Monte Carlo simulation of expected outcomes with the AcrySof® toric intraocular lens

被引:25
作者
Hill, Warren [1 ]
Potvin, Richard [2 ]
机构
[1] East Valley Ophthalmol, Mesa, AZ 85206 USA
[2] Alcon Labs Inc, Ft Worth, TX 76134 USA
关键词
Monte Carlo Simulation; Astigmatism; Spherical Lens; Corneal Astigmatism; Astigmatic Correction;
D O I
10.1186/1471-2415-8-22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To use a Monte Carlo simulation to predict postoperative results with the AcrySof (R) Toric lens, evaluating the likelihood of over- or under-correction using various toric lens selection criteria. Methods: Keratometric data were obtained from a large patient population with preoperative corneal astigmatism <= 2.50D (2,000 eyes). The probability distributions for toric marking accuracy, surgically induced astigmatism and lens rotation were estimated using available data. Anticipated residual astigmatism was calculated using a Monte Carlo simulation under two different lens selection scenarios. Results: This simulation demonstrated that random errors in alignment, surgically induced astigmatism and lens rotation slightly reduced the overall effect of the toric lens. Residual astigmatism was statistically significantly higher under the simulation of surgery relative to an exact calculation (p < 0.05). The simulation also demonstrated that more aggressive lens selection criteria could produce clinically significant reductions in residual astigmatism in a high percentage of patients. Conclusion: Monte Carlo simulation suggests that surgical variability and lens orientation/rotation variability may combine to produce small reductions in the correction achieved with the AcrySof (R) Toric (R) IOL. Adopting more aggressive lens selection criteria may yield significantly lower residual astigmatism values for many patients, with negligible overcorrections. Surgeons are encouraged to evaluate their AcrySof (R) Toric (R) outcomes to determine if they should modify their individual lens selection criteria, or their default surgically induced astigmatism value, to benefit their patients.
引用
收藏
页数:9
相关论文
共 18 条
[1]  
*ALC LAB INC, PROD INF ACRYSOT TOR
[2]  
Carvalho MJ, 2007, J REFRACT SURG, V23, P499
[3]   Early rotational stability of the longer Staar toric intraocular lens - Fifty consecutive cases [J].
Chang, DF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :935-940
[4]   Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results [J].
Hill, Warren .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :364-367
[5]   Clinical results using the Holladay 2 intraocular lens power formula [J].
Hoffer, KJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1233-1237
[6]   Status of toric intraocular lenses [J].
Horn, Jeffrey D. .
CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) :58-61
[7]   COMPARISON OF THE INDUCED ASTIGMATISM AFTER TEMPORAL CLEAR CORNEAL TUNNEL INCISIONS OF DIFFERENT SIZES [J].
KOHNEN, T ;
DICK, B ;
JACOBI, KW .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04) :417-424
[8]   Assessment of just-noticeable differences for refractive errors and spherical aberration using visual simulation [J].
Legras, R ;
Chateau, N ;
Charman, WN .
OPTOMETRY AND VISION SCIENCE, 2004, 81 (09) :718-728
[9]  
Medicute J, 2008, J CATARACT REFR SURG, V34, P601
[10]   Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas [J].
Narvaez, Julio ;
Zimmerman, Grenith ;
Stulting, R. Doyle ;
Chang, Daniel H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2050-2053