Structural optimization of V-sector valve cores and adaptability in secondary heating networks

被引:16
作者
Jia, Menglin [1 ]
Li, Zhiwei [1 ]
Jia, Lizhi [1 ]
Liu, Junjie [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
关键词
Secondary heating network; Simulation; Opening shape; Opening variation range; Flow control accuracy; FLOW-CONTROL VALVE; BALL VALVE; FORCES; SPOOL; PERFORMANCE;
D O I
10.1016/j.flowmeasinst.2021.102032
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We analyzed the flow characteristics of a control valve in a secondary heating network and combined the optimization of the valve core structure with a method to solve the actual control problem of the secondary heating network. First, according to the common V-sector ball valve core, another three kinds of different Vsector ball valve cores were designed, and a simulation analysis was carried out using CFD software. By comparing the influence of four different valve core opening shapes on the valve flow characteristic curve, it was found that V3 showed better equal percentage characteristics under the opening range of 50%-100%, which improved the flow control accuracy in the heating pipe network that lacked flow feedback, and the accuracy of the simulation results was verified on the test bench. Based on this, in the different branches of the heating secondary network, the opening variation range of the four valves in actual applications were determined, and the opening variation range of the V3 valve was increased by approximately 10%. The analysis results showed that controlling the proportion of the slender part in the opening shape of the spool can effectively increase the opening range of the control valve in practical applications, thereby improving the flow control accuracy of the heating secondary network and reducing the energy consumption of heating regulation.
引用
收藏
页数:8
相关论文
共 32 条
[11]  
Launder B. E., 1974, Computer Methods in Applied Mechanics and Engineering, V3, P269, DOI 10.1016/0045-7825(74)90029-2
[12]  
Li B., 2018, HVAC, V48, P6
[13]   CFD analysis of the characteristics of a proportional flow control valve with an innovative opening shape [J].
Lisowski, Edward ;
Filo, Grzegorz .
ENERGY CONVERSION AND MANAGEMENT, 2016, 123 :15-28
[14]   Smart energy and smart energy systems [J].
Lund, Henrik ;
Ostergaard, Poul Alberg ;
Connolly, David ;
Mathiesen, Brian Vad .
ENERGY, 2017, 137 :556-565
[15]   Flow investigation around a V-sector ball valve [J].
Merati, P ;
Macelt, MJ ;
Erickson, RB .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03) :662-671
[16]   Flow field simulation and a flow model of servo-valve spool valve orifice [J].
Pan, Xudong ;
Wang, Guanglin ;
Lu, Zesheng .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (10) :3249-3256
[17]  
Qian JY, 2020, NUCL ENG TECHNOL, V52, P2173, DOI [10.1016/j.net.2020.03.008, 10.1016/j.net.2020.03.015]
[18]  
Shi Z., 2009, DIST HEAT, P33
[19]   Reduction of the flow forces in a small hydraulic seat valve as alternative approach to improve the valve characteristics [J].
Simic, Marko ;
Herakovic, Niko .
ENERGY CONVERSION AND MANAGEMENT, 2015, 89 :708-718
[20]   An analytical solution for stability-performance dilemma of hydronic radiators [J].
Tahersima, Fatemeh ;
Stoustrup, Jakob ;
Rasmussen, Henrik .
ENERGY AND BUILDINGS, 2013, 64 :439-446