The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue

被引:332
作者
Antignac, JP
de Wasch, K
Monteau, F
De Brabander, H
Andre, F
Le Bizec, B
机构
[1] INRA, Unite Sous Contrat, ENVN, Lab Etud Residus & Contaminants Aliments,LABERCA, F-44307 Nantes 3, France
[2] State Univ Ghent, Fac Vet Med, Lab Chem Anal, Merelbeke, Belgium
关键词
ion suppression; mass spectrometry; liquid chromatography-mass spectrometry; electrospray ionization; atmospheric pressure chemical ionization; residue analysis;
D O I
10.1016/j.aca.2004.08.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During their first period of development, the liquid chromatography-mass spectrometry techniques were met with great enthusiasm from most end-users. An extended application range, the needlessness of derivatisation step prior to injection, the possibility of reduced sample preparation and high throughput analysis were some of the arguments given in favor of these techniques. Few years and more than thousands applications later, more attention is paid to their adverse aspects and limitations, especially regarding the existence of matrix effects. Such problems are well known for many years and may concern various detection techniques. But ion suppression appears as a kind of matrix effect specifically linked to mass spectrometry that probably represents one of the main source of pitfalls in liquid chromatography-mass spectrometry (LC-MSn). In the actual tendency to promote these techniques for control purposes in the field of residue analysis, it was thought necessary to highlight one of their possible side-effect which may have critical consequences for the analytical results. In this context, the objectives of the present article, which is based on a literature review and additional experiments, were to present the origins and mechanisms of ion suppression, to expose several case studies illustrating its consequences in the field of residue analysis, and finally to propose and comment on some solutions that may overcome this problem. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 26 条
[1]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]   Identification of ractopamine residues in tissue and urine samples at ultra-trace level using liquid chromatography - positive electrospray tandem mass spectrometry [J].
Antignac, JP ;
Marchand, P ;
Le Bizec, B ;
Andre, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (01) :59-66
[3]   ENHANCED SENSITIVITY FOR PEPTIDE-MAPPING WITH ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN THE PRESENCE OF SIGNAL SUPPRESSION DUE TO TRIFLUOROACETIC ACID-CONTAINING MOBILE PHASES [J].
APFFEL, A ;
FISCHER, S ;
GOLDBERG, G ;
GOODLEY, PC ;
KUHLMANN, FE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :177-190
[4]   Quantitative characterization of differential ion suppression on liquid chromatography/atmospheric pressure ionization mass spectrometric bioanalytical methods [J].
Avery, MJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (03) :197-201
[5]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[6]  
2-S
[7]   On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples I. Determination of clenbuterol in urine [J].
Bruins, CHP ;
Jeronimus-Stratingh, CM ;
Ensing, K ;
van Dongen, WD ;
de Jong, GJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 863 (01) :115-122
[8]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[9]   FACTORS AFFECTING ELECTROSPRAY-IONIZATION OF EFFLUENTS CONTAINING TRIFLUOROACETIC-ACID FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
ESHRAGHI, J ;
CHOWDHURY, SK .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3528-3533
[10]   Quantification of the new triketone herbicides, sulcotrione and mesotrione, and other important herbicides and metabolites, at the ng/l level in surface waters using liquid chromatography-tandem mass spectrometry [J].
Freitas, LG ;
Götz, CW ;
Ruff, M ;
Singer, HP ;
Müller, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (02) :277-286