosci, Dept Ophthalmol, Tokushima, Japan
[4] Univ Tsukuba, Fac Med, Dept Ophthalmol, Tsukuba, Ibaraki, Japan
[5] Natl Def Med Coll, Dept Ophthalmol, Tokorozawa, Saitama, Japan
[6] Nagoya City Univ, Grad Sch Med Sci, Dept Ophthalmol & Visual Sci, Nagoya, Aichi, Japan
[7] Univ Fukui, Fac Med Sci, Dept Ophthalmol, Fukui, Japan
[8] Nara Med Univ, Dept Ophthalmol, Kashihara, Nara, Japan
[9] Hyogo Coll Med, Dept Ophthalmol, Nishinomiya, Hyogo, Japan
关键词
inverted ILM peeling; large macular hole; macular hole; vitrectomy; INTERNAL LIMITING MEMBRANE; OPTICAL COHERENCE TOMOGRAPHY; FLAP TECHNIQUE; FACE-DOWN; VITREOUS SURGERY; CLOSURE; CLASSIFICATION; DETACHMENT; VITRECTOMY; EFFICACY;
D O I
10.1111/aos.13795
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to compare the surgical outcomes of vitrectomy with conventional internal limiting membrane (C-ILM) peeling to that with the inverted ILM (I-ILM) flap technique for large macular holes (MHs). This was a retrospective chart review of consecutive cases with a large MH at nine hospitals in Japan. Among the 1342 eyes, 165 eyes of 165 cases met the inclusion criteria. The results for medium-large MHs with a diameter 400-550 mu m were compared to that of eyes with an extra-large MH with a diameter >550 mu m. In addition, the results of C-ILM peeling were compared to that of the I-ILM technique. In medium-large MHs, the closure rate was 95.2% (59/62) by C-ILM peeling and 100% (19/19) by the I-ILM technique. In extra-large MHs, the closure rate was 88.4% (38/43) by C-ILM peeling and 100% (41/41) by I-ILM. Although the difference between the two methods was not significant, the I-ILM technique was successful in 100% of the cases. Multiple logistic regression analysis showed the best-corrected visual acuity (BCVA) at 6 months was significantly associated with the preoperative BCVA, MH size, age and sex of the patient. Analyses of the eyes with extra-large MHs show that the surgical success is high, and the I-ILM technique is more effective for closure in eyes with extra-large MHs.
引用
收藏
页码:E904 / E910
页数:7
相关论文
共 37 条
[1]   EFFICACY OF THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE WITH VITRECTOMY FOR RETINAL DETACHMENT ASSOCIATED WITH MYOPIC MACULAR HOLES [J].
Baba, Ryo ;
Wakabayashi, Yoshihiro ;
Umazume, Kazuhiko ;
Ishikawa, Tomoaki ;
Yagi, Hiromichi ;
Muramatsu, Daisuke ;
Goto, Hiroshi .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (03) :466-471
[2]   Macular hole surgery with and without internal limiting membrane peeling [J].
Brooks, HL .
OPHTHALMOLOGY, 2000, 107 (10) :1939-1948
[3]   CLOSING MACULAR HOLES WITH "MACULAR PLUG" WITHOUT GAS TAMPONADE AND POSTOPERATIVE POSTURING [J].
Chakrabarti, Meena ;
Benjamin, Preethi ;
Chakrabarti, Keya ;
Chakrabarti, Arup .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (03) :451-459
[4]   Double Internal Limiting Membrane Insertion for Macular Hole-Associated Retinal Detachment [J].
Chen, San-Ni ;
Yang, Chung-May .
JOURNAL OF OPHTHALMOLOGY, 2017, 2017
[5]   Autologous Free Internal Limiting Membrane Flap for Optic Nerve Head Pit With Maculopathy [J].
D'Souza, Palmeera ;
Babu, Upendra ;
Narendran, Venkatapathy .
OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2017, 48 (04) :350-353
[6]  
Forsaa VA, ACTA OPHTHALMOL
[7]   REAPPRAISAL OF BIOMICROSCOPIC CLASSIFICATION OF STAGES OF DEVELOPMENT OF A MACULAR HOLE [J].
GASS, JDM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (06) :752-759
[8]   Pedicle Internal Limiting Membrane Transposition Flap Technique for Refractory Macular Hole [J].
Gekka, Tamaki ;
Watanabe, Akira ;
Ohkuma, Yasuhiro ;
Arai, Kota ;
Watanabe, Tomoyuki ;
Tsuzuki, Akane ;
Tsuneoka, Hiroshi .
OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (10) :1045-1046
[9]   Autologous Neurosensory Retinal Free Flap for Closure of Refractory Myopic Macular Holes [J].
Grewal, Dilraj S. ;
Mahmoud, Tamer H. .
JAMA OPHTHALMOLOGY, 2016, 134 (02) :229-230
[10]   Comparison of face-down and seated position after idiopathic macular hole surgery: A randomized clinical trial [J].
Guillaubey, Alexandre ;
Malvitte, Laure ;
Lafontaine, Pierre Olivier ;
Jay, Nicolas ;
Hubert, Isabelle ;
Bron, Alain ;
Berrod, Jean Paul ;
Creuzot-Garcher, Catherine .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (01) :128-134