High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results

被引:77
作者
Gimelli, Alessia [2 ]
Bottai, Matteo [1 ,3 ,4 ]
Genovesi, Dario [2 ]
Giorgetti, Assuero [2 ]
Di Martino, Fabio [5 ]
Marzullo, Paolo [2 ]
机构
[1] Univ S Carolina, Div Biostatist, Columbia, SC USA
[2] CNR, Fdn Toscana Gabriele Monasterio, I-56124 Pisa, Italy
[3] Univ S Carolina, Div Biostat, Columbia, SC 29208 USA
[4] Karolinska Inst, Div Biostat, Stockholm, Sweden
[5] AOUP, UO Fis Sanit, Pisa, Italy
关键词
Low-dose ultrafast SPECT; Coronary artery disease; Stress-rest myocardial imaging; MYOCARDIAL-PERFUSION SPECT; ASSOCIATION TASK-FORCE; HEART-ASSOCIATION; CORONARY-ANGIOGRAPHY; PRACTICE GUIDELINES; AMERICAN-COLLEGE; STABLE ANGINA; MANAGEMENT; COMMITTEE; DISEASE;
D O I
10.1007/s00259-011-1918-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Appropriate use of SPECT imaging is regulated by evidence-based guidelines and appropriateness criteria in an effort to limit the burden of radiation administered to patients. We aimed at establishing whether the use of a low dose for stress-rest single-day nuclear myocardial perfusion imaging on an ultrafast (UF) cardiac gamma camera using cadmium-zinc-telluride solid-state detectors could be used routinely with the same accuracy obtained with standard doses and conventional cameras. Methods To this purpose, 137 consecutive patients (mean age 61 +/- 8 years) with known or suspected coronary artery disease (CAD) were enrolled. They underwent single-day low-dose stress-rest myocardial perfusion imaging using UF SPECT and invasive coronary angiography. Patients underwent the first scan with a 7-min acquisition time 10 min after the end of the stress protocol (dose range 185 to 222 MBq of Tc-99m-tetrofosmin). The rest scan (dose range 370 to 444 MBq of Tc-99m-tetrofosmin) was acquired with a 6-min acquisition time. The mean summed stress scores (SSS) and mean summed rest scores (SRS) were obtained semiquantitatively. Results Coronary angiograms showed significant epicardial CAD in 83% of patients. Mean SSS and SRS were 10 +/- 5 and 3 +/- 3, respectively. Overall the area under the ROC curve for the SSS values was 0.904, while the areas under the ROC curves for each vascular territory were 0.982 for the left anterior descending artery, 0.931 for the left circumflex artery and 0.889 for the right coronary artery. Conclusion This pilot study demonstrated the feasibility of a low-dose single-day stress-rest fasting protocol performed using UF SPECT, with good sensitivity and specificity in detecting CAD at low patient exposure, opening new perspectives in the use of myocardial perfusion in ischaemic patients.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 25 条
[1]   Stress Thallium-201/Rest Technetium-99m Sequential Dual Isotope High-Speed Myocardial Perfusion Imaging [J].
Berman, Daniel S. ;
Kang, Xingping ;
Tamarappoo, Balaji ;
Wolak, Arik ;
Hayes, Sean W. ;
Nakazato, Ryo ;
Thomson, Louise E. J. ;
Kite, Faith ;
Cohen, Ishac ;
Slomka, Piotr J. ;
Einstein, Andrew J. ;
Friedman, John D. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) :273-282
[2]   Comparison of intravascular ultrasound and quantitative coronary angiography for the assessment of coronary artery disease progression [J].
Berry, Colin ;
L'Allier, Philippe L. ;
Gregoire, Jean ;
Lesperance, Jacques ;
Levesque, Sylvie ;
Ibrahim, Reda ;
Tardif, Jean-Claude .
CIRCULATION, 2007, 115 (14) :1851-1857
[3]   Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies [J].
Borges-Neto, Salvador ;
Pagnanelli, Robert A. ;
Shaw, Linda K. ;
Honeycutt, Emily ;
Shwartz, Shuli C. ;
Adams, George L. ;
Coleman, Ralph Edward .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :555-565
[4]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]   A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT [J].
DePuey, E. Gordon ;
Bommireddipalli, Srinivas ;
Clark, John ;
Leykekhman, Anna ;
Thompson, Linda B. ;
Friedman, Marvin .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (02) :273-280
[7]   Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera [J].
Duvall, W. Lane ;
Croft, Lori B. ;
Ginsberg, Eric S. ;
Einstein, Andrew J. ;
Guma, Krista A. ;
George, Titus ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) :847-857
[8]   Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera [J].
Duvall, W. Lane ;
Croft, Lori B. ;
Godiwala, Tapan ;
Ginsberg, Eric ;
George, Titus ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) :1009-1014
[9]   Radiation dose to patients from cardiac diagnostic imaging [J].
Einstein, Andrew J. ;
Moser, Kevin W. ;
Thompson, Randall C. ;
Cerqueira, Manuel D. ;
Henzlova, Milena J. .
CIRCULATION, 2007, 116 (11) :1290-1305
[10]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323