Integrating amperometric detection with electrophoresis microchip devices for biochemical assays: Recent developments

被引:38
作者
Ghanim, M. H. [1 ]
Abdullah, M. Z. [1 ]
机构
[1] Univ Sains Malaysia, Sch Elect & Elect Engn, Perai 14300, Pulau Pinang, Malaysia
关键词
Capillary electrophoresis; Lab-On-a-Chip; Electrochemistry; Amperometry; Microchip; Biosensors; POLY(DIMETHYLSILOXANE) MICROFLUIDIC CHANNELS; ELECTROCHEMICAL DETECTION; CAPILLARY-ELECTROPHORESIS; DNA ANALYSIS; CARBON NANOTUBE; AMINO-ACIDS; LABEL-FREE; CHIP; FABRICATION; ELECTRODE;
D O I
10.1016/j.talanta.2011.04.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent advances in microfluidic systems, particularly in the Micro Total Analysis System (mu TAS) or Lab On a Chip (LOC), drive the current analysis tools and equipment towards miniaturization, rapid at-line testing and mobility. The state-of-the-art microfluidic technology targets a wider range but smaller volumes of analytes, making the analytical procedure relatively easier and faster. This trend together with faster electronics and modern instrumentation systems will make real-time and in situ analysis a definite possibility. This review focuses on microchip capillary electrophoresis with amperometric detection (MCE-AD) for the detection of DNA and other electroactive analytes. The problems associated with the microchip design, in particular the choice of materials and the configuration of electrodes are discussed thoroughly and solutions are proposed. Significant developments in the related areas are also covered and reviewed critically. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 103 条
[11]  
2-I
[12]   Fabrication, modification, and application of department of analytical poly(methyl methacrylate) microfluidic chips [J].
Chen, Yun ;
Zhang, Luyan ;
Chen, Gang .
ELECTROPHORESIS, 2008, 29 (09) :1801-1814
[13]   Development of a bienzyme system based on sugar-lectin biospecific interactions for amperometric determination of phenols and aromatic amines [J].
Chen, Zhichun ;
Xi, Fengna ;
Yang, Shaoming ;
Wu, Qi ;
Lin, Xianfu .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (02) :900-907
[14]   Carbon nanotubes combined with inorganic nanomaterials: Preparations and applications [J].
Chu, Haibin ;
Wei, Li ;
Cui, Rongli ;
Wang, Jinyong ;
Li, Yan .
COORDINATION CHEMISTRY REVIEWS, 2010, 254 (9-10) :1117-1134
[15]   Rapid determination of acetaminophen and p-aminophenol in pharmaceutical formulations using miniaturized capillary electrophoresis with amperometric detection [J].
Chu, Qingcui ;
Jiang, Lianmei ;
An, Xiuhui ;
Ye, Jiannong .
ANALYTICA CHIMICA ACTA, 2008, 606 (02) :246-251
[16]   Separation of catecholamines and dopamine-derived DNA adduct using a microfluidic device with electrochemical detection [J].
Dawoud, A. A. ;
Kawaguchi, T. ;
Markushin, Y. ;
Porter, M. D. ;
Jankowiak, R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01) :42-50
[17]  
Dawoud AA, 2008, INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 11 PT A AND PT B: MICRO AND NANO SYSTEMS, P467
[18]   In-channel modification of electrochemical detector for the detection of bio-targets on microchip [J].
Dawoud, Abdulilah A. ;
Kawaguchi, Toshikazo ;
Jankowiak, Ryszard .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (07) :1536-1541
[19]   Integrated microfluidic device with an electroplated palladium decoupler for more sensitive amperometric detection of the 8-hydroxy-deoxyguanosine (8-OH-dG) DNA adduct [J].
Dawoud, Abdulilah A. ;
Kawaguchi, Toshikazo ;
Jankowiak, Ryszard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (01) :245-252
[20]   Electrochemistry of redox-active self-assembled monolayers [J].
Eckermann, Amanda L. ;
Feld, Daniel J. ;
Shaw, Justine A. ;
Meade, Thomas J. .
COORDINATION CHEMISTRY REVIEWS, 2010, 254 (15-16) :1769-1802