Dosimetric evaluation for temporomandibular joint cone beam computed tomography exams using different field of view

被引:0
作者
Pinto, Carla Alves [1 ]
Caetano, Gabriela Franco da Rosa [1 ]
Andrade, Marcos Ely Almeida [2 ]
Panzarella, Francine Kull [1 ]
Junqueira, Jose Luiz Cintra [1 ]
Peroni, Leonardo Vieira [3 ]
Nascimento, Monikelly do Carmo Chagas [1 ]
机构
[1] Inst Pesquisas Sao Leopoldo Mand, Fac Sao Leopoldo Mand, Div Oral Radiol, BR-13045755 Campinas, SP, Brazil
[2] Univ Tiradentes, Dept Radiol, BR-13045755 Recife, PE, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, BR-13045755 Piracicaba, SP, Brazil
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2021年 / 7卷 / 06期
关键词
temporomandibular joint; thermoluminescent dosimetry; cone beam computed tomography; radiation dosage; radiation exposure; IMAGE QUALITY; CT; SIZE;
D O I
10.1088/2057-1976/ac240a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives. To optimize the absorbed organ dose in relation to the field of view for temporomandibular joint examinations in four cone beam computed tomography devices. Methods. An anthropomorphic adult head and neck phantom, and 192 LiF dosimeters (TLD-100) were used. The dosimeters were placed in the region corresponding to the lens, parotid glands, submandibular glands, and thyroid. Small, medium and large FOVs were selected on Orthopantomograph OP300 Maxio, PaX-i3D Smart, ORTHOPHOS XG, and i-CAT Next Generation device when it was possible. Results. A wide range of absorbed dose values was recorded for all organs due to the different exposure parameters of each device. The radiosensitive organ with the highest dose was the parotid glands. The devices with 5 x 5 cm FOV recorded a lower dose in this protocol, while for the device without a small FOV (<= 5 x 5 cm), the lowest dose was observed with the large FOV (6 x 16 cm). Conclusions. We recommend a double exposure with an FOV of 5 x 5 cm in the OP300 Maxio, PaX-i3D Smart, and ORTHOPHOS XG device, while in the i-CAT Next Generation device, a single exposure FOV of 6 x 16 cm is indicated.
引用
收藏
页数:6
相关论文
共 31 条
  • [1] Measurement of skin dose from cone-beam computed tomography imaging
    Akyalcin, Sercan
    English, Jeryl D.
    Abramovitch, Kenneth M.
    Rong, Xiujiang J.
    [J]. HEAD & FACE MEDICINE, 2013, 9
  • [2] DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY
    Andrade, Marcos E. A.
    Khoury, Helen J.
    Nascimento Neto, Joao B. S.
    Kramer, Richard
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 175 - 180
  • [3] [Anonymous], 2011, Statement on tissue reactions
  • [4] Image quality optimization of narrow detector dental computed tomography for paediatric patients
    Brasil, Danieli Moura
    Pauwels, Ruben
    Coucke, Wim
    Haiter-Neto, Francisco
    Jacobs, Reinhilde
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (05)
  • [5] Bushberg JT, 2014, P 15 ANN M PROGR NCR, P5
  • [6] Cordeiro Patrícia C. F, 2016, Acta odontol. latinoam., V29, P219
  • [7] Objective and subjective image evaluation of maxillary alveolar bone based on cone beam computed tomography exposure parameters
    de Moura, Pollyana Marques
    Hallac, Rami R.
    Seaward, James R.
    Kane, Alex A.
    Aguiar, Marcelo
    Raggio, Ronir
    Gutfilen, Bianca
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 557 - 565
  • [8] Iskanderani D, 2020, ORAL SURG ORAL MED O, P1
  • [9] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint
    Iskanderani, Durer
    Nilsson, Mats
    Alstergren, Per
    Shi, Xie-Qi
    Hellen-Halme, Kristina
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
  • [10] Cone-beam computed tomography: Time to move from ALARA to ALADA
    Jaju, Prashant P.
    Jaju, Sushma P.
    [J]. IMAGING SCIENCE IN DENTISTRY, 2015, 45 (04) : 263 - 265