Intrasession repeatability and intersession reproducibility of peripapillary OCTA vessel parameters in non-glaucomatous and glaucomatous eyes

被引:26
作者
Lee, Jae Chang [1 ]
Grisafe, Dominic J. [1 ]
Burkemper, Bruce [1 ]
Chang, Brenda R. [1 ]
Zhou, Xiao [2 ]
Chu, Zhongdi [2 ]
Fard, Ali [3 ]
Durbin, Mary [3 ]
Wong, Brandon J. [1 ]
Song, Brian J. [1 ]
Xu, Benjamin Y. [1 ]
Wang, Ruikang [2 ]
Richter, Grace M. [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Ophthalmol, 1450 San Pablo St,Suite 4700, Los Angeles, CA 90033 USA
[2] Univ Washington, Bioengn, Seattle, WA 98195 USA
[3] Carl Zeiss Meditec Inc, Dublin, CA USA
基金
美国国家卫生研究院;
关键词
Glaucoma; Imaging; Optic Nerve; COHERENCE TOMOGRAPHY ANGIOGRAPHY; OPEN-ANGLE GLAUCOMA; MACULAR PERFUSION; CAPILLARY DENSITY; OPTIC-NERVE; DETERMINANTS; RETINA;
D O I
10.1136/bjophthalmol-2020-317181
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To compare intrasession repeatability versus intersession reproducibility of the peripapillary vessel parameters using optical microangiography-based optical coherence tomography angiography (OCTA) in non-glaucomatous and glaucomatous eyes. Methods In an observational, longitudinal study, peripapillary OCTA scans were collected to evaluate intrasession repeatability and intersession reproducibility using within-eye coefficient of variation (CVW) and intraclass correlation coefficient (ICC). Images were quantified using a custom research-oriented quantification software calculating vessel area density (VAD) and flux and a commercially developed, clinic-oriented quantification software (Cirrus 11.0, Carl Zeiss Meditec) calculating perfusion density (PD) and flux index (FI). Effect of signal strength on the reliability of OCTA parameters was also evaluated. Results Among 120 non-glaucomatous eyes, intrasession CVW were 4.2% for VAD, 5.3% for flux, 1.5% for PD and 2.0% for FI. The intersession CVW were 6.5% for VAD, 8.0% for flux, 2.0% for PD and 3.2% for FI. The intrasession ICC ranged from 0.928 to 0.945, and intersession ICC ranged from 0.811 to 0.866. From 118 glaucomatous eyes, intrasession CVW was 9.0% for VAD, 10.3% for flux, 1.7% for PD and 2.3% for FI. The intersession CVW was 12.1% for VAD, 14.2% for flux, 2.3% for PD and 3.5% for FI. The intrasession ICC ranged from 0.904 to 0.972, and intersession ICC ranged from 0.855 to 0.955. Signal strength was significantly positively associated with OCTA vessel parameters (p<0.0001) for both groups. Conclusion Peripapillary OCTA vessel parameters had greater intrasession repeatability compared to intersession reproducibility in both non-glaucomatous and glaucomatous eyes. The built-in commercially developed quantification software demonstrated greater agreement than the custom research-oriented quantification software.
引用
收藏
页码:1534 / 1541
页数:8
相关论文
共 39 条
[1]   Microvascular Density in Glaucomatous Eyes With Hemifield Visual Field Defects: An Optical Coherence Tomography Angiography Study [J].
Akagi, Tadamichi ;
Iida, Yuto ;
Nakanishi, Hideo ;
Terada, Noriko ;
Morooka, Satoshi ;
Yamada, Hiroshi ;
Hasegawa, Tomoko ;
Yokota, Satoshi ;
Yoshikawa, Munemitsu ;
Yoshimura, Nagahisa .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 168 :237-249
[2]   Retinal vessel density from optical coherence tomography angiography to differentiate early glaucoma, pre-perimetric glaucoma and normal eyes [J].
Akil, Handan ;
Huang, Alex S. ;
Francis, Brian A. ;
Sadda, Sirinivas R. ;
Chopra, Vikas .
PLOS ONE, 2017, 12 (02)
[3]  
Alnawaiseh M, 2017, RETINA-J RET VIT DIS, V37, P1642, DOI 10.1097/IAE.0000000000001419
[4]   Evaluation of Macular Perfusion in Healthy Smokers by Using Optical Coherence Tomography Angiography [J].
Ayhan, Ziya ;
Kaya, Mahmut ;
Ozturk, Taylan ;
Karti, Omer ;
Oner, F. Hakan .
OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2017, 48 (08) :617-622
[5]   Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables [J].
Bartlett, J. W. ;
Frost, C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) :466-475
[6]  
Bland JM, 1996, BRIT MED J, V313, P744
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[9]   Optical coherence tomography angiography-derived flow density: a review of the influencing factors [J].
Bruecher, Viktoria C. ;
Storp, Jens J. ;
Eter, Nicole ;
Alnawaiseh, Maged .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (04) :701-710
[10]   Systemic Determinants of Peripapillary Vessel Density in Healthy African Americans: The African American Eye Disease Study [J].
Chang, Ryuna ;
Nelson, Andrew J. ;
Letran, Vivian ;
Vu, Brian ;
Burkemper, Bruce ;
Chu, Zhongdi ;
Fard, Ali ;
Kashani, Amir H. ;
Xu, Benjamin Y. ;
Wang, Ruikang K. ;
Varma, Rohit ;
Richter, Grace M. ;
McKean-Cowdin, Roberta ;
Torres, Mina ;
Fairbrother-Crisp, Alicia ;
Choudhury, Farzana ;
Jiang, Xuejuan ;
Adamashvili, Tengiz ;
Lastra, Carlos ;
Corona, Elizabeth ;
Wang, YuPing ;
Douglass, Jacqueline ;
Barrera, Jaimie ;
Linton, Judith .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 :240-247