Human responses to high air temperature, relative humidity and carbon dioxide concentration in underground refuge chamber

被引:56
作者
Li, Yong [1 ,3 ]
Yuan, Yanping [2 ]
Li, Chaofeng [1 ]
Han, Xu [1 ]
Zhang, Xiaosong [3 ]
机构
[1] Army Engn Univ PLA, Nanjing 210007, Jiangsu, Peoples R China
[2] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Sichuan, Peoples R China
[3] Southeast Univ, Nanjing 210007, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Underground refuge chamber; Human response; CO2; concentration; High relative humidity; CO2; CONCENTRATION; THERMAL COMFORT; HOT; ENVIRONMENT; EXPOSURE; QUALITY; INTENSITY; IMPACT; LIMITS; MALLS;
D O I
10.1016/j.buildenv.2017.12.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In underground confined spaces with a crowded population, the thermal environment will be hot-humid and occurred with high CO2 concentration. Investigating the combined effect of increased temperature, relative humidity and CO2 concentration on human responses is important for confined spaces. In this paper, 32 subjects were exposed to different combinations of air temperature (TO, relative humidity (RH) and CO2 concentrations in an underground climate chamber, with thermal response, physiological response and acute health symptoms being investigated. Results show that: at a T-a of 28 degrees C, RH of 65% and CO2 level of 12,000 ppm, thermal sensation votes (TSV) and thermal acceptability (TA) did not significantly changed, while a significant change was recorded with a RH of 85%. When CO2 concentration increased to 8000 ppm, the subjects' perceived air quality acceptability significantly decreased at T-a of 33 degrees C, however it did not significantly change at T-a of 28 degrees C and RH of 65%. Maximum mean skin temperature and wetness difference did not exceed 0.3 degrees C and 0.15 units between the different exposure conditions, respectively. Significant changes of headaches were observed when CO2 concentrations increased to 12,000 ppm at a RH of 85%, but the difference was not statistically significant at a RH of 65%. This indicated that the combined effects of high T-a, RH and CO2 concentration lead to different human responses.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 57 条
  • [1] Impact of ventilation modes on carbon dioxide concentration levels in Kuwait classrooms
    Al-Rashidi, Khaled
    Loveday, Dennis
    Al-Mutawa, Nawaf
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 540 - 549
  • [2] Flavoring Chemicals in E-Cigarettes: Diacetyl, 2,3-Pentanedione, and Acetoin in a Sample of 51 Products, Including Fruit-, Candy-, and Cocktail-Flavored E-Cigarettes
    Allen, Joseph G.
    Flanigan, Skye S.
    LeBlanc, Mallory
    Vallarino, Jose
    MacNaughton, Piers
    Stewart, James H.
    Christiani, David C.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) : 733 - 739
  • [3] Underground railway environment in the UK Part 1: Review of thermal comfort
    Ampofo, F
    Maidment, G
    Missenden, J
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (5-6) : 611 - 631
  • [4] [Anonymous], 2005, 5003852005 GB MIN HO
  • [5] [Anonymous], 2000, PREVENTING MANAGING, P1, DOI [10.1007/BF02986808, DOI 10.1007/BF02986808]
  • [6] [Anonymous], 2009, GEN TECHN REQ MOB RE
  • [7] ASHRAE, 1992, 551992 ASHRAE
  • [8] ASHRAE SI, 2009, ASHRAE HDB FUND
  • [9] Association Advancing Occupational and Environmental Health (ACGIH), 1999, THRESH LIM VAL CHEM
  • [10] Ventilation rates in schools and pupils' performance
    Bako-Biro, Zs.
    Clements-Croome, D. J.
    Kochhar, N.
    Awbi, H. B.
    Williams, M. J.
    [J]. BUILDING AND ENVIRONMENT, 2012, 48 : 215 - 223