Label-free electrochemical detection for aptamer-based array electrodes

被引:268
|
作者
Xu, DK [1 ]
Xu, DW [1 ]
Yu, XB [1 ]
Liu, ZH [1 ]
He, W [1 ]
Ma, ZQ [1 ]
机构
[1] Beijing Inst Radiat Med, Dept Biochem, Beijing 100850, Peoples R China
关键词
D O I
10.1021/ac050192m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-mu L sample) was obtained, and an average of the relative standard deviation was < 10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.
引用
收藏
页码:5107 / 5113
页数:7
相关论文
共 50 条
  • [1] Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor
    Akbarzadeh, Sanaz
    Khajehsharifi, Habibollah
    Hajihosseini, Saeedeh
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [2] Label-free detection of kanamycin using aptamer-based cantilever array sensor
    Bai, Xiaojing
    Hou, Hui
    Zhang, Bailin
    Tang, Jilin
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 112 - 116
  • [3] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385
  • [4] Aptamer-Based Electrochemical Sensor for Label-Free Recognition and Detection of Cancer Cells
    Pan, Chunfeng
    Guo, Manli
    Nie, Zhou
    Xiao, Xilin
    Yao, Shouzhuo
    ELECTROANALYSIS, 2009, 21 (11) : 1321 - 1326
  • [5] Aptamer-based biosensor for label-free detection of ethanolamine by electrochemical impedance spectroscopy
    Liang, Gang
    Man, Yan
    Jin, Xinxin
    Pan, Ligang
    Liu, Xinhui
    ANALYTICA CHIMICA ACTA, 2016, 936 : 222 - 228
  • [6] A Label-Free Electrochemical Detection of Cadmium Ions Using Aptamer-Based Biosensor
    Zaras, Izabela
    Kralka, Ewa
    Olszewski, Marcin
    Jarczewska, Marta
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (11)
  • [7] Ultrasensitive label-free aptamer-based electronic detection
    Xiang, Yun
    Xie, Mingyi
    Bash, Ralph
    Chen, Julian J. L.
    Wang, Joseph
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (47) : 9054 - 9056
  • [8] Label-free aptamer-based chemiluminescence detection of adenosine
    Yan, Xiluan
    Cao, Zhijuan
    Kai, Masaaki
    Lu, Jianzhong
    TALANTA, 2009, 79 (02) : 383 - 387
  • [9] Aptamer-Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
    Eissa, Shimaa
    Zourob, Mohammed
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Aptamer-based biosensors for label-free voltammetric detection of lysozyme
    Cheng, Alan K. H.
    Ge, Bixia
    Yu, Hua-Zhong
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5158 - 5164