Electrogenerated chemiluminescence biosensor array for the detection of multiple AMI biomarkers

被引:62
作者
Yang, Xiaolin [1 ]
Zhao, Ying [1 ]
Sun, Lijuan [1 ]
Qi, Honglan [1 ]
Gao, Qiang [1 ]
Zhang, Chengxiao [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci Shaanxi Prov, Xian 710119, Shaanxi, Peoples R China
基金
美国国家科学基金会;
关键词
Biosensor array; Electrogenerated chemiluminescence imaging; Myoglobin; Cardiac troponin I; Cardiac troponin T; CARDIAC TROPONIN-I; ACUTE MYOCARDIAL-INFARCTION; ELECTROCHEMILUMINESCENCE IMMUNOSENSOR; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; DNA; MYOGLOBIN; PROTEIN; CHIP; SENSITIVITY;
D O I
10.1016/j.snb.2017.10.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrogenerated chemiluminescence (ECL) biosensor array for the individual and simultaneous detection of multiple biomarkers has been developed at first time on the basis of the aptamer-based biosensor incorporating a versatile signal probe. As principle-of-proof, the acute myocardial infarction (AMI) biomarkers, myoglobin(Myo), cardiac troponin I(cTnI) and cardiac troponin T(cTnT) were chosen as model analytes. The biosensor array was fabricated by self-assembling thiolated specific ssDNA aptamers on the surface of gold electrodes, respectively. After each target analyte was bound to the capture probes and then to each corresponding biotinylated antibody, and finally to the versatile ECL signal probe, ECL signals were recorded using PMT or CCD as a detector. For PMT model, the developed method showed extremely low detection limits for 0.30 ng/mL cTnT, 31 pg/mL Myo, 0.79 pg/mL cTnI. For ECL image model, a biosensor array containing three target biosensors and a control biosensor was found to be highly sensitive, no cross-talking, and accurate towards simultaneous detection of the AMI biomarkers. This work demonstrates that the aptamer-based biosensor array with a versatile signal probe is a promising for ECL simultaneous detection of multi-biomarkers. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 54 条
[1]   Development of a Novel DNA Aptamer Ligand Targeting to Primary Cultured Tumor Endothelial Cells by a Cell-Based SELEX Method [J].
Ara, Mst. Naznin ;
Hyodo, Mamoru ;
Ohga, Noritaka ;
Hida, Kyoko ;
Harashima, Hideyoshi .
PLOS ONE, 2012, 7 (12)
[2]   Detection of cardiac biomarkers using micellar electrokinetic chromatography and a cleavable tag immunoassay [J].
Caulum, Meghan M. ;
Murphy, Brian M. ;
Ramsay, Lauren M. ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5249-5256
[3]   Plastic ELISA-on-a-chip based on sequential cross-flow chromatography [J].
Cho, JH ;
Han, SM ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :793-800
[4]   Electrogenerated chemiluminescence (ECL) 79. Reductive-oxidation ECL of tris(2,2'-bipyridine)ruthenium(II) using hydrogen peroxide as a coreactant in pH 7.5 phosphate buffer solution [J].
Choi, JP ;
Bard, AJ .
ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) :143-150
[5]   On-chip detection of myoglobin based on fluorescence [J].
Darain, Farzana ;
Yager, Paul ;
Gan, Kai Ling ;
Tjin, Swee Chuan .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1744-1750
[6]   Multiplexed Sandwich Immunoassays Using Electrochemiluminescence Imaging Resolved at the Single Bead Level [J].
Deiss, Frederique ;
LaFratta, Christopher N. ;
Symer, Matthew ;
Blicharz, Timothy M. ;
Sojic, Neso ;
Walt, David R. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (17) :6088-+
[7]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[8]   Electrochemical biosensor array for the identification of microorganisms based on lectin-lipopolysaccharide recognition [J].
Ertl, P ;
Mikkelsen, SR .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4241-4248
[9]   Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers [J].
Fathil, M. F. M. ;
Arshad, M. K. Md ;
Gopinath, Subash C. B. ;
Hashim, U. ;
Adzhri, R. ;
Ayub, R. M. ;
Ruslinda, A. R. ;
Nuzaihan, M. M. N. ;
Azman, A. H. ;
Zaki, M. ;
Tang, Thean-Hock .
BIOSENSORS & BIOELECTRONICS, 2015, 70 :209-220
[10]   A novel dual-template molecularly imprinted electrochemiluminescence immunosensor array using Ru(bpy)32+-Silica@Poly-L-lysine-Au composite nanoparticles as labels for near-simultaneous detection of tumor markers [J].
Feng, Xiaobin ;
Gan, Ning ;
Zhou, Jing ;
Li, Tianhua ;
Cao, Yuting ;
Hu, Futao ;
Yu, Hongwei ;
Jiang, Qianli .
ELECTROCHIMICA ACTA, 2014, 139 :127-136